SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09C03/VA(ZXF)
HSU-09H03/VA(ZXF)
HSU-12C03/VA(ZXF)
HSU-12H03/VA(ZXF)
HSU-18C03/V(ZXF)
HSU-18H03/V(ZXF)
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
Please read this operation manual before using the air conditioner
No.0010554404
Cautions
Disposal of the old air conditioner |
Safety Instructions and Warnings |
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled
.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
7.The appliance is not intended for use by young children or infirm persons without supervision.
8.Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
10 .The power plug and connecting cable must have acquired the local attestation.
1.Applicable ambient temperature range:
|
Indoor |
Maximum:D.B/W.B |
32oC/23oC |
|
|
Minimum:D.B/W.B |
18oC/14oC |
||
Cooling |
|
|
|
|
Outdoor |
Maximum:D.B/W.B |
43oC/26oC |
||
|
Maximum:D.B |
18oC |
||
|
Indoor |
Maximum:D.B |
27oC |
|
|
Maximum:D.B |
15oC |
||
Heating |
|
|||
Outdoor |
Maximum:D.B/W.B |
24oC/18oC |
||
|
||||
|
Minimum:D.B/W.B |
-7oC/-8oC |
||
|
|
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4.The wiring method should be in line with the local wiring standard.
5.After installation, the power plug should be easily reached.
6.The waste battery should be disposed properly.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
|
CAUTION |
|
Connect the earth |
Do not install in the |
Do not get the unit |
cable. |
place where there is |
exposed to vapor |
|
any possibility of |
or oil steam. |
|
inflammable gas |
|
|
leakage around the |
|
|
unit. |
|
earthing |
|
|
|
PROHIBITION |
PROHIBITION |
Check proper installation of the drainage securely
STRICT
ENFORCEMENT
3
Cautions
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF |
STRICT |
|
ENFORCEMENT
Use an exclusive power source with a circuit breaker
Connect power supply cord |
Use the proper voltage |
Do not use power supply cord |
|
to the outlet completely |
|
extended or connected in halfway |
|
|
|
||
STRICT |
STRICT |
PROHIBITION |
|
ENFORCEMENT |
ENFORCEMENT |
||
|
|||
Do not use power supply cord |
Take care not to damage |
Do not insert objects into the air |
|
in a bundle. |
the power supply cord. |
inlet or outlet. |
|
PROHIBITION |
PROHIBITION |
PROHIBITION |
|
Do not start or stop the |
Do not channel the air flow directly |
Do not try to repair or reconstruct |
|
operation by disconnecting |
at people, especially at infants or |
by yourself. |
|
the power supply cord and so on. |
the aged. |
|
|
PROHIBITION |
PROHIBITION |
|
|
|
CAUTION |
|
|
Do not use for the purpose of storage of |
Take fresh air occasionally especially |
Do not operate the switch with |
|
food, art work, precise equipment, |
when gas appliance is running at the |
wet hand. |
|
breeding, or cultivation. |
same time. |
|
|
|
STRICT |
PROHIBITION |
|
PROHIBITION |
ENFORCEMENT |
||
Do not install the unit near a fireplace |
Check good condition of the |
Do not pour water onto the unit |
|
or other heating apparatus. |
installation stand |
for cleaning |
|
|
|
||
PROHIBITION |
PROHIBITION |
PROHIBITION |
|
Do not place animals or plants in |
Do not place any objects on or |
Do not place flower vase or water |
|
the direct path of the air flow |
|||
climb on the unit. |
containers on the top of the unit. |
||
|
|||
PROHIBITION |
PROHIBITION |
PROHIBITION |
4
Parts and Functions
Indoor unit
Display board |
Outlet |
Inlet |
Air filter(inside) |
Air Purifying Filter |
UV light degerming |
(inside) |
device (inside) |
Inlet grille |
|
|
Anion generator |
Vertical flap |
(inside) |
|
|
(adjust up and down air flow. |
Power plug |
Don't adjust it manually) |
|
Horizontal louver |
|
(adjust left and right air flow) |
|
Outdoor unit
HSU-09C03/VA(ZXF) HSU-09H03/VA(ZXF) HSU-12C03/VA(ZXF) HSU-12H03/VA(ZXF)
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
1OUTLET
2INLET
3CONNECTING PIPING AND ELECTRICAL WIRING
4CHANGE-FOR-FRESH-AIR BOX
5CHANGE-FOR-FRESH-AIR TUBE
6CHANGE FOR FRESH AIR SIGNAL WIRE
7DRAIN HOSE
HSU-18C03/V(ZXF) |
5 |
HSU-18H03/V(ZXF) |
Parts and Functions
FRESH
STERILIZE
19
18 |
34 |
24 |
16 |
17 |
9.HEALTH button
Used to set healthy operation.
10. ON/OFF button
Used for unit start and stop.
11. TIMER ON display
12. FAN SPEED display
LOW |
MED |
HI |
AUTO |
13. LOCK display
2814. SWING UP/DOWN display
15.SLEEP display
16.HEALTH display 17.FRESH AIR display
18. Operation mode display
Operation mode AUTO COOL DRY HEAT FAN
33
Remote controller
Display board
1.CODE
Used to select CODE A or B with a press,A or B will be displayed on LCD.
Please select A without special explanation.
2.RESET
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
4. TIMER button
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. SLEEP button
Used to select sleep mode.
7. MODE button
AUTO COOL DRY FAN HEAT
8.HOUR button
Used to set clock and timer setting.
19.Singal sending display
20.UV light degerming function display
21.Left/right air flow display
22.TEMP display
Remote controller: to display the TEMP. setting.
23.TIMER OFF display
24.CLOCK display
25.TEMP button
Used to select your desired temperature.
26.FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
27.HEALTH AIRFLOW button
Used to set the health airflow mode.
28.SWING UP/DOWN button
Used to select up or down air sending direction.
29.SWING LEFT/RIGHT button
Used to select left/right air flow.
30.FRESH button
Use to set fresh air function.
31.SET button
Used to confirm timer and clock settings.
32.STERILIZE button
Use to set UV light degerming function.
33. LOCK
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
34.Ambient temp.display
To display the Ambient temp.
NOTE:(1) The following functions and related displays are not available: 1
(2) Cooling only unit do not have functions and displays related with heating.
6
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1.Press CLOCK button,"AM" or "PM" flashes.
2.Press or to set correct time. Each press will increase or decrease
1min. If the button is kept depressed, time will change quickly.
3.After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
FRESH
STERILIZE
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / ". request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
7