Panasonic WV-CP230 User Manual

5 (1)
Panasonic WV-CP230 User Manual

Colour CCTV Cameras

WV-CP230/WV-CP232/WV-CP234

Before attempting to connect or operate this product, please read these instructions completely.

N1098-0

YWV8QA5084AN Printed in Japan

 

N 30

 

 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead symbol, within an equilateral triangle, is interned to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC/73/23 and EEC/89/336.

Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto a cui si riferisce la presente dichiarazione risulta conforme ai seguenti standard o altri documenti normativi conformi alle disposizioni delle direttive CEE/73/23 e CEE/89/336.

Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatiefve dokumenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC.

Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration omhandler, er i overensstemmelse med den følgende standarder eller andre normative dokumenter i følge bestemmelserne i direktivene 73/23/EEC og 89/336/EEC.

Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna deklaration hänvisar är i överensstämmelse med standarddokument, eller andra normativa dokument som framstölls i Direktiv 73/23/EEC och 89/336/EEC.

Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä ilmoitus koskee, noudattaa seuraavia standardeja tai muita ohjeellisia asiakirjoja, jotka noudattavat direktiivien 73/23/EEC ia 89/336/EEC. säädöksiä.

Vi erklærer oss alene ansvarlige for at produktet som denne erklæringen gjelder for, er i overensstemmelse med følgende normer eller andre normgivende dokumenter som fælger bestemmelsene i direktiven 73/23/EEC og 89/336/EEC.

For U.K.

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This appliance is supplied with a moulded three pin mains plug for your safety and convenience.

A 5 amp fuse is fitted in this plug.

Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5 amp and that it is approved by ASTA or BSI to BS1362.

Check for the ASTA mark Hor the BSI mark Gon the body of the fuse.

If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced.

If you lose the fuse cover the plug must not be used until a replacement cover is obtained.

A replacement fuse cover can be purchased from your local Panasonic Dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY.

THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.

If a new plug is to be fitted please observe the wiring code as shown below.

If in any doubt please consult a qualified electrician.

WARNING:

This apparatus must be earthed.

IMPORTANT

The wires in this mains lead are coloured in accordance with the following code.

Green-and-yellow:

Earth

Blue:

Neutral

Brown:

Live

As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol Ior coloured green or green-and-yellow.

The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L or coloured red.

How to replace the fuse

Open the fuse compartment with a screwdriver and replace the fuse and fuse cover.

The serial number of this product may be found on the top of the unit.

You should note the serial number of this unit in the space provided and retain this instruction as a permanent record of your purchase to aid identification in the event of theft.

Model No.

Serial No.

WARNING:

TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

FEATURES

1. The following functions are built in.

2.

Minimum illumination of 0.6 lx (0.06 foot-can-

(1)

Auto Light Control (ALC)/Electronic Light

 

dle) at F0.75 (equivalent to 2.0 lx (0.2 foot-

 

Control (ELC)

 

candle) at F1.4)

(2)

Automatic Gain Control (AGC) +15 dB

 

 

 

and Automatic Tracing White Balance

3.

Signal-to-noise ratio of 50 dB

 

(ATW)

 

 

(3)

Camera synchronization mode selec-

4.

Horizontal resolution of 480 lines

 

table between internal (INT), Line-locked

 

 

 

(LL) and Multiplexed Vertical Drive (VD2)

5.

Auto iris lens control selectable between

 

for WV-CP230 and WV-CP234.

 

video signal and DC power supply.

PRECAUTIONS

1.Do not attempt to disassemble the camera.

To prevent electric shock, do not remove screws or covers.

There are no user serviceable parts inside. Ask a qualified service person for servicing.

2.Handle the camera with care.

Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.

3.Do not expose the camera to rain or moisture, or try to operate it in wet areas.

Turn the power off immediately and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock.

4.Do not use strong or abrasive detergents when cleaning the camera body.

Use a dry cloth to clean the camera when dirty.

In case the dirt is hard to remove, use a mild detergent and wipe gently.

5.Clean the CCD faceplate with care.

Do not clean the CCD with strong or abrasive detergents. Use lens tissue or a cotton tipped applicator and ethanol.

6.Never face the camera towards the sun.

Do not aim the camera at bright objects. Whether the camera is in use or not, never aim it at the sun or other extremely bright objects. Otherwise, blooming or smear may be caused.

7.Do not operate the camera beyond the specified temperature, humidity or power source ratings.

Use the camera under conditions where temperature is between –10°C - +50°C (14°F - 122°F), and humidity is below 90 %. The input power source is 220 - 240 V AC 50 Hz for WV-CP230, 12 V DC for WV-CP232, and 24 V AC 50 Hz for WV-CP234.

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

<WV-CP230>

 

 

LL

INT

WV–CP230

 

ELC

ALC

 

 

SOFT

SHARP

 

 

OFF

BLC ON

 

 

DC

VIDEO

 

VIDEO OUT

 

 

 

<WV-CP234>

 

AC 24V IN

GND

 

 

 

 

 

 

LL

INT

 

 

ELC

ALC

 

 

SOFT

SHARP

 

1 2

OFF

BLC ON

 

DC

VIDEO

 

VIDEO OUT

<WV-CP232>

DC 12V IN

ELC ALC SOFT SHARP 0FF BLC ON DC VIDEO

VIDEO OUT

qAuto Iris Lens Connector

Supplies power and control signals to an auto iris lens (not supplied).

wFlange-back Adjusting Ring

This ring adjusts the back-focal distance or picture focus. Rotate this ring clockwise for a C-mount lens or counterclockwise for a CSmount lens.

e Lens (option)

rCamera Mounting Screw Hole

This hole is for mounting the camera onto a mounting bracket. The camera is originally designed to be mounted from the bottom, but a top-mounting type is also available. To mount from the top, remove the mount adapter from the bottom of the camera by removing two fixing screws. Attach the mount adapter to the top as shown in the diagram, then mount the camera on the mounting bracket. Make sure that two original screws are used when mounting the mount adapter; longer type screws may damage inner components.

tPower Cord (only WV-CP230)

Connect this power cord to an electrical outlet of 220 - 240 V AC 50 Hz.

yDC 12 V Input Terminal

(DC 12 V IN (only WV-CP232))

This terminal is for connecting the 12 V DC power supply cord.

uAC 24 V Input Terminal

(AC 24 V IN (only WV-CP234))

This terminal is for connecting the 24 V AC 50 Hz power supply cord.

iSynchronization Mode Selector

(INT, LL (only WV-CP230 and WV-CP234))

Selects the camera synchronization mode from internal sync mode (INT) or line-lock mode (LL).

INT: Sets to internal 2:1 interlace. LL: Sets to Line-lock mode.

oAutomatic Light Control/Electronic Light Control Selector (ALC , ELC)

Lets you select the mode according to the lens type that is used with this camera.

ALC: Select this mode when an auto iris lens (ALC lens) is used with this camera.

ELC: Select this mode when a fixed iris lens or manual iris lens is used with this camera.

!0Detail/Aperture Level Selector

(SOFT/SHARP)

The detail/aperture level can be selected with this selector. Set it to the desired position while observing the picture on the monitor.

SHARP: Normal position.

SOFT: Select this position when a Quad System is connected to this camera.

!1Back Light Compensation Mode Selector

(BLC ON, OFF)

Lets you select the mode according to the position of the object and light conditions on the screen.

ON: Select this mode when a strong light such as a spotlight is in the background.

OFF: Normal picture.

!2Lens Drive Signal Selector (VIDEO, DC)

Lets you select the mode according to the type of auto iris lens drive signal to be supplied to the lens from the auto iris lens connector.

VIDEO: Select this mode if you are using a auto iris lens that requires a video drive signal.

DC: Select this mode if you are using a auto iris lens that requires a DC drive signal.

!3Video Output Connector (VIDEO OUT)

This connector is for connecting with the VIDEO IN connector of the video monitor. Whenever the multiplexed vertical drive (VD2) signal is supplied to this connector, the camera synchronization mode is automatically set to Vertical Drive.

Caution:

Connect to 12 V DC (10.5 V-16 V) or 24 V AC (19.5 V-28 V) class 2 power supply only. Make sure to connect the grounding lead to the GND terminal when the power is supplied from a 24 V AC power source.

CONNECTIONS

A. WV-CP230 (220 - 240 V AC 50 Hz)

Connect the power cord to an electrical outlet of 220 - 240 V AC 50 Hz.

B. WV-CP232 (12 V DC)

Connect the power cord to the DC 12 V IN terminal on the rear panel of the WV-CP232.

@!

12 V DC

(10.5 V - 16 V)

Resistance of copper wire [at 20°C (68°F)]

Copper wire

#24

#22

#20

#18

size (AWG)

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

Resistance

0.078

0.050

0.030

0.018

Ω/m

 

 

 

 

Resistance

0.026

0.017

0.010

0.006

Ω/ft

 

 

 

 

Calculation of maximum cable length between camera and power supply :

10.5 V DC ≤ VA − (R x 0.42 x L) ≤ 16 V DC

L : Cable length (meters)

R : Resistance of copper wire (Ω/meter)

VA : DC output voltage of power supply unit

 

 

VA − 12

L standard =

 

 

(meters)

 

 

 

 

0.42 x R

 

 

VA − 16

L minimum =

 

 

(meters)

 

 

 

 

0.42 x R

 

VA − 10.5

L maximum =

 

 

(meters)

 

 

0.42x R

C.WV-CP234 (24 V AC 50 Hz)

Connect the power cable to the AC 24 V IN terminal on the rear panel of the WV-CP234.

1 2

24 V AC, 50 Hz

(19.5 V - 28 V)

Recommended wire gauge sizes for 24 V AC line

Copper wire

#24

#22

#20

#18

size (AWG)

 

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

Length

 

(m)

95

150

255

425

of Cable

 

 

 

 

 

 

 

 

 

 

 

 

(Approx.)

 

(ft)

314

495

842

1 403

 

 

 

 

 

 

 

Installation of Auto Iris Lens

Connector

Install the lens connector (YFE4191J100) when using a video drive ALC lens.

The installation should be made by qualified service personnel or system installers.

Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover of the supplied connector as shown in the diagram.

The pin assignment of the lens connector is as follows:

Pin 1: Power source; +9 V DC, 50 mA max. Pin 2: Not used

Pin 3: Video signal; 1.3 V[p-p]/40 kΩ Pin 4: Shield, ground

Rib

Pin 3

Pin 1

Pin 4

Pin 2

Solder the lens cable to the pins of the supplied connector.

Mounting the Lens

Caution:

Before you mount the lens, loosen the two screws on the ring, and rotate this ring clockwise until it stops. If the ring is not at the end, the inner glass or CCD image sensor may be damaged.

qMount the lens by turning it clockwise on the lens mount of the camera.

wConnect the lens cable to the auto iris lens connector on the side of the camera.

Screws

q

w

Flange-back

Adjusting Ring

Caution for Mounting the Lens

The lens mount should be a C-mount or CS-mount (1”-32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the lens and camera should be secured by using the supporter.

The protrusion at the rear of the lens should be as shown in the diagram.

C-mount: Less than 13 mm (1/2”)

CS-mount: Less than 8 mm (5/16”)

FOCUS OR FLANGE-BACK ADJUSTMENT

The following adjustment should be made by qualified service personnel or system installers.

qLoosen the screws on the flange-back adjusting ring.

 

w

 

Flange-back

qe

Adjusting Ring

Screws

 

wTurn the flange-back adjusting ring to the desired position.

Caution: When the C-mount lens is mounted, do not rotate the ring counterclockwise by force after it stops. If the ring is rotated by force, the inner lens or CCD image sensor may be damaged.

eTighten the screws on the flange-back adjusting ring.

SPECIFICATIONS

Pick-up Device:

752 (H) x 582 (V) pixels, Interline Transfer CCD

Scanning Area:

4.89 (H) x 3.67 (V) mm (Equivalent to scanning area of 1/3”

 

pick-up tube)

 

Synchronization:

Internal, Line-locked or Multiplexed vertical drive (VD2)

 

selectable

 

Scanning System:

2 : 1 interlace

 

Scanning:

625 lines / 50 fields / 25 frames

Horizontal:

15.625 kHz

 

Vertical:

50 Hz

 

Horizontal Resolution:

480 lines

 

Video Output:

1.0 V[p-p] PAL composite 75 Ω / BNC connector

Signal-to-Noise Ratio:

50 dB (AGC OFF, weight ON)

Electronic Light Control:

Equivalent to continuous variable shutter speed between 1/50 s

 

and 1/15 000 s

 

Minimum Illumination:

0.6 lx (0.06 foot-candle) at F0.75 [equivalent to 2.0 lx (0.2 foot-

 

candle) at F1.4] AGC ON

Detail:

SHARP or SOFT, selectable

Lens Mount:

C-mount or CS-mount, selectable

Ambient Operating Temperature:

−10°C - +50°C (14°F - 122°F)

Ambient Operating Humidity:

Less than 90 %

 

Power Source and

WV-CP230:

220 - 240 V AC 50 Hz, 3.9 W

Power Consumption:

WV-CP232:

12 V DC, 270 mA

 

WV-CP234:

24 V AC 50 Hz, 3.7 W

Dimensions (without lens):

67 (W) x 65 (H) x 123 (D) mm

 

[2-5/8” (W) x 2-9/16” (H) x 4-13/16” (D)]

Weights (without lens):

WV-CP230:

0.62 kg (1.37 lbs)

 

WV-CP232:

0.4 kg (0.88 lbs)

 

WV-CP234:

0.43 kg (0.95 lbs)

Weights and dimensions indicated are approximate.

Specifications are subject to change without notice.

STANDARD ACCESSORIES

Body Cap............................................................................................

1 pc.

ALC Lens Connector (YFE4191J100).................................................

1 pc.

OPTIONAL ACCESSORIES

Lenses: WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LA210C3, WV-LA408C3, WV-LA908C3, WV-LZ61/10, WV-LZ62/2, WV-LZ62/8, WV-LF4R5C3A, WV-LF9C3A, WV-LFY3C3, WV-LFY45C3, WV-LFY9C3

Matsushita Electric Industrial Co., Ltd.

Central P.O. Box 288, Osaka 530-91, Japan

Loading...
+ 2 hidden pages