Omron BP755 User Manual

4 (2)

INSTRUCTION MANUAL

Automatic Blood Pressure Monitor

with ComFitCuff

Model BP755

BP755

®

ENGLISH ESPAÑOL

Before Using the Monitor

 

CONTENTS

 

Before Using the Monitor

 

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Operating Instructions

 

Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Irregular Heartbeat Symbol () . . . . . . . . . . . . . . . . . . . . . . .10

Movement Error Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . .10

Average Value Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . .10

Heartbeat Symbol/Hypertension Indicator ( ) . . . . . . . . . . .11

Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Care and Maintenance

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . .31

FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

2

INTRODUCTION

Thank you for purchasing Omron® BP755 IntelliSense® Automatic Blood Pressure Monitor with the ComFitCuff.

Fill in for future reference.

DATE PURCHASED: __________________

SERIAL NUMBER: ____________________

Staple your purchase receipt here

Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.

The BP755 comes with the following components:

• Monitor

• ComFitCuff

 

• AC Adapter

• Storage Case

• Quick Start Guide

• Instruction Manual printed in English and Spanish

The BP755 IntelliSense® Automatic Inflation Blood Pressure Monitor is intended for home use.

SAVE THESE INSTRUCTIONS

3

SAFETY INFORMATION

To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

Indicates a potentially hazardous situation

WARNING which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation

which, if not avoided, may result in minor or CAUTION moderate injury to the user or patient or

damage to the equipment or other property.

OPERATING THE DEVICE

Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.

The monitor is not intended to be a diagnostic device.

If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.

Read all of the information in the instruction manual and any other literature in the box before operating the unit.

4

SAFETY INFORMATION

OPERATING THE DEVICE (continued)

This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.

Read the Special Conditions section (page 24) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.

Operate the device only as intended. Do not use the device for any other purpose.

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Do not use a cellular phone near the device. It may result in an operational failure.

Use only authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.

Use only 1.5 V “AA” alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.

RISK OF ELECTRICAL SHOCK

Do not plug or unplug the power cord into the electrical outlet with wet hands.

Do not overload power outlets. Plug the device into the appropriate voltage outlet.

5

SAFETY INFORMATION

CARE AND MAINTENANCE

Do not subject the monitor to strong shocks, such as dropping the unit on the floor.

Do not submerge the device or any of the components in water.

Store the device and the components in a clean, safe location.

Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the unit or components.

6

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:

1.Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.

2.Stress raises blood pressure. Avoid taking measurements during stressful times.

3.Measurements should be taken in a quiet place.

4.Remove tight-fitting clothing from your left arm.

5.Sit on a chair with your feet flat on the floor. Rest your left arm on a table so that the cuff is at the same level as your heart.

6.Remain still and do not talk during the measurement.

7.Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.

8.Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.

7

Omron BP755 User Manual

Operating Instructions

KNOW YOUR UNIT

Main Unit:

Display

Battery Compartment

B

 

P7

55

®

 

 

Start/Stop

 

Button

Memory Buttons

Air Jack

Date/Time Setting Button ( )

AC Adapter Jack

 

Components:

 

Thumb Grip

Air Tube

 

Air Plug (Connects to Air Jack)

Arm Cuff

Housing

INSTRUCTION MANUAL

Automatic Blood Pressure Monitor

with ComFit Cuff

Model BP755

Cord

AC Adapter

Instruction Manual

Storage Case

Quick Start Guide

8

UNIT DISPLAY

Systolic Blood Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diastolic Blood Pressure

 

 

 

 

 

 

 

 

 

 

Heartbeat Symbol/

 

 

 

 

 

 

 

 

 

 

Memory Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hypertension Indicator

Average Value Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulse Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Movement Error Symbol

 

 

 

 

 

 

 

 

 

 

 

Deflation Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Low Indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date/Time Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Irregular Heartbeat Symbol

 

 

 

 

 

 

9

DISPLAY SYMBOLS

IRREGULAR HEARTBEAT SYMBOL ()

When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol () will appear on the display with the measurement values.

An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.

If the irregular heartbeat symbol () displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.

Normal Heartbeat

Pulse

Blood pressure

Irregular Heartbeat

Short Long

Pulse

Blood pressure

MOVEMENT ERROR SYMBOL ( )

The Movement Error Symbol ( ) is displayed if you move your body during the measurement. Please remove the arm cuff, and wait

2-3 minutes, reapply the arm cuff and take another measurement.

AVERAGE VALUE SYMBOL ( )

The Average Value Symbol ( ) is displayed when you press the Memory button. The most recent average reading appears on the display screen.

10

DISPLAY SYMBOLS

HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ( )

TAKING A MEASUREMENT

The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat.

When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or above 85 for the Diastolic Blood Pressure value.

USING THE MEMORY FUNCTION

The Heartbeat Symbol ( ) flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and/or above 85 for the Diastolic Blood Pressure value.

11

Loading...
+ 25 hidden pages