Haier HSU-12HR03-R2-DB, HSU-09HRA103-R2, HSU-09HR03-R2-DB, HSM12HRAC03-R2-DB, HSM09HRAC03-R2-DB User Manual

...
0 (0)

SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL

HSU-09HR03/R2(DB) HSU-12HR03/R2(DB) HSM09HRAC03/R2(DB) HSM12HRAC03/R2(DB) HSM18HRAC03/R2(DB)

HSU-09HRA103/R2 HSU-12HRA103/R2 HSU-18HRA103/R2

Contents

CAUTIONS

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

PARTS AND FUNCTIONS

 

 

 

 

 

2

 

 

 

OPERATION

 

 

 

 

 

 

3

 

 

 

 

 

MAINTENANCE

 

 

 

 

6

 

 

 

TROUBLE SHOOTING

 

 

7

 

Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.

0010523724

Haier HSU-12HR03-R2-DB, HSU-09HRA103-R2, HSU-09HR03-R2-DB, HSM12HRAC03-R2-DB, HSM09HRAC03-R2-DB User Manual

Parts and Functions

 

 

Indoor Unit

 

 

 

Remote controller

 

 

 

 

 

 

 

 

Inlet

Air Purifying Filter

Inlet grille

(inside)

 

Outlet

 

Anion generator

Emergency

(inside)

Switch

 

Horizontal flap

Vertical blade

(adjust up and down air flow

(adjust left and

Don't adjust it manually)

right air flow)

 

Display board

Actual indoor unit may vary from the one shown

in the manual, according to the product purchased.

Display board

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Signal receiver hole

2 COOL display

3 HEAT display

4 TEMP display

5 HEALTH display

(If the unit which you purchased has healthy function,follow it.

If not,please ignore.)

6 Dry display

7 TIMER OFF display

TIMER ON display SLEEP display

Outdoor Unit

OUTLET

CONNECTING PIPING AND ELECTRICAL WIRING

INLET

4 DRAIN HOSE

Clock set

Press CLOCK button, "AM" or "PM" flashes.

Press or to set correct time. Each press will increase or decrease 1min. If the button is kept pressed,time will

change quickly. After time setting is confirmed,press SET, "AM "and "PM" stop flashing,while clock starts working.

16

 

9. ON/OFF button

 

17

10. TIMER ON display

 

15

 

11. FAN SPEED display

 

 

 

 

14

18

 

 

 

13

 

 

 

19

LOW MED

HI

AUTO

12

12. LOCK display

 

 

 

 

20

 

11

13. SWING display

 

 

21

 

 

14. SLEEP display

 

 

22

 

 

15. HEALTH display

 

 

 

 

 

 

16. Operation mode display

 

23

 

24

 

25

 

26

 

27

 

28

2

29

30

 

1.CODE Used to select CODE A or B which will be displayed on

LCD.Please select A without special explanation. 2.LIGHT button

Control the lightening and extinguishing of the indoor

LED display board. 3. TIMER button

4. CLOCK button

5. SLEEP button

6. MODE button

7. HOUR button

8. HEALTH button

Operation mode AUTO COOL DRY FAN HEAT

Remote controller

17.Signal sending display

18.POWER/SOFT display

19.TEMP display 20.TIMER OFF display

21.CLOCK display

22.TEMP button

23.FAN button

24.SWING button

25. . HEALTH AIRFLOW button

26. FRESH button

27. SET button

28. POWER/SOFT button

29. LOCK button

If pressed, the other buttons

will be disabled.Press it once again,lock will be cancelled.

30. RESET button

When the remote controller appears abnormal,use a sharp pointed article to press

this button to reset the remote controller normal.

The following functions and related displays are not available: 1 26

LIGHT button is not available for HSU-09HRA103/R2 and HSU-12HRA103/R2.

Loading of the battery

 

 

Remove the battery cover;

2

 

1Load the batteries as illustrated.

 

 

22 R-03 batteries, resetting key

 

1

(cylinder);

3

 

3 Be sure that the loading

is in line with the" + "/"-"; 4 Load the battery,then put on the cover again.

Note:

The distance between the signal transmission head and the rece-

iver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the

room, the receiver is apt to be disturbed in receiving the signals,

so the distance to the indoor unit should be shorter.

Full display or unclear display during operation indicates the batteries have been used up.Please change batteries.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.

2

TEMP-

Operation

Base Operation

Remote controller

1. Unit start

Press ON/OFF on the remote controller, unit starts.

2.Select operation mode

Press MODE button. For each press, operation mode

changes as follows: Remote controller:

AUTO COOL DRY FAN HEAT

3.Select temp.setting

Press TEMP+ / TEMP- button

TEMP+ Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOW MED

HI

AUTO

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

Operation

Display Board

Remote

Note

Mode

 

Controller

 

 

 

 

 

 

 

 

Under the mode of auto operation, air conditioner

AUTO

 

 

 

 

 

 

will automatically select Cool or Heat operation

 

 

 

 

 

 

according to room temperature. When FAN is set

 

 

 

 

 

 

 

to AUTO, the air conditioner automatically adjusts

 

 

 

 

 

 

 

the fan speed according to room temperature.

COOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In DRY mode, when room temperature becomes

DRY

 

 

 

 

 

 

lower than temp.setting+2oC, unit will run

 

 

 

 

 

 

intermittently at LOW speed regardless of FAN

 

 

 

 

 

 

 

setting.

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In FAN operation mode , the unit will not operate in

FAN

nothing

 

 

 

 

 

COOL or HEAT mode but only in FAN mode ,

 

 

 

 

 

setting is disabled. In FAN mode, sleep operation

 

 

 

 

 

 

 

AUTO is not available in FAN mode. And temp.

 

 

 

 

 

 

 

is not available.

 

 

 

 

 

 

 

 

Emergency operation and test operation

Emergency Operation:

Pi

Use this operation only when the remote controller is defective or lost.

When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.

In this operation, the system automatically selects the operation modes,cooling or fan or heat,

according to the room. temperature.

Room

Operation

Designated

Timer

 

Air flow

 

temperature

mode

 

temperature

mode

 

 

 

 

 

 

 

ABOVE 23OC

COOLING

 

26OC

 

NO

 

AUTOMATIC

 

BELOW 23OC

HEAT

 

23OC

 

NO

 

AUTOMATIC

 

 

 

 

 

 

 

 

(Cooling only uint

 

Operation

Designated

Timer

Air flow

Room temperature

 

 

mode

temperature

mode

BELOW 23OC

 

 

FAN

 

26OC

NO

AUTOMATIC

It is not possible to operate in dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room

 

temperature is below 16oC, do not use it in the

Pi Pi

normal operation.

 

Continue to press the test operation

 

switch for more than 5 seconds . After

 

you hear the "Pi" sound twice, release

 

your finger from the switch: the cooling

 

operation starts with the air flow speed "Hi".

Air Flow Direction Adjustment

1.Status display of air flow

Vertical flap

Pos.1 Pos.2 Pos.3

Pos.4 Pos.5 Pos.6 (Auto swing)

2.Left and right air flow adjustment(manual)

Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur

at air outlet if all vertical louvers are adjusted to left or right.

It is advisable not to keep horizontal flap at downward

position for a long time in COOLor DRY mode , otherwise, condensate water might occur. Note:

When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.

3

Loading...
+ 5 hidden pages