The Blue Line Gen2 TriTech Motion Detectors (ISCBDL2) use a combination of passive infrared (PIR) and microwave detection technologies with advanced signal processing. The pet friendly ( WP) models generate alarms for human intruders without generating false alarms for pets. These small unobtrusive detectors are simple to install and do not need field adjustments.

Functions

First Step Processing (FSP)

First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing. This eliminates the need for the installer to select the sensitivity level, thus improving ease of installation and reliability.

Pet friendly Selectivity ( WP models only)

The installer can turn pet immunity on or off based upon application requirements. When pet immunity is turned off, the detector provides superior catch performance identical to the non pet models. When pet immunity is turned on, the detector can

uPet friendly Selectable model available – optimize installation for pet (45 kg [100 lb]) and non pet applications

uDynamic Temperature Compensation – superior catch performance in any environment

uMicrowave Noise Adaptive processing – reduce false alarms from repetitive sources

uWall to Wall Coverage – superior catch performance

uFlexible Mounting Height, No Adjustments – reduce installation time and false alarms, improve catch performance

distinguish between signals caused by humans and signals caused by pets. It ignores signals caused by one or two pets up to 45 kg (100 lb) or numerous rodents.

Microwave Noise Adaptive Processing

Microwave Noise Adaptive Processing adjusts to background disturbances, reducing false alarms without sacrificing intruder detection.

Dynamic Temperature Compensation

The detector intelligently adjusts its sensitivity so that it can identify human intruders at virtually any temperature.

Wall-to-Wall Coverage

An improved lookdown zone and coverage range of 12 m x 12 m (40 ft x 40 ft) provide wall-to-wall coverage.

Self-locking Enclosure

The sliding self locking enclosure has an integrated bubble level and custom gap free, lift gate style terminal blocks to make installation easier.

2 | Blue Line Gen2 TriTech Motion Detectors

Sealed Optics and Electronics

The optics and electronics are assembled into the front enclosure and sealed with a protective cover to prevent damage during installation. The sealed optical chamber also prevents drafts and insects from affecting the detector.

Test Features

Externally visible alarm LED can be disabled after installation.

Certifications and approvals

These detectors are also designed to comply with the following:

Europe

Complies with EN50131-2-4 Grade 2

 

Complies with EN50130-5 Class II

 

Complies with EN60529, EN50102 (IP30, IK04)

 

Complies with Directive 2002/95/EC - Restriction of the

 

use of certain Hazardous Substances (RoHS)

China

Complies with CCC GB10408.1 and GB10408.9

 

 

Region

Certification

 

 

 

 

 

GODKJENNELSESBEVIS [-WP6, -W12, -

 

 

WP12]

Europe

CE

2004/108/EC: EMC Directive,

 

 

2006/95/EC: Low-Voltage Directive,

 

 

and 1999/5/EC Radio Equipment and

 

 

Telecommunications Terminal Equip-

 

 

ment (R&TTE), 2011/65/EU: Restriction

 

 

of the use of certain hazardous substan-

 

 

ces in electrical and electronic equip-

 

 

ment [-WP6G, WP12G, and W12G]

 

CE

2004/108/EC: EMC Directive,

 

 

2006/95/EC: Low-Voltage Directive,

 

 

and 1999/5/EC Radio Equipment and

 

 

Telecommunications Terminal Equip-

 

 

ment (R&TTE), 2011/65/EU: Restriction

 

 

of the use of certain hazardous substan-

 

 

ces in electrical and electronic equip-

 

 

ment [-WP12H, -W12H]

 

EN5013

EN50131-2-4 [-WP12G]

 

1

 

 

EN5013

EN50131-2-4 [-W12G]

 

1

 

 

EN5013

EN50131-2-4 [-WP12H]

 

1

 

 

EN5013

EN50131-2-4 [-WP6G]

 

1

 

 

EN5013

EN50131-2-4 [-W12H]

 

1

 

Belgium

INCERT

B-509-0052/f [ISC-BDL2-W12G, -

 

 

WP12G, -WP6G]

 

INCERT

B-509-0052/f [ISC-PDL1-W18G, -

 

 

WC30G, -WA18x; ISC-BDL2-WP12G]

USA

UL

cULus - ANSR: Intrusion-detection Units

 

 

(UL 639), ANSR7: Intrusion-detection

 

 

Units Certified for Canada (ULC-S306)

 

 

[-W12G, -WP12G, -WP6G]

 

 

 

Region

Certification

 

 

 

 

FCC

T3X-BLG2 [-W12G, -WP12G, -WP6G]

Canada

IC

1249A-BLG2 [-W12G, -WP12G, -

 

 

WP6G]

France

AFNOR

2820200003D0 [-WP12G]

 

AFNOR

2820200003C0 [-W12G]

 

AFNOR

2820200003B0 [-WP12H]

 

AFNOR

2820200003E0 [-WP6G]

 

AFNOR

2820200003A0 [-W12H]

China

CCC

2010031901000323 [-CHI]

Sweden

INTYG

11-266 [-W12G]

 

INTYG

11-264 [-WP6G]

 

INTYG

11-265 [-WP12G]

Brazil

ANATEL

2140-10-1855 [-W12G, -WP12G, -

 

 

WP6G]

the Nether-

NCP

2011062 [ISC-BPR2-w12, -WP12, ISC-

lands

 

BPQ2-W12, ISC-BDL2-W12G, ISC-

 

 

BDL2-WP12G, ISC-BDL2-WP6G]]

 

 

 