Installation Instructions

Over The Range Microwave Oven

BEFORE YOU BEGIN (Read these instructions completely and carefully.)

IMPORTANT Save these instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer

- Be sure to leave these instructions with the Consumer.

Note to Consumer

- Keep these instructions for future reference.

Skill level

- Installation of this appliance requires basic mechanical and electrical

 

 

skills.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

READ CAREFULLY. KEEP THESE INSTRUCTIONS.

SMH1816_XAA-DE68-03943A-03-EN.indd 1

 

 

2/4/2014 10:03:26 AM

 

 

 

 

 

 

Contents

General information

Important safety instructions . . . .

.

3

Electrical requirements . . . . . .

.

3

Hood exhaust

 

4

Damage - Shipment/Installation

 

6

Parts included . . . . . . . . . .

 

6

Tools you will need . . . . . . . .

.

7

Mounting space

 

7

Step-by-step installation guide

1. Placement of the mounting plate

8

A.Removing the microwave oven from the carton/Removing the mounting plate . . 8

B. Finding the wall studs . . . . . . . 8

C. Determining wall plate location under your cabinet . . . . . . . . . . . . 9

D. Aligning the wall plate . . . . . .

. 10

2. Ventilation types (choose a, b or c)

11

A.Outside top exhaust (vertical duct) . . 12

A1. Installation procedure for exhaust adaptor and proper damper operation check . . . . . . . . . . . 12

A2. Adjust the exhaust adaptor . . . 12

B.Recirculating (non-vented ductless) . . 12

B1. Adapting the microwave blower for

 

recirculation . . . . . . . .

12

B2. Installing the charcoal filter . . .

13

C. Outside back exhaust (horizontal duct)

14

C1. Adapting the microwave blower for

 

outside back exhaust . . . . .

14

3. Installation . . . . . . . . . . . 15

A. Preparing the rear wall for outside back exhaust . . . . . . . . . . . . 15

B.Attach the mounting plate to the wall . 15

C.Use the top cabinet template to prepare

the top cabinet . . . . . . . . . 16 D. Mount the microwave oven . . . . . 16

E.Connecting ductwork for outside top exhaust . . . . . . . . . . . . 17

4.Before you use your microwave . . . 18

 

2

SMH1816_XAA-DE68-03943A-03-EN.indd 2

2/4/2014 10:03:26 AM

General information

Important safety instructions

This product requires a three-prong grounded outlet. The installer must perform a ground continuity check on the power outlet box before beginning the installation to insure that the outlet box is properly grounded. If not properly grounded, or if the outlet box does not meet

electrical requirements noted (under ELECTRICAL REQUIREMENTS), a qualified electrician should be employed to correct any deficiencies.

CAUTION: For personal safety, remove house fuse or open circuit breaker before beginning installation to avoid severe or fatal shock injury.

CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 69 pound product, plus additional oven loads of up to 50 pounds or a total weight of 109 pounds.

CAUTION: For personal safety, this product cannot be installed in cabinet arrangements such as an island or a peninsula. It must be mounted to BOTH a top cabinet AND a wall.

NOTE: For easier installation and personal safety, it is recommended that two people install this product.

IMPORTANT – PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.

Insureproperproper

groundexistsexists before use. before use

The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.

You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

If you have a standard two-prong wall receptacle, it is very important to have it replaced with a properly grounded threeprong wall receptacle, installed by a qualified electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.

Electrical requirements

Product rating is 120 volts AC, 60 Hertz, 14.5 amps and 1.7 kilowatts.This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 15 ampere branch circuit single grounded outlet. The outlet box should be located in the cabinet above the microwave oven. The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code.

3

SMH1816_XAA-DE68-03943A-03-EN.indd 3

 

 

2/4/2014 10:03:26 AM

 

 

 

 

 

 

General information

Hood exhaust

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to recirculate the air back into the room, proceed to page 11.

OUTSIDE TOP EXHAUST (EXAMPLE ONLY)

The following chart contains an example of one possible ductwork installation.

 

 

DUCT PIECES

EQUIVALENT

x

NUMBER

=

EQUIVALENT

 

 

LENGTH

USED

LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof Cap

24 ft.

x

(1)

=

24 ft.

 

 

 

 

 

 

 

 

 

 

 

 

12 ft. Straight Duct

12 ft.

x

(1)

=

12 ft.

 

 

 

 

 

 

(6˝ Round)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rectangular-to-

 

 

 

 

 

 

 

 

Round Transition

5 ft.

x

(1)

=

5 ft.

 

 

 

Adaptor*

 

 

 

 

 

 

 

 

 

 

 

 

 

Equivalent lengths of duct pieces are based on actual tests

Total Length

=

41 ft.

and reflect requirements for good venting performance with

any vent hood.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.

OUTSIDE BACK EXHAUST (EXAMPLE ONLY)

The following chart contains an example of one possible ductwork installation.

 

 

DUCT PIECES

EQUIVALENT

x

NUMBER

=

EQUIVALENT

 

 

LENGTH

USED

LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Cap

40 ft.

x

(1)

=

40 ft.

 

 

 

 

 

 

 

 

 

 

 

 

3 ft. Straight Duct (3 ¼˝

3 ft.

x

(1)

=

3 ft.

 

 

 

 

 

 

x 10˝ Rectangular)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 ° Elbow

10 ft.

x

(2)

=

20 ft.

 

 

 

 

 

 

 

 

Equivalent lengths of duct pieces are based on actual tests

Total Length

=

63 ft.

and reflect requirements for good venting performance with

any vent hood.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

 

4

SMH1816_XAA-DE68-03943A-03-EN.indd 4

2/4/2014 10:03:27 AM

General information

NOTE: If you need to install ducts, note that the total duct length of 3 ¼˝ x 10˝ rectangular or 6˝ diameter round duct should not exceed 140 equivalent feet.

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

NOTE: It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.

Exhaust connection:

The hood exhaust has been designed to mate with a standard 3 ¼˝ x 10˝ rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6˝ diameter duct.

Maximum duct length:

For satisfactory air movement, the total duct length of 3 ¼˝ x 10˝ rectangular or 6˝ diameter round duct should not exceed 140 equivalent feet.

Elbows, transitions, wall and roof

caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the equivalent length in feet of some typical ducts.

 

 

 

DUCT PIECES

EQUIVALENT

x

NUMBER

=

EQUIVALENT

 

 

 

LENGTH

USED

LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rectangular-to-Round

5 ft.

x

(

)

=

ft.

 

 

 

Transition Adaptor*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Cap

40 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

90 ° Elbow

10 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

45 ° Elbow

5 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

90 ° Elbow

25 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

45 ° Elbow

5 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof Cap

24 ft.

x

(

)

=

ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

Straight Duct 6˝ Round or 3 ¼˝

1 ft.

x

(

)

=

ft.

 

 

 

 

 

 

x 10˝ Rectangular

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Ductwork

=

ft.

 

 

 

 

 

 

 

 

 

 

*IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using tin snips, in order to allow free movement of the damper.

Equivalent lengths of duct pieces are based on actual tests and reflect the requirements for good venting performance with any vent hood.

5

SMH1816_XAA-DE68-03943A-03-EN.indd 5

 

 

2/4/2014 10:03:27 AM

 

 

 

 

 

 

Samsung SMH2117S/XAA, SMH1926S/XAA, SMH1816S/XAA, SMH1816W/XAA, ME21F606MJT/AA Installation Guide

General information

Damage - Shipment/Installation

If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.

If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between the customer and installer.

Parts included

 

HARDWARE PACKET

 

PART

QUANTITY

Wood Screws

1

(¼˝ x 2˝)

 

Toggle Bolts

 

(and wing nuts)

2

(3/16˝ x 3˝)

 

Self-aligning

 

Machine Screws

2

(¼˝ - 28 x 3 ¼˝)

 

Nylon Grommet

1

(for metal cabinets)

 

You will find the installation hardware contained in a packet with the unit. Check to make sure you have all these parts.

NOTE: Some extra parts are included.

ADDITIONAL PARTS

 

PART

QUANTITY

 

Top Cabinet

1

TOP CABINET TEMPLATE

Template

REAR WALL TEMPLATE

Rear Wall Template

1

 

Installation

1

 

Instructions

 

 

 

Separately Packed

2

 

Grease Filter

 

 

 

Exhaust adaptor

1

 

6