Bosch Residential Geothermal Heat Pump, SM, SM 48, CDI User Manual

0 (0)
Bosch Residential Geothermal Heat Pump, SM, SM 48, CDI User Manual

CDI series

Engineering

 

 

 

 

Submittal

 

 

Model SM

 

 

 

Sheet

 

 

Residential Geothermal Heat Pump

 

 

 

 

 

 

 

 

 

 

Overview and Certifications

Standard Features, Factory Installed Options, and Field Installed Accessories

Standard Features

White Pre-Painted Sheet Metal Cabinets

No visible screws

Appliance White for a Clean - Durable Look

Door Handles - for Easy Removal for Service

LCD Display - for Easy View of Unit Operation

High Efficiency

Up to 32.0 EER @ PL GLHP

Up to 22.0 EER @ FL GLHP

Compliant with Energy Start Tier 3

Electronically Communicated Motors

Your choice of Variable Speed ECM or Fix-Torque ECM

Constant Torque High Efficiency ECM

Constant CFM Variable Speed High Efficient ECM

Field Configurable

Supply Air Connection - Top, Side, and Back (Kit required)

Return Air Connection - Right or Left Side

Electrical Control Box Relocation

Patent: Blower Configurability

Can Also Order Right Hand Or Left Hand Return From Factory

Closed Cell (Fiber Free) Insulation

Less than 2% Air Leakage Rate

1 of 42

Improved Indoor Air Quality

Sound Ratings as Low as 52 DBA

Patent: Floating Base Pan

Reliability - Durability - Serviceability

Tin Plated Evaporator Coil

Alert Communicating Circuit Board

Electronic Circuit Board

LCD Display - for Easy View of Unit Operation

Low Pressure Switch Protection

High Pressure Switch Protection

Alarm Output

Condensate overflow protection

Anti-Short Cycling

5 minute Delay

Low Pressure Bypass at Start Up

Random Start of Unit

Brown Out Protection

Evaporator Freeze Protection

Water Coil/Coaxial Coil/Condenser Freeze Protection

Standard Warranty

10 Year All Parts Limited Warranty

10 Year Labor Limited Warranty

Bosch Thermotechnology Corp.

Londonderry, NH • Ft. Lauderdale, FL

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

SM Series

Residential Geothermal Heat Pumps

Standard Features, Factory Installed Options, and Field Installed Accessories continued..

Factory Installed Options

Cupro-nickel Coil:

Recommended in conditions anticipating moderate scale formation or in brackish water.

Internal Electric Heat:

Can be factory mounted or field installed. Choices include 5, 10, 15, or 20 kilowatt back up or an emergency heater depending on the size of the geothermal heat pump.

Domestic Hot Water Heat Recovery Package:

Used to heat domestic hot water using the wasted heat from the hot compressed gas of the compressor.

Dehumidification:

Lower the humidity in your home allowing you to turn up the thermostat in the summer.

SmartStart:

A factory installed start up device that improved start up effieciency as much as 65% and helps reduce wear and tear on the compressor during start up.

Field Installed Accessories

Thermostats:

Bosch thermostats are fully customized to meet your individual needs. True Communicating thermostat that displays the alert messages without having to go to the unit.

DDC Control:

Field Conversion Kit

 

 

Bosch Thermotechnology Corp.

2 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

Model Nomenclature

SM 48 - 1 VT C - F L T T T A - X H G X X X X X D 7 X X X X 5

1-2 3-5 6 7 8-9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

MODEL:

SM

NOMINAL CAPACITY: 024

036

048

060

070

ELECTRICAL CONFIGURATION: 1 - 208-230/1/60

CABINET CONFIGURATION:

VT - Vertical

HZ - Horizontal

CF - Counterflow

COAX OPTIONS:

C - Copper

N - Cupro-nickel*

*Only coils are cupro-nickel.

WATER CONNECTIONs:

F - Front (HZ Only)

S - Side

RETURN AIR CONFIGURATION:

L - Left

R - Right

DISCHARGE AIR LOCATION:

T - Top (VT only)

E - End Blow (HZ only)

B - Bottom (CF only)

FAN/MOTOR OPTION:

A - Constant CFM Motor

T - Constant Torque Motor

AIR COIL:

T - Tinned

REVISION LEVEL:

A - Rev A

AIR FILTRATION:

5 - MERV13 - 2" w/ 4-Side Filter Rack

OPEN:

X - None

ECONOMIZER:

X - None

WATER FLOW CONTROL OPTIONS:

X - None

CONTROLS:

X - Standard

TRANSFORMER:

7 - 75VA

REFRIGERATION:

X - None

H - Hot Gas Reheat On/Off

1 - Heat Recovery Package

ELECTRICAL OPTIONS:

A - EMS Relay

E - Pump/valve Relay

H - Flow Proving Switch

N - Comfort Alert Module

S - Start Assist

X - As default for non-used electrical codes

APPLICATION:

G - EXTENDED RANGE (Geothermal)

CABINET CONSTRUCTION:

H - Painted Steel / 1/2" Closed Cell Foam

ELECTRIC HEAT:

X

- None

A

- 5 kW

C- 10 kW

D- 15 kW

E- 20 kW

 

 

Bosch Thermotechnology Corp.

3 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

Physical Data

Description

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM024

 

 

 

 

 

SM036

 

 

 

 

 

SM048

 

 

 

 

 

SM060

 

 

 

 

 

SM070

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Type (Qty 1)

 

Scroll

 

Scroll

 

Scroll

 

Scroll

 

Scroll

Refrigeration Charge VT/HZ

Oz.

 

58/58

 

 

 

 

 

98/85

 

 

 

 

 

88/77

 

 

 

 

 

110/100

 

 

 

 

 

114/114

Max Water Working Pressure

PSIG/kPa

 

450/3100

 

 

 

 

 

450/3100

 

 

 

 

 

450/3100

 

 

 

 

 

450/3100

 

 

 

 

 

450/3100

Constant Torque High Efficiency Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Type/Speeds

 

 

 

Const Torque

 

 

Const Torque

 

 

Const Torque

 

 

Const Torque

 

 

Const Torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor / 5 speed

 

 

Motor / 5 speed

 

 

Motor / 5 speed

 

 

Motor / 5 speed

 

 

Motor / 5 speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

 

HP

 

 

0.33

 

 

 

 

 

0.75

 

 

 

 

 

0.75

 

 

 

 

 

1.00

 

 

 

 

 

1.00

Blower Wheel Size

 

Inch

 

 

10 X 8

 

 

11 X 9

 

 

11 X 9

 

 

11 X 11

 

 

11 X 11

 

(Dia. x W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable Speed Constant CFM High Efficiency Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Type/Speeds

 

 

 

 

 

Variable Speed

 

 

Variable Speed

 

 

Variable Speed

 

 

Variable Speed

 

 

Variable Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Const CFM

 

 

 

Const CFM

 

 

 

Const CFM

 

 

 

Const CFM

 

 

 

Const CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

 

HP

 

0.33

 

 

 

 

0.75

 

 

 

 

0.75

 

 

 

 

1.00

 

 

 

 

1.00

Blower Wheel Size

 

 

Inch

 

 

10 X 8

 

 

 

11 X 9

 

 

 

11 X 9

 

 

 

11 X 11

 

 

 

11 X 11

 

(Dia. x W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Connection Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FPT Swivel Connection

 

Inch

 

1.0

 

 

 

 

1.0

 

 

 

 

1.0

 

 

 

 

1.0

 

 

 

 

1.0

Coaxial Coil Volume

 

Gal

 

0.33

 

 

 

 

1.18

 

 

 

 

0.62

 

 

 

 

1.07

 

 

 

 

1.12

Condensate Connection

 

Inch FPT

 

¾

 

 

 

 

¾

 

 

 

 

¾

 

 

 

 

¾

 

 

 

 

¾

Vertical Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil Dimensions (H x W)

 

 

 

 

Inch

 

 

24 X 20

 

 

 

 

32 X 26

 

 

 

 

32 X 26

 

 

 

 

38 X 26

 

 

 

 

38 x 26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(H x W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal size of Standard Filter - 2"

 

Inch

 

 

24 X 24 (1)

 

 

 

 

16 X 30 (2)

 

 

 

 

16 X 30 (2)

 

 

 

 

20 X 30 (2)

 

 

 

 

20 X 30 (2)

MERV13

 

 

 

 

(L x H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight - Operating

 

lbs

 

250

 

 

 

 

360

 

 

 

 

340

 

 

 

 

410

 

 

 

 

440

Weight - Shipping

 

lbs

 

350

 

 

 

 

475

 

 

 

 

450

 

 

 

 

530

 

 

 

 

560

Horizontal Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil Dimensions

 

 

 

 

 

Inch

 

 

18 X 31.5

 

 

 

 

 

20 X 42

 

 

 

 

 

20 X 42

 

 

 

 

 

20 X 49

 

 

 

 

 

20 X 49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(H x W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal size of Standard Filter - 2"

 

Inch

 

 

18 X 18 (2)

 

 

 

 

 

20 X 24 (2)

 

 

 

 

 

20 X 24 (2)

 

 

 

 

 

18 X 20 (3)

 

 

 

 

 

18 X 20 (3)

MERV13

 

 

 

 

 

(L x H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight - Operating (lbs)

 

lbs

 

260

 

 

 

 

375

 

 

 

 

355

 

 

 

 

430

 

 

 

 

460

Weight - Shipping (lbs)

 

lbs

 

360

 

 

 

 

495

 

 

 

 

470

 

 

 

 

550

 

 

 

 

580

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Thermotechnology Corp.

4 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

FullASHRAE/AHRI/ISOLoad - ASHRAE/AHRI/ISO13256-1. English13256-1(I.-P)EnglishUnits (I-P) Units

 

 

Water Loop Heat Pump

 

Ground Water Heat Pump

 

 

Ground Loop Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling 86 deg.F

Heating 68 deg.F

Cooling 59 deg.F

Heating 50 deg.F

Cooling

Heating

Models

Cooling 77 deg.F

Heating 32 deg.F

Cooling

 

86 deg.F

Heating

 

68 deg.F

Cooling

 

59 deg.F

Heating

 

50 deg.F

Full Load 77 °F

Full Load 32 °F

Models Load

 

 

 

 

Capacity

 

 

EER

Capacity

 

 

 

Capacity

 

 

EER

Capacity

 

 

 

Cap city

 

EER

Cap city

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Load 68 °F

Part Load 68 °F

 

Btuh

 

 

Btuh/W

Btuh

 

 

COP

Btuh

 

 

Btuh/W

Btuh

 

 

COP

Btuh

 

Btuh/W

Btuh

 

COP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

EER

Capacity

 

 

COP

Capacity

 

 

EER

Capacity

 

 

COP

Capacity

 

EER

Capacity

 

COP

SM024

25500Btuh

 

 

Btuh/W17.4

29200Btuh

 

 

29000Btuh

 

 

Btuh/W26.5

23500Btuh

 

 

26600Btuh

 

Btuh/W19.9

18000Btuh

 

 

 

 

 

5.6

 

 

 

 

4.9

 

 

4.1

SM036Full

39625500

 

 

197..34

42829200

 

 

5..6

4429000

 

 

286..35

35923500

 

 

54..19

41426600

 

2219..39

2184000

 

4..31

SM024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM048Partial

49218500

 

 

186..69

56121200

 

 

56..35

55321700

 

 

2533..36

4167003

 

 

45..71

5210003

 

1928..31

36914400

 

4..04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM060Full

63839000

 

 

179..0

73342800

 

 

5..26

70243300

 

 

248..40

60335900

 

 

45..61

65140800

 

1822..90

4280400

 

34..93

SM036

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM070Partial

71629000

 

 

1622..32

8431000

 

 

56..15

78732600

 

 

2337..10

70025200

 

 

45..52

73731900

 

1832..50

55322400

 

34..87

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full

49200

 

 

16.6

56100

 

 

5.3

55300

 

 

25.3

46300

 

 

4.7

51300

 

19.3

36900

 

4.0

SM048

36700

 

 

18.9

40900

 

 

6.2

42000

 

 

33.8

33700

 

 

5.2

39900

 

27.8

29800

 

4.5

Partial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full

63800

 

 

17.0

73300

 

 

5.2

70200

 

 

24.4

60300

 

 

4.6

65100

 

18.9

48000

 

3.9

SM060

47500

 

 

18.7

53600

 

 

5.8

53300

 

 

31.2

44300

 

 

4.8

51600

 

26.5

39800

 

4.4

Partial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full

71600

 

 

16.3

84000

 

 

5.1

78700

 

 

23.1

70000

 

 

4.5

73700

 

18.5

55300

 

3.8

SM070

55200

 

 

17.8

64900

 

 

5.7

60800

 

 

28.5

52900

 

 

4.8

60300

 

25.4

46900

 

4.3

Partial

 

 

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

Compressor

 

Total Unit Constant Torque High

Total Unit Variable Speed Constant

 

Voltage

Voltage/Phase/

Voltage

 

 

 

Efficiency Motor

CFM High Efficiency Motor

Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Hz

Min/Max

QTY

RLA

 

LRA

FLA

 

Min Circuit

Max Fuse/

FLA

Min Circuit

Max Fuse/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

HACR

Amps

HACR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM024

1

208-230/1/60

197/253

1

11.7

 

58.3

2.8

 

17.4

25

2.8

17.4

25

SM036

1

208-230/1/60

197/253

1

15.3

 

83.0

6.0

 

25.1

40

6.8

25.9

40

SM048

1

208-230/1/60

197/253

1

21.2

 

104.0

6.0

 

32.4

50

6.8

33.2

50

SM060

1

208-230/1/60

197/253

1

27.1

 

152.9

7.6

 

41.5

60

9.1

43.0

70

SM070

1

208-230/1/60

197/253

1

29.7

 

179.2

7.6

 

44.7

70

9.1

46.2

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units with Factory Installed Electric Heat option will have two separate data plates for each

electrical circuit.

1st Data plate for units with EH option - compressor power connection

 

 

Voltage/Phase/

Voltage Min/

 

 

Compressor

 

 

Models

Voltage Code

 

 

 

 

 

Hz

Max

QTY

RLA

LRA

Min Circuit

Max Fuse/

 

 

 

 

 

 

 

 

 

 

Amps

HACR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM024

1

208-230/1/60

197/253

1

11.7

58.3

14.6

25

SM036

1

208-230/1/60

197/253

1

15.3

83.0

19.1

30

SM048

1

208-230/1/60

197/253

1

21.2

104.0

26.5

45

SM060

1

208-230/1/60

197/253

1

27.1

152.9

33.9

60

SM070

1

208-230/1/60

197/253

1

29.7

179.2

37.1

60

 

 

 

 

 

 

 

 

 

 

 

Bosch Thermotechnology Corp.

5 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

2nd data plate for units with EH option - Constant Torque ECM motor

 

Electric

 

Heater

Heater

 

Circuit

 

MCA

 

MOCP

 

 

Watts

 

Amps

Motor

 

 

 

 

 

 

 

 

 

 

 

 

Model

Heater Rated

Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLA (A)

 

 

 

 

 

 

 

 

kW

 

240V

208V

240V

 

208V

Fuses

240V

 

208V

240V

 

208V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM024

4.8

1

4,800

3,600

20.0

 

17.3

2.8

-

28.5

 

25.1

30

 

30

SM036

4.8

1

4,800

3,600

20.0

 

17.3

6.0

-

32.5

 

29.1

35

 

30

SM036

9.6

1

9,600

7,200

40.0

 

34.6

6.0

-

57.5

 

50.8

60

 

60

SM048

4.8

1

4,800

3,600

20.0

 

17.3

6.0

-

32.5

 

29.1

35

 

30

SM048

9.6

1

9,600

7,200

40.0

 

34.6

6.0

-

57.5

 

50.8

60

 

60

SM048

14.4

2

14,400

10,800

60

 

51.9

6

F1/F2

82.5

 

72.4

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM060

4.8

1

4,800

3,600

20.0

 

17.3

7.6

-

34.5

 

31.1

35

 

35

SM060

9.6

1

9,600

7,200

40.0

 

34.6

7.6

-

59.5

 

52.8

60

 

60

SM060

14.4

2

14,400

10,800

60

 

51.9

7.6

F1/F2

84.5

 

74.4

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM060

19.2

2

19,200

14,000

80

 

69.2

7.6

F1/F2

109.5

 

96.0

110

 

100

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM070

4.8

1

4,800

3,600

20.0

 

17.3

7.6

-

34.5

 

31.1

35

 

35

SM070

9.6

1

9,600

7,200

40.0

 

34.6

7.6

-

59.5

 

52.8

60

 

60

SM070

14.4

2

14,400

10,800

60

 

51.9

7.6

F1/F2

84.5

 

74.4

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM070

19.2

2

19,200

14,000

80

 

69.2

7.6

F1/F2

109.5

 

96.0

110

 

100

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Thermotechnology Corp.

6 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

2nd data plate for units with EH option - Constant Airflow ECM motor

 

Electric

 

Heater

Heater

 

Circuit

 

MCA

 

MOCP

 

 

Watts

 

Amps

Motor

 

 

 

 

 

 

 

 

 

 

 

 

Model

Heater Rated

Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLA (A)

 

 

 

 

 

 

 

 

kW

 

240V

208V

240V

 

208V

Fuses

240V

 

208V

240V

 

208V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM024

4.8

1

4,800

3,600

20.0

 

17.3

2.8

-

28.5

 

25.1

30

 

30

SM036

4.8

1

4,800

3,600

20.0

 

17.3

6.8

-

33.5

 

30.1

35

 

35

SM036

9.6

1

9,600

7,200

40.0

 

34.6

6.8

-

58.5

 

51.8

60

 

60

SM048

4.8

1

4,800

3,600

20.0

 

17.3

6.8

-

33.5

 

30.1

35

 

35

SM048

9.6

1

9,600

7,200

40.0

 

34.6

6.8

-

58.5

 

51.8

60

 

60

SM048

14.4

2

14,400

10,800

60

 

51.9

6.8

F1/F2

83.5

 

73.4

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM060

4.8

1

4,800

3,600

20.0

 

17.3

9.1

-

36.4

 

33.0

40

 

35

SM060

9.6

1

9,600

7,200

40.0

 

34.6

9.1

-

61.4

 

54.6

70

 

60

SM060

14.4

2

14,400

10,800

60

 

51.9

9.1

F1/F2

86.4

 

76.3

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM060

19.2

2

19,200

14,000

80

 

69.2

9.1

F1/F2

111.4

 

97.9

125

 

100

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM070

4.8

1

4,800

3,600

20.0

 

17.3

9.1

-

36.4

 

33.0

40

 

35

SM070

9.6

1

9,600

7,200

40.0

 

34.6

9.1

-

61.4

 

54.6

70

 

60

SM070

14.4

2

14,400

10,800

60

 

51.9

9.1

F1/F2

86.4

 

76.3

90

 

80

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM070

19.2

2

19,200

14,000

80

 

69.2

9.1

F1/F2

111.4

 

97.9

125

 

100

 

 

 

 

 

F3/F4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Thermotechnology Corp.

7 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

Unit Supply Air Configurations

Top Discharge (Default)

Back Discharge

Side Discharge

 

 

 

 

 

 

Unit Return Air Configurations

 

 

 

 

 

Left Air Return

Right Air Return

Electrical Box can be relocated inside unit.

 

 

Bosch Thermotechnology Corp.

8 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

SM-VT Dimensions and Connections

 

 

 

kit

kit

Conversion Kit

Application

SM024VT Config kit

SM036/048VT Config

SM060/070VT Config

Configuration

Part #

8-733-938-189

8-733-938-190

8-733-938-191

 

 

Bosch Thermotechnology Corp.

9 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

SM-HZ End Blow Dimensions and Connections

 

 

Bosch Thermotechnology Corp.

10 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

SM-HZ Straight Through Dimensions and Connections

 

 

Bosch Thermotechnology Corp.

11 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

SM-HZ Hanging Bracket Dimensions and Connections

 

 

Bosch Thermotechnology Corp.

12 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

SM Series

Residential Geothermal Heat Pumps

SM-CF Dimensions and Connections

 

 

Bosch Thermotechnology Corp.

13 of 42

 

Londonderry, NH

• Ft. Lauderdale, FL

 

 

 

 

 

 

Bosch Thermotechnology Corp. reserves the right to make changes without notice due

Tel: 1-866-642-3198 Fax: 1-954-776-5529

www.bosch-climate.us

to continuing engineering and technological advances |

BTC 760108301 G | 10.2015

 

 

Loading...
+ 29 hidden pages