Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1.Driver |
5.Torque wrench(17mm,22mm,26mm) |
9.Nipper |
12.Reamer |
2.Hacksaw |
6.Pipe cutter |
10.Gas leakage detector or |
|
3.Hole core drill |
7.Flaring tool |
soap-and-water solution |
|
4.Spanner(17,19 and 26mm) |
8.Knife |
11.Measuring tape |
|
Drawing for the installation of indoor and outdoor units
Accessory parts
Number
No. Accessory parts of
articles
1 |
Remote controller |
1 |
|||
2 |
|
R-03 dry battery |
2 |
||
3 |
|
|
|
1 |
|
|
|
|
Mounting plate |
|
|
4 |
|
|
Drain hose |
1 |
|
|
|
|
|
||
5 |
|
|
4X50 |
6 |
|
Steel nail, cement |
|||||
|
|
||||
6 |
4X25 |
Plastic cap |
4 |
||
|
Screw |
|
|
||
|
|
|
|
||
7 |
|
|
Drain-elbow |
1 |
|
|
|
|
|||
8 |
|
|
Cover |
1 |
|
|
|
|
|
||
9 |
|
|
Cushion |
4 |
|
10 |
Pipe supporting plate |
1 |
|||
11 |
Connecting cable |
1 |
Optional parts for piping
Mark |
Parts name |
ANon-adhesive tape
BAdhesive tape
CSaddle(L.S) with screws
DConnecting electric cable for indoor and outdoor
EDrain hose
FHeating insulating material
GPiping hole cover
Arrangement of piping directions
|
Rear left |
Left |
Rear |
|
right |
|
Right |
|
Below |
Note:Cooling only units don't have Drain-elbow
more than 5cm
mo |
|
re |
|
than |
|
1 |
0cm |
m |
|
|
or |
|
|
e |
|
|
t |
|
|
h |
|
|
a |
|
|
n |
|
|
1 |
|
|
0 |
|
|
|
c |
|
|
|
m |
mo |
|
re |
|
than |
|
1 |
0cm |
Attention must be paid to the rising up of drain hose
A
C
|
|
|
|
|
cm |
|
|
|
|
10 |
|
|
|
|
an |
|
|
|
|
th |
|
|
|
|
e |
|
|
|
|
or |
|
|
|
|
|
m |
|
|
|
|
|
D
E
|
|
|
m |
|
|
0c |
|
|
n6 |
|
|
retha |
|
|
|
mo |
|
|
|
mo |
|
re |
|
th |
|
an 1 |
5cm |
|
The marks from A to G in the figure are the parts numbers.
The distance between the indoor unit and the floor should be more than 2m.
No.0010535077
|
|
280 |
|
|
256 |
|
140 |
415 |
140 |
140 |
500 |
140 |
|
|
|
|
||||
Floor fixing dimensions |
Floor fixing dimensions |
|||||
of the outdoor unit |
||||||
of the outdoor unit |
||||||
(Unit:mm) |
|
(Unit:mm) |
|
|||
HSU-07LEK113 |
|
|
|
|
||
HSU-09LEK113 |
|
HSU-18LEK113 |
HSU-24LEK113 |
|||
HSU-12LEK113 |
|
|||||
|
HSU-18HEK113 |
HSU-24HEK113 |
||||
HSU-07HEK113 |
|
|||||
|
|
|
|
|||
HSU-09HEK113 |
|
|
|
|
||
HSU-12HEK113 |
|
|
|
|
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with equivalent insulation material.
|
|
For 07K 09K |
For 12K 18K |
For 24K |
|
|
|
|
|
Liquid pipe ( |
) |
6.35mm(1/4") |
6.35mm(1/4") |
9.52mm(3/8") |
|
|
|
|
|
Gas pipe ( |
) |
9.52mm(3/8") |
12.7mm(1/2") |
15.88mm(5/8") |
|
|
|
|
|
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2.Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3.Find the wall hole location A using a measuring tape
B= 60mm
B= 60mm |
24 K |
|
A=145mm
07K , 09 K , 12 K |
A=145mm |
30mm |
|
|
B= |
60mm |
18 K |
A=145mm |
30mm |
|
||
|
|
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
30mm
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it
off with putty after installation
Indoor side |
Outdoor side |
Wall hole |
Thickness |
60mm |
of wall |
|
|
(Section of wall hole) |
G Piping hole pipe |
2