Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts

out and gets into eyes, it may result in serious eye injuries.

1

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the applience.

9.Please employ the proper power plug, which fit into the power supply cord.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum:D.B/W.B

32oC/23oC

 

Minimum:D.B/W.B

18oC/14oC

Cooling

 

 

 

Outdoor

Maximum:D.B/W.B

43oC/26oC

 

Minimum:D.B

18oC

 

Indoor

Maximum:D.B

27oC

 

Minimum:D.B

15oC

Heating

 

Outdoor

Maximum:D.B/W.B

24oC/18oC

 

 

Minimum:D.B/W.B

-15oC

 

 

2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

10 .The power plug and connecting cable must have acquired the local attestation.

11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

 

CAUTION

Connect the earth

Do not install in the

Do not get the unit

cable.

place where there is

exposed to vapor

 

any possibility of

or oil steam.

 

inflammable gas

 

 

leakage around the

 

 

unit.

 

earthing

 

 

 

PROHIBITION

PROHIBITION

Check proper installation of the drainage securely

STRICT

ENFORCEMENT

3

Haier HSU-07HV03, HSU-09HV03, HSU-12HV03, HSU-18HV03, HSU-22HV03 User Manual

Cautions

WARNING

When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.

OFF

STRICT

 

ENFORCEMENT

Use an exclusive power source with a circuit breaker

Connect power supply cord

Use the proper voltage

Do not use power supply cord

to the outlet completely

 

extended or connected in halfway

 

 

STRICT

STRICT

PROHIBITION

ENFORCEMENT

ENFORCEMENT

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of storage of

Take fresh air occasionally especially

Do not operate the switch with

food, art work, precise equipment,

when gas appliance is running at the

wet hand.

breeding, or cultivation.

same time.

 

 

STRICT

PROHIBITION

PROHIBITION

ENFORCEMENT

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand

for cleaning

 

 

PROHIBITION

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow

climb on the unit.

containers on the top of the unit.

 

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor unit

Display board

Outlet

Inlet

Air filter(inside)

Air Purifying Filter

 

(inside)

 

Inlet grille

 

 

Anion generator

Vertical flap

(inside)

 

(adjust up and down air flow.

Power plug

Don't adjust it manually)

Horizontal louver

 

(adjust left and right air flow)

 

For 22k unit, the power plug is on the outdoor unit

Outdoor unit

HSU-07HV03/R2(DB)

HSU-09HV03/R2(DB) HSU-22HV03/R2(DB) HSU-12HV03/R2(DB)

HSU-18HV03/R2(DB)

HSU-12HVB03/R2(DB)

1

OUTLET

3

CONNECTING PIPING AND ELECTRICAL WIRING

2

INLET

4

DRAIN HOSE

5

Parts and Functions

19

28

30

1.RESET

When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.

2.LIGHT button

Control the lightening and extinguishing of the indoor LED display board.

3. TIMER button

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.

4. CLOCK button

Used to set correct time.

5. SLEEP button

Used to select sleep mode.

6. MODE button

AUTO COOL DRY FAN HEAT

7.HOUR button

Used to set clock and timer setting.

8.HEALTH button

Used to set healthy operation.

9.ON/OFF button

Used for unit start and stop.

16

31

10

14

21

15

10. TIMER ON display

11. FAN SPEED display

LOW

MED

HI

AUTO

12.LOCK display

13.SWING UP/DOWN display

14.SLEEP display

15.HEALTH display

16.Operation mode display

Operation mode AUTO COOL DRY HEAT FAN

Remote controller

Display board

17.Singal sending display

18.POWER/SOFT display

19.Left/right air flow display

20.TEMP display

Remote controller: to display the TEMP. setting.

21.TIMER OFF display

22.TIMER display

23.TEMP button

Used to select your desired temperature.

24.FAN button

Used to select fan speed: LOW,MED, HI, AUTO.

25.HEALTH AIRFLOW button

Used to set the health airflow mode.

26.SWING UP/DOWN button

Used to select up or down air sending direction.

27.SWING LEFT/RIGHT button

Used to select left/right air flow.

28.SET button

Used to confirm timer and clock settings.

29.POWER/SOFT button

Every time the button is pressed,display changes

as follows:

BLANK

POWER SOFT

30. LOCK

Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.

31. Ambient temp.display

When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.

NOTE:Cooling only unit do not have functions and displays related with heating.

6

Parts and Functions

Clock Set

 

 

When unit is started for the first time and after replacing batteries in

 

remote controller, clock should be adjusted as follows:

 

1. Press CLOCK button,"AM" or "PM" flashes.

 

2. Press or

to set correct time. Each press will increase or decrease

POWER/SOFT

1 min. If the button is kept depressed, time will change quickly.

3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.

Remote controller's operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit.

The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.

Don't throw or knock the remoter controller.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Loading of the battery

Load the batteries as illustrated right 2 R-03 (7#) batteries

Remove the battery cover:

Slightly press" "area and push down the cover as illustrated.

Load the battery:

Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case.

Put on the cover again.

Confirmation indicator:

After pressing power ON/OFF, if no display, reload the batteries.

Note:

Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.

Used two new same-typed batteries when loading.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.

7

Operation

HEALTH operation

Remote controller

1.Unit start

Press ON/OFF on the remote controller, unit starts.

2.Health anion function

Press HEALTH button. For each press, is displayed. Air conditioner starts health anion function operation.

For twice press, disappears,the operation stops.

POWER/SOFT

When indoor fan motor is running, it has healthy process function. (It's available under any mode)

When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.

BRIEF INTRODUCTION TO HEALTH ANION FUCTION

The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.

8