ENGLISH |
2 ~ 11 |
|||
Before operating the unit, read these operating |
||||
instructions thoroughly and keep them for future |
||||
reference. |
|
|||
ESPAÑOL |
12 ~ 21 |
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
ITALIANO |
22 ~ 31 |
Prima di utilizzare l’unità si prega di leggere |
|
attentamente le istruzioni e di conservare questo |
|
opuscolo per potervi fare riferimento in futuro. |
|
DEUTSCH |
32 ~ 41 |
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
PORTUGUÊS |
42 ~ 51 |
Antes de ligar a unidade, leia cuidadosamente |
|
este manual de utilização e guarde-o para futura |
|
referência. |
|
NEDERLANDS |
52 ~ 61 |
Lees voor u het apparaat gebruikt deze |
|
gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik.
QUICK GUIDE / GUÍA RÁPIDA
GUIDA RAPIDA / KURZANLEITUNG
GUΙA RÁPIDO / SNELLE GIDS
F566077
Operating Instructions
Air Conditioner
Indoor Unit CS-F14DB4E5 CS-F18DB4E5 CS-F24DB4E5 CS-F28DB4E5
Outdoor Unit
Inverter Model (HBE5 Series)
CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
(GBE5 Series)
CU-YL24GBE5 CU-YL28GBE5 CU-YL34GBE5 CU-YL43GBE5
Heat-pump Model
CU-B14DBE5 CU-B18DBE5 CU-B24DBE5 CU-B28DBE5 CU-B34DBE5
Cooling Model
CU-J14DBE5 CU-J18DBE5 CU-J24DBE5 CU-J28DBE5 CU-J34DBE5
CS-F34DB4E5 CS-F43DB4E5 CS-F50DB4E5
(DBE5, DBE8 Series)
CU-L24DBE5
CU-L28DBE5
CU-L34DBE5
CU-L43DBE5
CU-L34DBE8
CU-L43DBE8
CU-L50DBE8
CU-B28DBE8
CU-B34DBE8
CU-B43DBE8
CU-B50DBE8
CU-J24DBE8
CU-J28DBE8
CU-J34DBE8
CU-J43DBE8
CU-J50DBE8
© 2008 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.
SAFETY PRECAUTIONS |
|
DEFINITION |
|
The instructions to be followed are classified by the following symbols: |
|
This symbol denotes an action |
These symbols denote actions |
that is PROHIBITED. |
that are COMPULSORY. |
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classified as below:
Warning This sign warns of death or serious injury. |
|
This sign warns of |
|
Caution |
injury or damage |
||
|
|
|
to property. |
Wireless Remote Control |
Indoor Unit |
Indoor Unit |
•Do not use rechargeable (Ni-Cd) batteries.
•Do not allow infants and small children to play with the remote control to prevent them from
accidentally swallowing the batteries.
•Remove the batteries if the unit is not going to be used for a long period of time.
•New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
Power Supply
•Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.
•Do not insert your fingers or other objects into the unit.
•Do not attempt to repair the unit by yourself.
Air outlet Air inlet
•Do not share the same power outlet with other equipment.
•Do not modify power cords.
•Do not use extension cords.
•Do not operate with wet hands.
•Use the specified supply cord.
•If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
•This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fire in case of malfunction.
•In case of emergency or abnormal
conditions (burnt smell, etc), turn off the power supply, and consult your nearest dealer.
Outdoor Unit
•Do not insert your fingers or other objects into the unit, sharp parts may cause
2 |
injury. |
|
Air inlet
Air inlet
Air outlet
•Do not install the unit in a potentially explosive atmosphere.
•Do not wash the unit with water, benzene, thinner or scouring powder.
•Do not use for other purposes such as preservation of food.
•Do not use any combustible equipment in front of the airflow outlet.
•Do not expose directly to cold air for a long period.
•Ensure that the drainage pipe is connected properly. Otherwise,
leakage may occur.
• Aerate the room regularly.
Power Supply
• Switch off the power supply before cleaning or servicing.
• Turn off the power supply if the unit is not used for a long period of time.
•This air conditioner is equipped with a built-in surge protective device. However, in order
to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock.
Outdoor Unit
•Do not sit or step on the unit, you may fall down accidentally.
•Do not touch the sharp aluminum fin, sharp parts may cause injury.
•Ensure that the drainage pipe is connected properly. Otherwise,
leakage may occur.
•After long periods of use, make sure the installation rack is not damaged.
REGULATORY INFORMATION
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Thank you for purchasing Air Conditioner
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2
OPERATION CONDITION |
|
|
|
|
||
Use this air conditioner under the following temperature range |
|
|
||||
|
Model |
Temperature (°C) |
|
Indoor |
Outdoor |
|
|
|
|
|
|
|
|
|
Inverter |
COOLING |
Maximum |
|
32 |
43 |
|
Minimum |
|
21 |
-15* |
||
|
(GBE5, DBE5, |
|
|
|||
|
|
Maximum |
|
27 |
24 |
|
|
DBE8 Series) |
HEATING |
|
|||
|
Minimum |
|
16 |
-20 |
||
|
|
|
|
|||
|
|
COOLING |
Maximum |
|
32 |
43 |
|
Heat-pump |
Minimum |
|
21 |
-10** |
|
|
|
|
||||
|
HEATING |
Maximum |
|
27 |
24 |
|
|
|
|
||||
|
|
Minimum |
|
16 |
-10 |
|
|
|
|
|
|||
|
Cooling |
COOLING |
Maximum |
|
32 |
43 |
|
Minimum |
|
21 |
-10** |
||
|
|
|
|
NOTICE: This unit is still able to operate as a cooler with outdoor temperature as low as -15°C*/ -10°C** in a non-living room, such as a computer room, with a room temperature of 21°C or above, and room humidity up to 45%.
(CU-YL24HBE5, CU-YL28HBE5, CU-YL34HBE5, CU-YL43HBE5)
Temperature (°C) |
Indoor |
Outdoor |
||
|
|
|
|
|
COOLING |
Maximum |
32 |
43 |
|
Minimum |
21 |
-5 |
||
|
||||
HEATING |
Maximum |
27 |
24 |
|
Minimum |
16 |
-15 |
||
|
NOTICE: This unit is still able to operate as a cooler with outdoor temperature as low as -5°C in a non-living room, such as a computer room, with a room temperature of 21°C or above, and room humidity up to 45%.
REGULATORY INFORMATION
3
PRODUCT OVERVIEW & OPERATIONS
(WIRELESS REMOTE CONTROL)
4~5
PRODUCT OVERVIEW & OPERATIONS
(WIRED REMOTE CONTROL)
6~8
CARE & CLEANING
9
TROUBLESHOOTING
10~11
QUICK GUIDE
BACK COVER
NOTE :
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
Information for Users on Collection and Disposal of Old Equipment and used Batteries
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and
electronic products and batteries should not be mixed with general household waste.
For proper treatment, recovery and recycling of old products and used batteries, please take them to
applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and
2006/66/EC.
By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your
local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
Pb This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
•Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit.
•Do not install the unit in oily and smoky areas.
ENGLISH
3
PRODUCT OVERVIEW & OPERATIONS (WIRELESS REMOTE CONTROL)
Control Panel |
|
|
POWER |
|
Ray receiver |
|
||
TIMER |
|
|
FILTER
ECONOMY |
AUTO |
ODOUR WASH |
Airflow direction louver
Air filter
Intake grille
Air is discharged evenly
Auto OFF/ON button
•To operate the unit if the wireless remote control is misplaced or malfunctioning.
Action |
Mode |
|
Press once. |
Auto |
|
Press and hold until you hear 1 beep, |
Cooling |
|
then release. |
||
|
||
1.Press and hold until you hear 2 |
|
|
beeps then release. |
Heating |
|
2.Press the SET button for 5 seconds. |
|
|
Press the button to turn off. |
|
Remote control display
MODE
AIR SWING
FAN SPEED
Transmitter
Maximum distances: 8m
Remote Control Preparation
1Press and pull out
2Insert AAA or R03 batteries (can be used ~ 1 year)
3Press CLOCK
4Set time
5Confirm
6Close the cover
|
ECONOMY |
|
OFF/ON |
||
|
|
|
|
|
|
|
MODE |
ODOUR |
|
|
|
|
|
|
|
|
|
|
|
|
WASH |
|
|
|
AUTO |
|
MANUAL |
|
|
|
|
|
FAN |
4 |
|
|
|
|
|
||
3 |
SELECT |
|
|
SET |
|
CLOCK |
|
|
5 |
||
|
CANCEL |
||||
|
|
|
|||
|
S |
SET |
|
|
|
|
|
|
|
|
2 6
1
Inverter / Heat-pump Model
CZ-RL513B
Cooling Model
4 CZ-RL013B
OFF/ON
TO TURN ON OR OFF THE POWER
UNIT
TO SET TEMPERATURE
• Selection range: 16°C ~ 31°C.
MODE |
TO SELECT OPERATION MODE |
AUTO mode - For your convenience
•Unit selects operation mode according to temperature setting, outdoor and room temperature.
HEAT mode - To enjoy warm air
•Unit takes a while to warm up.
(Applicable for Inverter / Heat-pump Model)
FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
•Unit operates at low fan speed to give a gentle cooling operation.
•During soft dry operation, the indoor fan operates at a low fan speed.
•The louvers movement might not align with the remote control display.