LiftMaster CSW24V User Manual

0 (0)

USER’S GUIDE

V E H I C U L A R S L I D E / S W I N G G A T E O P E R A T O R S

CSL24V ™ & CSL24VH ™ CSW24V ™ & CSW24VH ™

Your model may look different than the model illustrated in this user’s guide.

Please contact your authorized LiftMaster dealer for all of your service needs.

Installation Date

www.liftmaster.com

Thank you for purchasing a LiftMaster gate operator. Our operators are designed to meet or exceed UL325 safety standards and requirements and are quality manufactured for years of safe and reliable service. Think LiftMaster for all of your Access Control needs.

OPERATION

RESET SWITCH/MANUAL DISCONNECT

The reset switch is located on the front of the operator and serves several functions. When referring to “toggling” the reset switch it means pressing the reset switch to the RESET/DISCONNECT position, then back to the NORMAL OPERATION position.

Toggling the reset switch will stop a moving gate during a normal open/close cycle, like a stop button. The operator does not need to be reset after doing this. The reset switch will disable the gate in the present position and will energize the solenoid lock for two minutes and disable the maglock for two minutes.

MODEL CSL24V SLIDE GATE OPERATOR

Press the reset switch to RESET/ DISCONNECT to allow the gate to be opened and closed manually. To resume normal operation press the reset switch to NORMAL OPERATION.

MODEL CSW24V SWING GATE OPERATOR

Press the reset switch to RESET/ DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down.

Manual Disconnect

Handle

NORMAL OPERATION

RESET/DISCONNECT

NORMAL OPERATION

RESET/DISCONNECT

1

LiftMaster CSW24V User Manual

OPERATION

OPERATOR ALARM

If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset. If a command is given after the initial 5 minutes the operator will beep.

When the inherent force of the operator (RPM/current sensor) detects the following (twice consecutively) the alarm will sound (up to 5 minutes) and the operator will need to be reset:

The gate is hitting a wall or vehicle.

The gate does not meet specifications.

Debris is on the gate's track such as mud, rocks, dirt, etc. (Slide Only)

Gate hinges are too tight or broken and the gate is not moving freely. (Swing Only)

The gate has one or more broken axles or wheels. (Slide Only)

A foreign object is on the gate frame while the gate is moving. (Swing Only)

The gate wheel is off the gate rail. (Slide Only)

The gate is moving and a car pushes the gate.

(Swing Only)

The operator arm or gate is incorrectly installed. (Swing Only)

The gate hits the driveway, curb or other, and gets stuck or bent in an awkward position.

(Swing Only)

Remove any obstructions. Toggle the reset switch to shut off the alarm and reset the operator. After the operator is reset, normal functions will resume.

REMOTE CONTROL

Once the remote control has been programmed operator will operate as follows:

When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate. When the gate is in the open position, activation of the remote control button will close the gate. If the

remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate.