WIRING
TYPE COMMERCIAL DOOR OPERATOR LISTED
TYPE |
STATION |
NUMBER |
FUNCTION |
B |
3 Button |
453365 |
Momentary contact to open, close and stop. |
B1 |
3 Button |
453639 |
Momentary contact to open, close and stop plus wiring for sensing |
|
|
|
device to stop. |
B2 |
3 Button |
453642 |
Momentary contract to open, close and stop plus wiring for sensing |
|
|
|
device to reverse and auxiliary devices to open and close with |
|
|
|
override. |
C |
3 Button |
453636 |
Momentary contact to open and stop with constant pressure to |
|
|
|
close. |
C1 |
3 Button |
453640 |
Momentary contact to open and stop with constant pressure to close |
|
|
|
and wiring for sensing device to stop. |
C2 |
3 Button |
453643 |
Momentary contact to open and stop with constant pressure to |
|
|
|
close. |
D |
2 Button |
453641 |
Constant pressure to open and close. |
D1 |
2 Button |
453641 |
Constant pressure to open and close with wiring for sensing device |
|
|
|
to stop. |
E |
2 Button |
453638 |
Momentary contact to open and constant pressure to close. Release |
|
|
|
of close button will cause door to reverse (rollback feature). |
E2 |
2 Button |
453644 |
Momentary contact to open with open override and constant |
|
|
|
pressure to close. |
S |
1 Button |
453645 |
Momentary contact to open and close plus wiring for sensing device |
|
|
|
to reverse, auxiliary devices to open and close, with open override. |
T |
3 Button |
453646 |
Momentary contact to open, close and stop with open override and |
|
|
|
timer to close. Open button may be connected to activate timer if |
|
|
|
desired. Auxiliary controls may be connected to open and activate to |
|
|
|
close or to open and close, without activating timer. |
ST |
1 Button |
453647 |
“T” type wiring with single button instead of three button operation. |
|
|
|
(See “S” type wiring.) |
TS |
3 Button |
453648 |
momentary contact open, close and stop with open override and |
|
|
|
timer to close. EVERY device that causes door to open will activate |
|
|
|
timer to close including sensing device to reverse. Timer may be |
|
|
|
deactivated until next opening signal is received by depressing stop |
|
|
|
button after door has reached open position or permanently by use |
|
|
|
of optional timer defeat switch. Photo-cell or loop detector not |
|
|
|
recommended for use as a sensing device to reverse with this wiring |
|
|
|
type. |
STS |
1 Button |
453649 |
‘TS” type wiring with single button instead of three button operation. |
|
|
|
(See ‘S” type wiring.) |
Notes: 1. External interlocks may be wired into all wiring types.
2.Auxiliary devices are any devices that have only one set of contacts. Examples are: photo-cell, loop detector, pneumatic orelectric treadles, residential radio controls, one button stations, pull cords\, etc.
3.open override means that the door may be reversed while closing by activating an opening device without the need to use the step button first.