HP BL860c i4, BL870c i4, BL890c i4 User Manual

0 (0)

HP Integrity BL860c i4, BL870c i4 & BL890c i4 Server Blade User Service Guide

Abstract

This document contains specific information that is intended for users of this HP product.

HP Part Number: 5900-2673

Published: August 2013

Edition: 3

© Copyright 2012, 2013 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Acknowledgments

Intel, Pentium, Itanium, Intel Inside, and the Intel Inside logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

Warranty

To get a copy of the warranty for this product see the warranty information website:

http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01865770/c01865770.pdf

Revision history

Document manufacturing

Operating systems

Supported product

Edition number

Publication Date

part number

supported

versions

 

 

5992-1083

HP-UX

BL860c i4, BL870c i4 &

First

December 2012

 

 

BL890c i4

 

 

5900-2663

HP-UX

BL860c i4, BL870c i4 &

Second

May 2013

 

 

BL890c i4

 

 

5900-2673

HP-UX

BL860c i4, BL870c i4 &

Third

August 2013

 

 

BL890c i4

 

 

Contents

 

1 Overview..................................................................................................

7

Server blade overview...............................................................................................................

7

Server blade components..........................................................................................................

8

2 Site preparation.........................................................................................

9

Server blade dimensions and weight...........................................................................................

9

Enclosure information................................................................................................................

9

Enclosure environmental specifications.........................................................................................

9

Sample Site Inspection Checklist...............................................................................................

10

Power subsystem.....................................................................................................................

12

ESD handling information........................................................................................................

12

Unpacking and inspecting the server blade................................................................................

12

Verifying site preparation....................................................................................................

13

Inspect the shipping containers for damage...........................................................................

13

Unpacking the server blade................................................................................................

13

Verifying the inventory........................................................................................................

13

Returning damaged equipment............................................................................................

13

3 Installing the server blade into the enclosure................................................

14

Installation sequence and checklist............................................................................................

14

Installing and powering on the server blade...............................................................................

14

Preparing the enclosure......................................................................................................

14

Removing a c7000 device bay divider.............................................................................

15

Removing a c3000 device bay mini-divider or device bay divider........................................

16

Installing interconnect modules........................................................................................

17

Interconnect bay numbering and device mapping.........................................................

18

Installing the server blade into the enclosure..........................................................................

19

Server blade power states...................................................................................................

20

Powering on the server blade..........................................................................................

21

Powering off the server blade..........................................................................................

21

Installing the Blade Link for BL860c i4, BL870c i4 or BL890c i4 configurations...............................

21

Using iLO 3...........................................................................................................................

25

Accessing UEFI or the OS from iLO 3 MP...................................................................................

25

UEFI Front Page.................................................................................................................

26

Saving UEFI configuration settings...................................................................................

28

Booting and installing the operating system...........................................................................

28

Operating system is loaded onto the server blade..................................................................

28

Operating system is not loaded onto the server blade.............................................................

28

OS login prompt................................................................................................................

28

Installing the latest firmware using HP Smart Update Manager.....................................................

29

4 Operating system procedures.....................................................................

30

Operating systems supported on the server blade.......................................................................

30

Installing the operating system onto the server blade...................................................................

30

Installing the OS from an external USB DVD device or tape device...........................................

30

Installing the OS using HP Ignite-UX.....................................................................................

31

Installing the OS using vMedia............................................................................................

31

Configuring system boot options...............................................................................................

32

Booting and shutting down HP-UX.............................................................................................

32

Adding HP-UX to the boot options list...................................................................................

32

HP-UX standard boot..........................................................................................................

33

Booting HP-UX from the UEFI Boot Manager.....................................................................

33

Booting HP-UX from the UEFI Shell...................................................................................

34

Contents 3

Booting HP-UX in single-user mode.......................................................................................

34

Booting HP-UX in LVM-maintenance mode.............................................................................

34

Shutting down HP-UX..........................................................................................................

34

5 Optional components................................................................................

36

Partner blades........................................................................................................................

36

Hot-plug SAS disk drives..........................................................................................................

37

Installing internal components..................................................................................................

38

Removing the access panel.................................................................................................

38

Processor and heatsink module............................................................................................

39

DIMMs.............................................................................................................................

44

Mezzanine cards...............................................................................................................

49

HP Smart Array P711m Controller.........................................................................................

50

Supercap pack mounting kit...........................................................................................

51

Installing the Supercap mounting bracket..........................................................................

51

Installing the P711m controller board................................................................................

52

Installing the Supercap Pack...........................................................................................

53

Replacing the access panel.................................................................................................

54

Upgrading a conjoined configuration...................................................................................

54

Procedure summary.......................................................................................................

54

Upgrade kit contents......................................................................................................

55

Before getting started.....................................................................................................

55

Supported operating systems.....................................................................................

56

Minimum firmware versions........................................................................................

56

Determining your current firmware revisions..................................................................

56

Rules for server blade internal components...................................................................

60

Upgrading the original server.........................................................................................

61

Existing server blade check........................................................................................

61

Adding resources.....................................................................................................

62

Final hardware check................................................................................................

68

Booting the operating system.....................................................................................

69

Warranty registration................................................................................................

69

Support.......................................................................................................................

69

Blade link and system information parameters...................................................................

70

Operating System Licenses.............................................................................................

70

The Quick Boot option...................................................................................................

71

Possible changes due to VC profile mapping on the upgraded blade server..........................

72

FC SAN connections.................................................................................................

72

FCoE SAN connections.............................................................................................

73

Ethernet network connections.....................................................................................

74

Preserving VC-assigned MAC addresses in HP-UX by enabling Portable Image......................

75

Pre-Upgrade Procedure for PI.....................................................................................

76

Post-Upgrade Procedure for PI....................................................................................

76

6 Troubleshooting........................................................................................

78

Methodology.........................................................................................................................

78

General troubleshooting methodology..................................................................................

78

Executing recommended troubleshooting methodology ..........................................................

80

Basic and advanced troubleshooting tables...........................................................................

81

Troubleshooting tools..............................................................................................................

84

Controls and ports.............................................................................................................

85

Front panel view...........................................................................................................

85

Rear panel view............................................................................................................

85

Server blade LEDs..............................................................................................................

85

Front panel LEDs...........................................................................................................

86

SAS disk drive LEDs.......................................................................................................

87

4Contents

SAS hard drive LED combinations...............................................................................

87

Blade Link LEDs.............................................................................................................

89

Virtual Front Panel LEDs in the iLO 3 TUI................................................................................

89

SUV Cable and Ports..........................................................................................................

91

Connecting to the serial port...........................................................................................

91

Diagnostics.......................................................................................................................

92

General diagnostic tools.....................................................................................................

92

Fault management overview................................................................................................

92

HP-UX Fault management....................................................................................................

92

Errors and error logs...............................................................................................................

93

Event log definitions...........................................................................................................

93

Event log usage.................................................................................................................

93

iLO 3 MP event logs...........................................................................................................

94

SEL review........................................................................................................................

95

Troubleshooting processors......................................................................................................

96

Processor installation order..................................................................................................

96

Processor module behaviors................................................................................................

96

Enclosure information..............................................................................................................

96

Cooling subsystem..................................................................................................................

96

Firmware...............................................................................................................................

96

Identifying and troubleshooting firmware issues......................................................................

97

Verify and install the latest firmware.....................................................................................

97

Troubleshooting the server interface (system console)...................................................................

97

Troubleshooting the environment...............................................................................................

97

7 Removing and replacing components..........................................................

99

Server blade components list....................................................................................................

99

Preparing the server blade for servicing...................................................................................

102

Powering off the server blade............................................................................................

102

Blade Link for BL870c i4 or BL890c i4 configurations...........................................................

102

Removing the Blade Link for BL870c i4 or BL890c i4 configurations...................................

102

Replacing the Blade Link for BL870c i4 or BL890c i4 configurations...................................

103

Blade Link for BL860c i4 configurations..............................................................................

104

Server blade........................................................................................................................

106

Access panel.......................................................................................................................

106

Disk drive blanks..................................................................................................................

107

Removing a disk drive blank..............................................................................................

107

Disk drives...........................................................................................................................

107

DIMM baffle........................................................................................................................

108

DIMMs................................................................................................................................

109

CPU baffle...........................................................................................................................

110

CPU and heatsink module.....................................................................................................

111

SAS backplane....................................................................................................................

114

Server battery......................................................................................................................

114

Mezzanine cards..................................................................................................................

115

ICH mezzanine board...........................................................................................................

116

System board.......................................................................................................................

116

Blade Link............................................................................................................................

117

8 Support and other resources....................................................................

119

Contacting HP......................................................................................................................

119

Before you contact HP......................................................................................................

119

HP contact information.....................................................................................................

119

Subscription service..........................................................................................................

119

Documentation feedback..................................................................................................

119

HP Insight Remote Support Software...................................................................................

120

Contents 5

New and changed information in this edition...........................................................................

120

Typographic conventions.......................................................................................................

120

Standard terms, abbreviations, and acronyms...............................................

122

A RAID configuration and other utilities........................................................

125

Configuring a Smart Array Controller......................................................................................

125

Using the saupdate command...........................................................................................

125

get_mode..................................................................................................................

125

set_mode...................................................................................................................

126

Updating the firmware using saupdate...........................................................................

127

Determining the Driver ID and CTRL ID................................................................................

127

Configuring RAID volumes using the ORCA menu-driven interface...............................................

128

Creating a logical drive....................................................................................................

129

Deleting a logical drive....................................................................................................

130

Useful UEFI command checks............................................................................................

131

UEFI...................................................................................................................................

132

UEFI Shell and HP POSSE commands.................................................................................

132

Drive paths in UEFI...............................................................................................................

135

Using the Boot Maintenance Manager....................................................................................

135

Boot Options...................................................................................................................

136

Add Boot Option........................................................................................................

136

Delete Boot Option......................................................................................................

137

Change Boot Order....................................................................................................

138

Driver Options.................................................................................................................

139

Add Driver Option......................................................................................................

139

Delete Driver Option....................................................................................................

140

Change Driver Order...................................................................................................

140

Console Configuration......................................................................................................

140

Boot From File.................................................................................................................

142

Set Boot Next Value.........................................................................................................

142

Set Time Out Value..........................................................................................................

143

Reset System....................................................................................................................

143

iLO 3 MP.............................................................................................................................

144

B Regulatory information............................................................................

145

Turkey RoHS material content declaration.................................................................................

145

Ukraine RoHS material content declaration..............................................................................

145

Warranty information............................................................................................................

145

Index.......................................................................................................

146

6Contents

1 Overview

The HP Integrity BL860c i4 Server Blade is a dense, low-cost, Intel® Itanium® processor server blade. Using a Blade Link hardware assembly, multiple BL860c i4 Server Blades can be conjoined to create dual-blade, four socket and quad-blade, eight socket variants.

Name

Number of Conjoined Server Blades

Number of Processor Sockets

BL860c i4

1

2

BL870c i4

2

4

BL890c i4

4

8

The three blade configurations support the HP-UX operating system and are designed for deployment in HP c-Class enclosures, specifically the 10U c7000 and the 6U c3000 Enclosures. The nPartition configuration feature is enabled from the factory, enabling the BL870c i4 and BL890c i4 to be partitioned into one more electrically isolated partitions. See the nPartitions Administrator Users Guide for more information.

NOTE: For purposes of this guide, make sure that the c-Class server blade enclosure is powered on and running properly and that the OA and iLO 3 is operational.

Server blade overview

Product

CPU cores (octo)

DIMM slots

BL860c i4

16

24

BL870c i4

32

48

BL890c i4

64

96

 

PCIe I/O

 

 

Mezzanine card

SAS Hard Disk

max memory

capacity

Drives

364GB with

3

2

16GB DIMMs

 

 

768GB with

6

4

16GB DIMMs

 

 

1.5TB with 16GB

12

8

DIMMs

 

 

Server blade overview

7

Server blade components

1

CPU0

8

ICH mezzanine connector

2

CPU0 power connector

9

Mezzanine connector 3 (type 1 or 2)

3

Mezzanine connector 1 (type 1)

10

CPU1 power connector

4

Mezzanine connector 2 (type 1 or 2)

11

CPU1

5

System board thumbscrew

12

SAS backplane

6

System board thumbscrew

13

Pull tab

7

Battery (CR2032)

 

 

NOTE: The iLO 3 password is located on the pull tab.

8Overview

2 Site preparation

The HP Integrity BL860c i4 Server Blade does not have cooling or power systems. Cooling and power is provided by the c-Class enclosure.

IMPORTANT: To avoid hardware damage, allow the thermal mass of the product to equalize to the temperature and humidity of the installation facility after removing the shipping materials. A minimum of one hour per 10°C (50°F) of temperature difference between the shipping facility and installation facility is required

Server blade dimensions and weight

Table 1 Server blade dimensions and weight for the BL860c i4

Dimensions

value

Height

36.63 cm (14.42 in.)

Width

5.14 cm (2.025 in.)

Depth

48.51 cm (19.1 in.)

Weight

Unloaded: 8.6 kg (19 lb)

 

Fully loaded: 11.3 kg (25 lb)

Table 2 Blade Link dimensions and weight

Blade Link type

Height

Width

Weight

BL1 (BL860 i4)

44 mm (1.73 in)

51 mm (2 in)

.5 lb (.22 kg)

BL2 (BL870 i4)

44 mm (1.73 in)

106 mm (4.17 in)

1 lb (.45 kg)

BL4 (BL890 i4)

44 mm (1.73 in)

212 mm (8.34 in)

2 lb (.90 kg)

Enclosure information

All three blade configurations are supported in HP c7000 and c3000 Enclosures. For more enclosure information see: http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0-121.htm.

Enclosure environmental specifications

NOTE: This information is for both c3000 and c7000 Enclosures.

Specification

Value

Temperature range 1

 

Operating

10°C to 35°C (50°F to 95°F)

Non-operating

-30°C to 60°C (-22°F to 140°F)

Wet bulb temperature

 

Operating

28ºC (82.4ºF)

Non-operating

38.7ºC (101.7ºF)

Relative humidity (noncondensing)2

 

Server blade dimensions and weight

9

Operating

20% to 80%

Non-operating

5% to 95%

1All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048 m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.

2Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.

For more information on the c-Class enclosures, go to http://h71028.www7.hp.com/enterprise/ cache/316735-0-0-0-121.htmlf.

For more site preparation information, go to http://www.hp.com/go/Blades-docs, select HP Integrity BL860c i4 Server Blade in the list of servers, and then select the Generalized Site Preparation Guidelines.

Sample Site Inspection Checklist

 

 

Table 3 Customer and HP Information

 

 

Customer Information

 

 

Name:

 

Phone number:

 

Street address:

City or Town:

 

State or province:

Country

 

Zip or postal code:

 

 

Primary customer contact:

Phone number:

 

Secondary customer contact:

Phone number:

 

Traffic coordinator:

Phone number:

 

 

 

HP information

 

Sales representative

Order number:

 

Representative making survey

Date:

 

Scheduled delivery date

 

 

Table 4 Site Inspection Checklist

 

 

Check either Yes or No. If No, include comment number or date.

Comment or Date

Computer Room

 

 

Number

Area or condition

Yes

No

1.

Is there a completed floor plan?

 

 

2.Is adequate space available for maintenance needs? Front 36 inches (91.4 cm) minimum and rear 36 inches (91.4 cm) minimum are recommended clearances.

3. Is access to the site or computer room restricted?

4.Is the computer room structurally complete? Expected date of completion?

5. Is a raised floor installed and in good condition? 6. Is the raised floor adequate for equipment loading? 7. Are channels or cutouts available for cable routing?

10 Site preparation

Table 4 Site Inspection Checklist (continued)

Check either Yes or No. If No, include comment number or date.

Comment or Date

8.

Is a network line available?

 

9.

Is a telephone line available?

 

10.Are customer-supplied peripheral cables and LAN cables available and of the proper type?

11. Are floor tiles in good condition and properly braced?

12.Is floor tile underside shiny or painted? If painted, judge the need for particulate test.

Power and Lighting

 

Number

Area or Condition

Yes No

13.

Are lighting levels adequate for maintenance?

 

14. Are AC outlets available for servicing needs (for example, laptop)? 15. Does the input voltage correspond to equipment specifications?

15a. Is dual source power used? If so, identify types and evaluate grounding.

16. Does the input frequency correspond to equipment specifications?

17. Are lightning arrestors installed inside the building?

18. Is power conditioning equipment installed? 19. Is a dedicated branch circuit available for equipment?

20. Is the dedicated branch circuit less than 75 feet (22.86 m)?

21.

Are the input circuit breakers adequate for equipment loads?

 

 

Safety

 

 

 

Number

Area or Condition

Yes

No

22. Is an emergency power shutoff switch available? 23. Is a telephone available for emergency purposes?

24. Does the computer room have a fire protection system? 25. Does the computer room have antistatic flooring installed?

26.Do any equipment servicing hazards exist (loose ground wires, poor lighting, and so on)?

Cooling

 

 

Number

Area or Condition

Yes No

27.Can cooling be maintained between 5°C (41 °F) and 35°C (95 °F) (up to 1,525 m/5,000 ft)? Derate 1°C/305 m (34 °F/1,000 ft) above 1,525 m/5,000 ft and up to 3,048 m/10,000 ft.

28.Can temperature changes be held to 5°C (9 °F) per hour with tape media? Can temperature changes be held to 20°C (36 °F) per hour without tape media?

29.Can humidity level be maintained at 40% to 55% at 35°C (95 °F) noncondensing?

30. Are air-conditioning filters installed and clean?

Storage

Sample Site Inspection Checklist

11

Table 4 Site Inspection Checklist (continued)

Check either Yes or No. If No, include comment number or date.

Comment or Date

Number

Area or Condition

Yes No

31.

Are cabinets available for tape and disc media?

 

32.

Is shelving available for documentation?

 

Training

 

 

Number

Area or Condition

 

33.

Are personnel enrolled in the System Administrator’s Course?

 

34.

Is on-site training required?

 

Power subsystem

The power subsystem is located on the system board. The BL860c i4 Server Blade receives 12 Volts directly from the enclosure. The voltage is immediately passed through an E-fuse circuit, which will immediately cut power to the blade if a short circuit fault or over current condition is detected. The E-fuse can also be intentionally power cycled through the manageability subsystem. The 12V is distributed to various points on the blade and is converted to lower voltages through power converters for use by integrated circuits and loads on the blade.

ESD handling information

CAUTION: Wear an ESD wrist strap when handling internal server components. Acceptable ESD wrist straps include:

The wrist strap that is included in the ESD kit with circuit checker (part number 9300-1609).

The wrist strap that is included in the ESD kit without circuit checker (part number 9300-1608).

If the above options are unavailable, the throw away (one use only) strap that ships with some HP memory products can also be used, with increased risk of electrostatic damage.

When removing and replacing server components, use care to prevent injury and equipment damage. Many assemblies are sensitive to damage by electrostatic discharge.

Follow the safety precautions listed to ensure safe handling of components, to prevent injury, and to prevent damage to the server blade:

When removing or installing a server blade or server blade component, review the instructions provided in this guide.

Do not wear loose clothing that might snag or catch on the server or on other items.

Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.

If installing an internal assembly, wear an antistatic wrist strap, and use a grounding mat such as those included in the Electrically Conductive Field Service Grounding Kit.

Handle components by the edges only. Do not touch any metal-edge connectors or electrical components on accessory boards.

Unpacking and inspecting the server blade

Be sure that you have adequately prepared your environment for your new server blade, received the components that you ordered, and verified that the server and the containers are in good condition after shipment.

12 Site preparation

Verifying site preparation

Verifying site preparation is an essential factor of a successful server blade installation, and includes the following tasks:

Gather LAN information. Determine the two IP addresses for the iLO 3 MP LAN and the server blade LAN.

Establish a method to connect to the server blade console. For more information on console connection methods, see “Using iLO 3” (page 25) for more information.

Verify electrical requirements. Be sure that grounding specifications and power requirements are met.

Confirm environmental requirements.

Inspect the shipping containers for damage

HP shipping containers protect their contents under normal shipping conditions. After the equipment arrives, carefully inspect each carton for signs of shipping damage. Shipping damage constitutes moderate to severe damage such as punctures in the corrugated carton, crushed boxes, or large dents. Normal wear or slight damage to the carton is not considered shipping damage. If you find shipping damage to the carton, contact your HP customer service representative immediately.

Unpacking the server blade

1.Use the instructions printed on the outside top flap of the carton.

2.Remove inner accessory cartons and the top foam cushions.

IMPORTANT: Inspect each carton for shipping damage as you unpack the server blade.

3.Place the server blade on an antistatic pad.

Verifying the inventory

The sales order packing slip lists the equipment shipped from HP. Use this packing slip to verify that the equipment has arrived.

NOTE: To identify each item by part number, see the sales order packing slip.

Returning damaged equipment

If the equipment is damaged, immediately contact your HP customer service representative. The service representative initiates appropriate action through the transport carrier or the factory and assists you in returning the equipment.

Unpacking and inspecting the server blade 13

3 Installing the server blade into the enclosure

Installation sequence and checklist

Step

Description

Completed

1

Perform site preparation (see “Site preparation” (page 9)for more information).

 

2Unpack and inspect the server shipping container and then inventory the contents using the packing slip.

3Install additional components shipped with the server. For these procedures, see the documentation that with the component or the user service guide.

4 Install and power on the server blade.

5 Configure iLO 3 MP access.

6 Access iLO 3 MP.

7 Access UEFI from iLO 3 MP.

8 Download latest firmware and update using HP Smart Update Manager 9 Install and boot the OS.

NOTE: For more information regarding HP Integrity Server Blade upgrades, see “Upgrading a conjoined configuration” (page 54)for more information.

Installing and powering on the server blade

Preparing the enclosure

HP BladeSystem enclosures ship with device bay dividers to support half-height devices. To install a full height device, remove the blanks and the corresponding device bay divider.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade or the enclosure unless all hard drive and device bays are populated with either a component or a blank.

1.Remove the device bay blank.

14 Installing the server blade into the enclosure

2.Remove the three adjacent blanks.

Removing a c7000 device bay divider

1.Slide the device bay shelf locking tab to the left to open it.

2.Push the device bay shelf back until it stops, lift the right side slightly to disengage the two tabs from the divider wall, and then rotate the right edge downward (clockwise).

Installing and powering on the server blade 15

3.Lift the left side of the device bay shelf to disengage the three tabs from the divider wall, and then remove it from the enclosure.

Removing a c3000 device bay mini-divider or device bay divider

1.Slide the locking tab down.

16 Installing the server blade into the enclosure

2.Remove the mini-divider or divider:

c3000 mini-divider:

Push the divider toward the back of the enclosure until the divider drops out of the enclosure.

c3000 divider

a.Push the divider toward the back of the enclosure until it stops.

b.Slide the divider to the left to disengage the tabs from the wall.

c.Rotate the divider clockwise.

d.Remove the divider from the enclosure.

Installing interconnect modules

For specific steps to install interconnect modules, see the documentation that ships with the interconnect module.

Installing and powering on the server blade 17

HP BL860c i4, BL870c i4, BL890c i4 User Manual
Interconnect bay numbering and device mapping

HP BladeSystem c7000 Enclosure

HP BladeSystem c3000 Enclosure

To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals.

Server blade signal

c7000 interconnect bay

c3000 interconnect bay

Interconnect bay labels

NIC 1 (Embedded)

1

1

 

NIC 2 (Embedded)

2

1

 

NIC 3 (Embedded)

1

1

 

NIC 4 (Embedded)

2

1

 

Mezzanine 1

3 and 4

2

 

18 Installing the server blade into the enclosure

Server blade signal

c7000 interconnect bay

c3000 interconnect bay

Interconnect bay labels

Mezzanine 2

5 and 6

3 and 4

 

 

7 and 8

3 and 4

 

Mezzanine 3

5 and 6

3 and 4

 

 

7 and 8

3 and 4

 

For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the HP BladeSystem enclosure setup and installation guide for your product on the HP website (http://www.hp.com/go/bladesystem/documentation).

Installing the server blade into the enclosure

NOTE: When installing additional blades into an enclosure, additional power supplies might also be needed to meet power requirements. For more information, see the HP BladeSystem enclosure setup and installation guide for your product on the HP website (http://www.hp.com/ go/bladesystem/documentation).

NOTE: Before installing and initializing the server blade, install any server blade options, such as an additional processor, hard drive, or mezzanine card.

1.Remove the connector covers if they are present.

2.Prepare the server blade for installation.

Installing and powering on the server blade 19

3.Install the server blade.

The server blade should come up to standby power. The server blade is at standby power if the blade power LED is amber.

Server blade power states

The server blade has three power states: standby power, full power, and off. Install the server blade into the enclosure to achieve the standby power state. Server blades are set to power on to standby power when installed in a server blade enclosure. Verify the power state by viewing the LEDs on the front panel, and using Table 5.

Table 5 Power States

Power States

Server Blade Installed

Front Panel Power

Standby Power

DC Power Applied?

 

in Enclosure?

Button Activated?

Applied?

 

Standby power

Yes

No

Yes

No

Full power

Yes

Yes

Yes

Yes

Off

No

No

No

No

20 Installing the server blade into the enclosure

Powering on the server blade

Use one of the following methods to power on the server blade:

NOTE: To power on blades in a conjoined configuration, only power on the Monarch blade. See “ Blade Link bay location rules” for rules on the definition of the Monarch blade.

Use a virtual power button selection through iLO 3.

Press and release the Monarch power button.

When the server blade goes from the standby mode to the full power mode, the blade power LED changes from amber to green.

For more information about iLO 3, see “Using iLO 3” (page 25).

Powering off the server blade

Before powering down the server blade for any upgrade or maintenance procedures, perform a backup of critical server data and programs.

Use one of the following methods to power off the server blade:

NOTE: To power off blades in a conjoined configuration, only power off the Monarch blade.

Use a virtual power button selection through the iLO 3 GUI (Power Management, Power & Reset) or the iLO 3 TUI commands.

This method initiates a controlled remote shutdown of applications and the OS before the server blade enter standby mode.

Press and release the Monarch power button.

This method initiates a controlled shutdown of applications and the OS before the server blade enter standby mode.

Press and hold the Monarch power button for more than 4 seconds to force the server blade to enter standby mode.

This method forces the server blade to enter standby mode without properly exiting applications and the OS. It provides an emergency shutdown method in the event of a hung application.

Installing the Blade Link for BL860c i4, BL870c i4 or BL890c i4 configurations

IMPORTANT: Without an attached Blade Link, the server blades will not power on.

Installing the Blade Link for BL860c i4, BL870c i4 or BL890c i4 configurations 21

NOTE: Before installing the Blade Link for BL870c i4 or BL890c i4, make sure the following statements are true:

All blades have the same CPU SKUs

All blades have the same hardware revision (only use BL860c i4, BL870c i4, or BL890c i4 Server Blades)

All blades have CPU0 installed

All blades have the same firmware revision set

All blades follow the memory loading rules for your configuration, see “DIMMs” (page 44)

The enclosure OA firmware is compatible with the blade firmware

The Monarch blade has an ICH mezzanine card installed

The proper Blade Link is being used for your configuration

To check on the blade hardware revisions and CPU SKUs, go to the Command Menu in the iLO 3 TUI and enter the DF command. This dumps the FRU content of the blades.

NOTE: If you will be upgrading an initial installation, see the user service guide for more information on server blade upgrades.

Blade Link bay location rules

 

 

 

 

 

Partner blade

 

 

 

 

 

half-height bay

 

Number of

 

 

 

number / Server

 

conjoined

Supported

 

Partner blade

blade full-height bay

Class

blades

enclosures

Blade location rules

support?

number

BL1

1 (standard

c7000

No specific bay

Yes

Bottom half-height

 

for BL860c

 

location rules for

 

adjacent bay, paired

 

i4)

 

blades

 

with the server blade

 

 

 

 

 

in full-height bays

 

 

 

 

 

1&2, 3&4, 5&6, or

 

 

 

 

 

7&8

c3000

BL2

2 (BL870c i4) c7000

Bays 1&2, 3&4,

No

 

 

5&6, or 7&8 with

 

 

 

Monarch blade in

 

 

 

odd bay

 

Half-height bay 8, paired with the server blade in full-height bay 3.

CAUTION: The bay mini-divider must be installed in the c3000 enclosure to ensure the partner blade is inserted correctly. Failure to install the bay mini-divider might result in damage to the blade or enclosure when installing the partner blade.1

N/A

22 Installing the server blade into the enclosure

 

 

 

 

Partner blade

 

 

 

 

half-height bay

 

Number of

 

 

number / Server

 

conjoined

Supported

Partner blade

blade full-height bay

Class

blades

enclosures

Blade location rules support?

number

 

 

c3000

Bays 1&2, 3&4

 

 

 

 

with Monarch blade

 

 

 

 

in odd bay

 

BL2E

2 (BL870c i4) c7000 only

Bays 2&3, 4&5 or Yes

 

 

6&7 with Monarch

 

 

blade in even bay

 

 

using full-height

 

 

numbering

2 (BL870c i4) c3000 only

Bays 2&3 with

No

 

Monarch blade in

 

 

even bay using

 

 

full-height

 

 

numbering.

 

Bottom half-height bay 9 paired with full-height bays 2&3, bottom half-height bay 11 paired with full-height bays 4&5, bottom half-height bay 13 paired with full-height bays 6&7

N/A

BL4

4 (BL890c i4)

c7000 only

Bays 1&2&3&4 or

No

N/A

 

 

 

5&6&7&8, with

 

 

 

 

 

Monarch blade

 

 

 

 

 

defaulting to slot 1

 

 

 

 

 

or slot 5,

 

 

 

 

 

respectively

 

 

 

4 (BL890c i4)

c3000 only

Bays 1&2&3&4

No

N/A

 

 

 

with Monarch blade

 

 

 

 

 

defaulting to slot 1

 

 

1For information on installing the c3000 bay mini-divider, see the HP BladeSystem c3000 Enclosure Setup and Installation Guide.

CAUTION: Using the incorrect Blade Link can cause damage to the Blade Link and to the connectors on both the Blade Link and the server blades.

IMPORTANT: Failure to follow bay location rules can prevent server blade power on.

NOTE: The manufacturing part numbers for the Blade Link is located on a sticker on the PCA.

“Upgrading a conjoined configuration” (page 54)

To install the Blade Link:

1.Log on to the OA.

2.Install the first blade into the lowest bay number, this blade becomes the Monarch blade (“Installing the server blade into the enclosure”).

3.Wait 10 seconds. The IP address of the installed blade appears in the OA.

4.Insert each adjacent blade, waiting 10 seconds between blades.

NOTE: The blades will go into stand-by

5.Using the OA, verify that the rest of the blades that will be conjoined have an IP address and are powered off.

6.Remove the plastic protectors from the connectors on the back of the Blade Link.

7.Push in the blue release latch on the handle to release the handle.

Installing the Blade Link for BL860c i4, BL870c i4 or BL890c i4 configurations 23

8.Pull the handle all the way out

9.Align the guide pins on the back of the Blade Link to the holes on the front of the server blades. As you insert the pins into the holes, ensure the face on the Blade Link is evenly aligned parallel to the face of the server blades.

10.Press firmly on the left and right sides of the Blade Link face until the handle naturally starts to close.

CAUTION: If not properly aligned, you can damage the Blade Link

11. Close the handle when it has engaged.

12.Log into iLO 3 on the Monarch blade. For more information, see the HP Integrity iLO3 Operations Guide.

13.In iLO 3, go to the Command Menu and execute xd -r to reboot all of the iLO 3s in the conjoined set.

14.Run the conjoin checks

Integrity BL870c i4 and BL890c i4 systems go through a process called “conjoining” when the Blade Link is attached. The system cannot boot until that process is completed properly.

a.Execute the following CM commands in the iLO 3 TUI to show data from all blades. This information can be used to determine if the blades are successfully conjoined:

i.DF— Lists the FRUs on all of the blades (2 or 4).

ii.SR — Shows a table of each blades firmware revisions.

iii.Blade— Shows information about the OA and the bays used.

b.Check to see if the OA shows a properly conjoined system from its GUI.

IMPORTANT: The secondary UUID and other system variables are stored on the Monarch blade. If you do not put the Monarch blade in the leftmost slot, your system variables will not match. If you ever change your iLO 3 configuration (such as adding users) that data is also stored on the Monarch blade.

NOTE: Auxiliary blades are not slot dependent after being installed and configured, however when the conjoined systems ship, they come with A, B, C, D stickers located under the Blade Links. While auxiliary blades are not slot dependent after being installed and configured, HP recommends using the shipped order to ensure proper auxiliary blade function.

24 Installing the server blade into the enclosure

15.Still in the iLO 3 Command Menu, power on the Monarch blade with the PC -on -nc command. Powering on the Monarch blade will power the entire conjoined system on.

16.Boot the Monarch blade. Booting the Monarch blade boots the entire conjoined system.

Using iLO 3

The iLO 3 subsystem is a standard component of selected server blades that monitors blade health and provides remote server manageability. The iLO 3 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 3 independent of the host server and operating system. The iLO 3 subsystem provides remote access to any authorized network client, sends alerts, and provides other server management functions.

Using iLO 3, you can:

Remotely power on, power off, or reboot the host server.

Subscribe to we-man alerts from iLO 3 regardless of the state of the host server.

Access advanced troubleshooting features through the iLO 3 interface.

Access Remote Console and vMedia functionality.

For more information about iLO 3 basic features, see the iLO 3 documentation on the HP website (http://h20341.www2.hp.com/integrity/w1/en/software/integrity-lights-out.html? jumpid=ex_r11294_us/en/large/tsg/go_integrityilo).

Accessing UEFI or the OS from iLO 3 MP

UEFI is an architecture that provides an interface between the server blade OS and the server blade firmware. UEFI provides a standard environment for booting an OS and running preboot applications.

Use this procedure to access UEFI or the OS from the iLO 3 MP. Your security parameters were set regarding remote access.

1.Retrieve the factory iLO 3 password from the iLO 3 Network pull tag located on the right side of the Monarch blade.

2.From the MP Main Menu, enter the co command to access the Console.

NOTE: Terminal windows should be set to a window size of 80 columns x 25 rows for optimal viewing of the console at UEFI.

3.After memory test and CPU late self test the following message appears:

Press Ctrl-C now to bypass loading option ROM UEFI drivers.

The prompt will timeout if Ctrl-C is not pressed within a few seconds. If Ctrl-C is pressed, you will be presented with two options:

Bypass loading from I/O slots.

Bypass loading from I/O slots and core I/O.

The Bypass loading from I/O slots and core I/O option may be useful if a bad core I/O UEFI driver is preventing system boot. USB drives can still be used at the UEFI shell to update core I/O drivers.

CAUTION: Hitting Ctrl-C before the prompt will not work and may even disable this feature, be sure wait for the prompt before hitting Ctrl-C.

NOTE: It can take several minutes for this prompt to appear, and the window of time when Ctrl-C can be pressed is very short. For typical boots, HP recommends that you let the prompt time out.

After selecting an option, boot will proceed.

Using iLO 3 25

NOTE: If no option is selected, normal boot will proceed after ten seconds.

4.Depending on how the server blade was configured from the factory, and if the OS is installed at the time of purchase, you are taken to:

UEFI shell prompt

OS login prompt

If the server blade has a factory-installed OS, you can interrupt the boot process to configure your specific UEFI parameters.

If you are at the UEFI shell prompt, go to “UEFI Front Page” (page 26).

If you are at the OS login prompt, go to “OS login prompt” (page 28).

UEFI Front Page

If you are at the UEFI shell prompt, enter exit to get to the UEFI Front Page.

To view boot options, or launch a specific boot option, press B or b to launch the Boot Manager.

26 Installing the server blade into the enclosure

To configure specific devices, press D or d to launch the Device Manager. This is an advanced feature and should only be performed when directed.

To perform maintenance on the system such as adding, deleting, or reordering boot options, press M or m to launch the Boot Maintenance Manager.

Accessing UEFI or the OS from iLO 3 MP 27

To perform more advanced operations, press S or s to launch the UEFI Shell.

To view the iLO 3 LAN configuration, press I or i to launch the iLO 3 Setup Tool.

Saving UEFI configuration settings

There are other UEFI settings you can configure at this time. For more UEFI configuration options, see Appendix A (page 125).

Booting and installing the operating system

From the UEFI Front Page prompt, you can boot and install in either of two manners:

If your OS is loaded onto your server blade, see “Operating system is loaded onto the server blade” (page 28).

If the OS is not installed onto your server blade, see “Operating system is not loaded onto the server blade” (page 28).

Operating system is loaded onto the server blade

If the OS is loaded on your server blade, normally UEFI will automatically boot to the OS. If the UEFI Front Page is loaded, press ENTER to start auto boot, or B or b to select a specific boot option for your OS.

Use your standard OS logon procedures, or see your OS documentation to log on to your OS.

Operating system is not loaded onto the server blade

There are two options on how to load the OS if it is not loaded onto your server blade.

To load the OS from a DVD, see “Installing the OS from an external USB DVD device or tape device” (page 30).

To load the OS using Ignite-UX, see “Installing the OS using HP Ignite-UX” (page 31).

OS login prompt

If your server blade is at the OS login prompt after you establish a connection to the server blade, use your standard OS log in procedures, or see your OS documentation for the next steps.

28 Installing the server blade into the enclosure

Installing the latest firmware using HP Smart Update Manager

The HP Smart Update Manager utility enables you to deploy firmware components from either an easy-to-use interface or a command line. It has an integrated hardware discovery engine that discovers the installed hardware and the current versions of firmware in use on target servers. This prevents extraneous network traffic by only sending the required components to the target. HP Smart Update Manager also has logic to install updates in the correct order and ensure all dependencies are met before deployment of a firmware update. It also contains logic to prevent version-based dependencies from destroying an installation and ensures updates are handled in a manner that reduces any downtime required for the update process. HP Smart Update Manager does not require an agent for remote installations.

Key features of HP Smart Update Manager are:

GUI and CLI–command line interface

Dependency checking, which ensures appropriate installation order and dependency checking between components

Intelligent deployment deploys only required updates

Support for updating firmware on network-based targets, such as the OA, iLO (through the Network Management Port), and VC Ethernet modules

Improved deployment performance

Remote command-line deployment

Windows X86 or Linux X86 support

HP Smart Update Manager is included in the firmware bundles download from http://www.hp.com, and is supported on the BL860c i4, BL870c i4, and BL890c i4.

For more information about HP Smart Update Manager, see the HP Smart Update Manager User Guide (www.hp.com/support/HP_Smart_Update_Manager_UG_en).

Installing the latest firmware using HP Smart Update Manager 29

4 Operating system procedures

Operating systems supported on the server blade

HP-UX 11i v3 HWE 1209

Installing the operating system onto the server blade

The following procedures describe generalized operating system installation. For more details, see the operating system documentation.

Installing the OS from an external USB DVD device or tape device

NOTE: Tapeboot requires BL8x0c i4 system firmware bundle 42.06 or later and a partner tape blade, or an additional 51378-B21 Integrity Smart Array P711m HBA running 6.22 firmware or later to boot from an Ultrium 6250 tape drive.

1.If using an external USB DVD device:

a.Connect the Integrity SUV cable to the front of the Monarch server blade.

b.Connect the USB DVD cable to one of the USB ports on the SUV cable.

NOTE: Some DVD drives might also require a separate power connection.

c.Turn on the external USB DVD device.

2.Insert the OS media into the USB DVD device or tape device.

3.Power on the server blade and boot to UEFI. If the server blade is already powered on, then reboot to UEFI using the reset command at the UEFI prompt.

4.From the UEFI Front Page, press S or s to launch the UEFI Shell.

NOTE: If the device is already selected or you already know the device name, then skip the following step.

If you are using a tape device, when the UEFI shell comes up, you should see a message similar to the following on the console:

HP Smart Array

P212 Controller

(version 6.22)

Tape Drive(s) Detected:

 

 

Port: 1I,

box:0, bay: 3

(SAS)

 

The message may also be similar to the following.

HP Smart Array

P711m Controller

(version 6.22) 0 Logical Drives

Tape Drive(s) Detected:

 

 

Port: 2E,

box:1, bay: 9

(SAS)

 

NOTE:

If you do not see a line starting with Port and ending with (SAS), the tape is not connected correctly or it is not responding.

30 Operating system procedures