SAMSUNG M1711NR Service Manual

4 (1)

MICROWAVE OVEN

M1711NR

SERVICE Manual

MICROWAVE OVEN

BWT

CONTENTS

1.Precaution

2.Specifications

3.Operating Instructions

4.Disassembly and Reassembly

5.Alignment and Adjustments

6.Troubleshooting

7.Exploded Views and Parts List

8.Schematic Diagrams

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

(a)Do not operate or allow the oven to be operated with the door open.

(b)Make the following safety checks on

all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary:

(1)Interlock operation,

(2)proper door closing,

(3)seal and sealing surfaces (arcing, wear, and other damage),

(4)damage to or loosening of hinges and latches,

(5)evidence of dropping or abuse.

(c)Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e)A Microwave leakage check to verify compliance with the Federal performance standard should be performed on each oven prior to release to the owner.

1. Precaution

Follow these special safety precautions. Although the microwave oven is completely safe during ordinary use, repair work can be extremely hazardous due to possible exposure to microwave radiation, as well as potentially lethal high voltages and currents.

1-1 Safety precautions ( )

1.All repairs should be done in accordance with the procedures described in this

manual. This product complies with Federal Performance Standard 21 CFR. Subchapter J(DHHS).

2.Microwave emission check should be performed to prior to servicing if the oven is operative.

3.If the oven operates with the door open : Instruct the user not to operate the oven and contact the manufacturer and the center for devices and radiological health immediately.

4.Notify the Central Service Center if the microwave leakage exceeds 5 mW/cm2.

5.Check all grounds.

6.Do not power the MWO from a "2-prong"

AC cord. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.

7.When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.

8.Make sure that there are no cabinet openings through which people --particularly

children --might insert objects and contact dangerous voltages. Examples: Lamp hole, ventilation slots.

9.Inform the manufacturer of any oven found to have emission in excess of 5 mW/cm2 , Make repairs to bring the unit into compliance at no cost to owner and try to determine cause.

Instruct owner not to use oven until it has been brought into compliance.

CENTRAL SERVICE CENTER

10.Service technicians should remove their watches while repairing an MWO.

11.To avoid any possible radiation hazard, replace parts in accordance with the wiring diagram. Also, use only the exact replacements for the following parts: Primary and secondary interlock switches, interlock monitor switch.

12.If the fuse is blown by the Interlock Monitor Switch: Replace all of the following at the same time: Primary, door sensing switch and power relay, as well as the Interlock Monitor Switch. The correct adjustment of these switches is described elsewhere in this manual. Make sure that the fuse has the correct rating for the particular model being repaired.

13.Design Alteration Warning:

Use exact replacement parts only, i.e., only those that are specified in the drawings and parts lists of this manual. This is especially important for the Interlock switches, described above. Never alter or add to the mechanical or electrical design of the MWO. Any design changes or additions will void the manufacturer's warranty. Always unplug the unit's AC power cord from the AC power source before attempting to remove or reinstall any component or assembly.

14.Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.

15.Some semiconductor ("solid state") devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs). Examples include integrated circuits and field-effect transistors.

Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground.

16.Always connect a test instrument's ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument's ground lead last.

- 1 -

1-2 Special Servicing Precautions (Continued)

17.When checking the continuity of the witches or transformer, always make sure that the power is OFF, and one of the lead wires is disconnected.

18.Components that are critical for safety are indicated in the circuit diagram by shading, or .

19.Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.

1-3 Special High Voltage Precautions

1. High Voltage Warning

H. V. Capacitor

Do not attempt to measure any of the high

 

voltages --this includes the filament voltage

 

of the magnetron. High voltage is present

 

during any cook cycle.

 

Before touching any components or wiring,

 

always unplug the oven and discharge the

 

high voltage capacitor (See Figure 1-1)

 

2. The high-voltage capacitor remains charged

 

about 30 seconds after disconnection. Short

 

the negative terminal of the high-voltage

 

capacitor to to the oven chassis. (Use a

 

screwdriver.)

 

3. High voltage is maintained within specified

H. V. Diode

limits by close-tolerance, safety-related

Short

components and adjustments. If the high

 

voltage exceeds the specified limits, check

Touch chassis ground first then short to the high

each of the special components.

 

voltage capacitor terminal by using screwdriver or

 

jumper wire.

PRECAUTION

There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near these circuits with the oven energized.

DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.

Fig. 1-1 Discharging High Voltage Capacitor

PRECAUTION

Never touch any circuit wiring with your hand nor with uninsulated tool during operation.

PRECAUTION

Servicemen should remove their watches whenever working close to or replacing the magnetron.

- 2 -

2. Specifications

2-1 Table of Specifications

TIMER

35 MINUTES

POWER SOURCE

230V ~ 50Hz

POWER CONSUMPTION

MICROWAVE : 1,150W

OUTPUT POWER

100W / 800W

 

(IEC-705 TEST PROCEDURE)

OPERATING FREQUENCY

2,450MHz

 

MAGNETRON

OM75S(31)

COOLING METHOD

COOLING FAN MOTOR

OUTSIDE DIMENSIONS

489(W) x 275(H) x 374(D)

OVEN DIMENSIONS

306(W) x 211(H) x 320(D)

SHIPPING DIMENSIONS

557(W) x 329(H) x 451(D)

SHIPPING WEIGHT APPROX.

NET

13.5kg

 

 

 

- 3 -

SAMSUNG M1711NR Service Manual

3. Operating Instructions

3-1 Control Panel

3-2 Features & External Views

VENTILATION HOLES

LIGHT

VARIABLE COOKING

 

 

 

POWER CONTROL KNOB

 

 

 

 

TURNTABLE

DOOR LATCHES

DOOR

 

 

TIMER KNOB

COUPLER

 

ROLLER RING

OPEN DOOR

SAFETY

PUSH BUTTON

INTERLOCK HOLES

2 57 mm

206mm

342mm

 

489mm

374mm

 

 

 

 

 

 

 

 

 

 

 

- 4 -

4. Disassembly and Reassembly

4-1 Replacement of Magnetron, Motor Assembly and Lamp

Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which are contained in one assembly).

1.Disconnect all lead wires from the magnetron and lamp.

2.Remove a screw securing air cover.

3.Remove the air cover.

4.Remove screws securing the magnetron to the wave guide.

5.Take out the magnetron very carefully.

6.Remove nuts from the back panel.

7.Take out the fan motor.

8.Remove the oven lamp by rotating to pull out from hole of air cover.

NOTE1: When removing the magnetron, make sure that its antenna does not hit any adjacent parts, or it may be damaged.

NOTE2: When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition.

4-2 Replacement of High Voltage Transformer

1.Discharge the high voltage capacitor.

2.Disconnect all the leads.

3.Remove the mounting bolts.

4.Reconnect the leads correctly and firmly.

PRECAUTION

Servicemen should remove their watches whenever working close to or replacing the magnetron.

PRECAUTION

There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near these circuits with the oven energized.

DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.