Lift-master BJ Manual

5 (2)

Lift-Masterâ

A Unit of Duchossois Industries, Inc.

 

The Chmaberlain Group, Inc.

The Professional Line

845 Larch Avenue, Elmhurst, Illinois 60126

OWNERS MANUAL

MODEL BJ

BELT JACK

SERIES B

WIRING

TYPE COMMERCIAL DOOR OPERATOR LISTED

Lift-master BJ Manual

TYPE

STATION

NUMBER

FUNCTION

B

3 Button

453365

Momentary contact to open, close and stop.

B1

3 Button

453639

Momentary contact to open, close and stop plus wiring for sensing

 

 

 

device to stop.

B2

3 Button

453642

Momentary contract to open, close and stop plus wiring for sensing

 

 

 

device to reverse and auxiliary devices to open and close with

 

 

 

override.

C

3 Button

453636

Momentary contact to open and stop with constant pressure to

 

 

 

close.

C1

3 Button

453640

Momentary contact to open and stop with constant pressure to close

 

 

 

and wiring for sensing device to stop.

C2

3 Button

453643

Momentary contact to open and stop with constant pressure to

 

 

 

close.

D

2 Button

453641

Constant pressure to open and close.

D1

2 Button

453641

Constant pressure to open and close with wiring for sensing device

 

 

 

to stop.

E

2 Button

453638

Momentary contact to open and constant pressure to close. Release

 

 

 

of close button will cause door to reverse (rollback feature).

E2

2 Button

453644

Momentary contact to open with open override and constant

 

 

 

pressure to close.

S

1 Button

453645

Momentary contact to open and close plus wiring for sensing device

 

 

 

to reverse, auxiliary devices to open and close, with open override.

T

3 Button

453646

Momentary contact to open, close and stop with open override and

 

 

 

timer to close. Open button may be connected to activate timer if

 

 

 

desired. Auxiliary controls may be connected to open and activate to

 

 

 

close or to open and close, without activating timer.

ST

1 Button

453647

“T” type wiring with single button instead of three button operation.

 

 

 

(See “S” type wiring.)

TS

3 Button

453648

momentary contact open, close and stop with open override and

 

 

 

timer to close. EVERY device that causes door to open will activate

 

 

 

timer to close including sensing device to reverse. Timer may be

 

 

 

deactivated until next opening signal is received by depressing stop

 

 

 

button after door has reached open position or permanently by use

 

 

 

of optional timer defeat switch. Photo-cell or loop detector not

 

 

 

recommended for use as a sensing device to reverse with this wiring

 

 

 

type.

STS

1 Button

453649

‘TS” type wiring with single button instead of three button operation.

 

 

 

(See ‘S” type wiring.)

Notes: 1. External interlocks may be wired into all wiring types.

2.Auxiliary devices are any devices that have only one set of contacts. Examples are: photo-cell, loop detector, pneumatic orelectric treadles, residential radio controls, one button stations, pull cords\, etc.

3.open override means that the door may be reversed while closing by activating an opening device without the need to use the step button first.

Loading...