Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

For: 220-230V~, 50Hz

 

 

Indoor

Maximum:D.B/W.B

32oC/23oC

Cooling

Minimum:D.B/W.B

18oC/14oC

 

 

 

 

Outdoor

Maximum:D.B/W.B

52oC/31oC

 

 

Minimum:D.B

18oC

 

 

Indoor

Maximum:D.B

27oC

 

Heating

 

Minimum: D.B

15oC

 

Outdoor

Maximum:D.B/W.B

27oC/18oC

 

 

 

 

 

Minimum:D.B

-7oC

For: 220V~, 60Hz

 

Indoor

Maximum: D.B / W.B

29oC/19oC

Cooling

 

Minimum: D.B / W.B

18oC/14oC

Outdoor

Maximum: D.B / W.B

54oC/24oC

 

 

Minimum: D.B

18oC

 

Indoor

Maximum: D.B

27oC

Heating

Minimum: D.B

15oC

Outdoor

Maximum: D.B / W.B

24oC/18oC

 

Minimum: D.B / W.B

-7oC/-8oC

2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised

to ensure that they do not play with the applience.

9.Please employ the proper power plug, which fit into the power supply cord.

10 .The power plug and connecting cable must have acquired the local attestation.

11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

CAUTION

Connect the earth

Do not install in the

Do not get the unit

Check proper

cable.

place where there is

exposed to vapor

installation of the

 

any possibility of

or oil steam.

drainage securely

 

inflammable gas

 

 

 

leakage around the

 

 

 

unit.

 

 

earthing

 

 

 

 

 

 

STRICT

 

PROHIBITION

PROHIBITION

ENFORCEMENT

Haier HSU-18HEA03, HSU-18LEA03, HSU-18LEA13 Manual

Cautions

 

WARNING

 

When abnormality such as burnt-small found,

Use an exclusive power source with a

immediately stop the operation button and

circuit breaker

 

contact sales shop.

 

 

 

OFF

STRICT

 

 

 

ENFORCEMENT

 

 

Connect power supply cord

Use the proper voltage

Do not use power supply cord

to the outlet completely

 

 

extended or connected in halfway

 

 

 

STRICT

 

STRICT

PROHIBITION

ENFORCEMENT

 

ENFORCEMENT

 

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.

CAUTION

Take fresh air occasionally especially

Do not operate the switch with

when gas appliance is running at the

wet hand.

same time.

 

PROHIBITION

Do not install the unit near a fireplace or other heating apparatus.

PROHIBITION

Do not place animals or plants in the direct path of the air flow

STRICT

ENFORCEMENT

Check good condition of the installation stand

PROHIBITION

Do not place any objects on or climb on the unit.

PROHIBITION

Do not pour water onto the unit for cleaning

PROHIBITION

Do not place flower vase or water containers on the top of the unit.

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor Unit

Display board

Inlet

Air Purifying Filter

(inside)

Inlet grille

Horizontal flap

(adjust up and down air flow. Don't adjust it manually)

Anion generator (inside)

Outlet

Air filter(inside)

Power plug

Vertical blade

(adjust left and right air flow)

Actual inlet grille may vary from the one shown in the manual according to the product purchased

Outdoor Unit

HSU-12HEB03

OUTLET

INLET

HSU-18HEA13(T3) HSU-09HEA03

HSU-18HEA03(T3) HSU-12HEA03 HSU-18LEA13(T3) HSU-18LEA03(T3)

CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE

5