Congratulations – Your TRANE CleanEffectsTM air filtration system is the most advanced, innovative and effective whole house air filtration system on the market today. It is designed to deliver what we call TRANE AirTM throughout your home. It delivers air that is meticulously filtered and cleaned of up to 99.98% of allergens to provide maximum comfort. You and your family can breathe easier than ever before.

32-5038-01

Trane CleanEffects Air Filtration System User Manual

User’s Information

Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTSTM

4

5

3

3

2

6

1

2

3

 

 

 

 

1

Fig. 1

1)Pre-filter - Traps large particles such as hair and lint before they can enter the cell section.

2)Field Charger - Charges the contaminants. Only to be serviced by a qualified technician.

3)Collection Cell (2) - Removes and collects very small impurities from the air.

4)Cabinet - Mounts between the furnace or air handler and return air duct work and houses the collection cells, field charger and pre-filter.

5)Power Door - The solid state power supply components that convert the 24 Volt AC to the high-voltage, direct current required to power the field charger and cells. Allows access to the collection cells, field charger and prefilter.

6)24 Volt Power Cable

DISPLAY FEATURES

The air cleaner display (Fig. 2) has the following functions:

LED and Pre-filter lights display the operating status of the air cleaner, indicating when to clean the pre-filter or collection cells.

The LED display is also used in the set-up mode, see page 5.

Fig. 2

32-5035-02

2

SEQUENCE OF OPERATION

You will need to turn off your air cleaner to clean the filters. After cleaning, turn on the unit by pressing and releasing the Power button. The backlit Power and Filter Reset button will illuminate along with first green LED indicating power is present. When the indoor fan is operating the first green LED will slowly flash. This indicates the field charger and collection cells have power and the unit is operating normally. There is a slight time delay between the indoor fan starting and LED flashing.

NOTE: There is a 10 minute delay after the indoor fan operates, before the air cleaner starts to operate, each time the power to the air cleaner is turned off/on. This can be bypassed by going into and then out of the

Set-Up Mode.

Your air filtration system only operates when the air is circulating through the indoor unit.

The air filtration system is most effective at cleaning the air if the fan operates continuously. Most thermostats have a setting that will permit continuous fan operation. Continuous fan mode during Cooling operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.

In normal operation, the air cleaner may make a slight sound as the air passes through it and is cleaned. In some applications, you may notice this sound coming from the return air vent(s). If desired, this sound level can be reduced with minimal impact on air cleaning efficiency by reducing the power setting of the field charger in the set-up mode (see p.5-6).

MAINTENANCE

In normal use, the pre-filter should be cleaned every 2 months and the collection cells should be cleaned every 6 months. The field charger should be cleaned only by a qualified service technician annually.

User’s Information

! CAUTION

This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that may result in flashover or risk of fire.

The field charger should only be removed and cleaned by authorized service personnel.

CLEANING INDICATORS

Both the pre-filter and the collection cells have timers which monitor actual run time of the unit and indicate when cleaning is required. The time between cleaning can be adjusted based on your preferences and conditions in the home. See the SET-UP MODE section on page 5 to change the filter timers.

The red PRE-FILTER light will illuminate when it is time to clean the pre-filter.

The clean/dirty light bar indicator will illuminate as the system cleans the air in your home. The lights will progress from green to yellow then to red. When the last red indicator is flashing it is time to clean the collection cells.

REMOVING FILTERS FOR CLEANING

♦ Turn the furnace/ air conditioning system off at the thermostat.

! CAUTION

High voltage is present within the air cleaner for operation. Before removing the door, turn the power off and wait at least 15 seconds to allow voltage to discharge.

♦ Turn off power by pushing and holding the power button for approximately three seconds until all the LED’s illuminate. Release the power button. The LED’s will remain on until the voltage has discharged and it is safe to remove the door.