Haier HSU-18HEK03-R2-DB, HSU-12HEK03-R2-DB, HSU-12HEG03-R2-DB, HSU-24HEG03-R2-DB, HSU-09HEK03-R2-DB User Manual

...
0 (0)

SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL

HSU-09HEG03/R2(DB)

HSU-12HEG03/R2(DB)

HSU-18HEG03/R2(DB)

HSU-24HEG03/R2(DB)

HSU-09HEK03/R2(DB)

HSU-12HEK03/R2(DB)

HSU-18HEK03/R2(DB)

HSU-24HEK03/R2(DB)

Contents

PARTS AND FUNCTIONS

 

 

 

1

 

 

OPERATION

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

MAINTENANCE

 

 

 

 

 

 

 

5

 

 

 

CAUTIONS

 

 

6

 

TROUBLE SHOOTING

 

 

 

 

 

7

 

 

 

Please read this operation manual before using the air conditioner.

Keep this operation manual for future reference.

0010538410

Haier HSU-18HEK03-R2-DB, HSU-12HEK03-R2-DB, HSU-12HEG03-R2-DB, HSU-24HEG03-R2-DB, HSU-09HEK03-R2-DB User Manual

Parts and Functions

Indoor Unit

EK1 display board

1

 

 

3

 

 

 

2

 

 

 

 

 

8

 

4

 

 

 

 

 

 

 

 

 

6

5

 

7

 

EK3 display board

1

 

 

3

 

 

 

2

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

6

 

 

7

5

8

 

1

Inlet

 

2

Inlet grille

 

 

3

Air Purifying Filter(inside)

4

Outlet

 

 

 

5

Horizontal flap

 

6

Vertical blade

 

(adjust up and down air flow.

(adjust left and right air flow)

Don't adjust it manually)

 

8

Emergency Switch

7

Display board

 

 

 

 

 

 

 

 

Display board

 

 

 

 

 

 

EK1

EK3

 

 

 

 

 

 

2

 

 

 

 

4

5

 

4

 

 

 

 

 

 

 

6

 

 

 

 

 

 

Signal receiver hole

4 TIMER ON/OFF display

 

 

TIMER ON-OFF display

 

 

ON/OFF display

 

 

SLEEP display

 

 

 

Ambient temp.display

Note to the power failure resume:

 

 

When receiving the remote control

Press the sleep button ten times in five seconds and enter function

after hearing four sounds.And press the sleep button ten times

signal,display the set temperature

within five seconds and leave this function after hearing two sounds.

and in the rest time the room

temperature is displayed and this

5 COOL\HEAT\DRY\AUTO display

 

room temperature is only for reference.

6 RUNNING display

 

 

 

Please be subject to the actual produce purchased the above picture is just from your reference

Outdoor Unit

 

4

OUTLET

CONNECTING PIPING AND ELECTRICAL WIRING

INLET

DRAIN HOSE

Please be subject to the actual produce purchased the above picture is just from your reference

 

Remote controller

 

1

6

8.Additional functions display

 

 

Supplemented

 

 

 

Operation mode QUITE SLEEP electrical

HEALTH POWER

2

 

heating

 

7

Remote controller

 

3

9. QUIET button

 

 

 

 

10. HEAT button

 

4

 

 

 

11. COOL button

 

5

8

12. AUTO button

 

9

 

13. FAN SPEED button

 

18

14. TIMER button

 

10

 

15. HEALTH button

 

 

16. LOCK button

 

11

19

 

Used to lock buttons and LCD display.

 

 

20

17. LIGHT button

 

12

 

 

Control the lightening and extinguishing

 

 

of the indoor LED display board.

 

 

21

13

 

18. POWER ON/OFF button

 

 

 

19. DRY button

14

 

22

20. TEMP button

 

23

21. SWING button

15

 

22. HOUR button

16

 

24 23. EXTRA FUNCTION button

 

 

Function: Air sending--- Healthy

17

 

25

airflow position1--- Healthy airflow

 

 

 

position 2 --- Restore the original

1. Mode display

 

flap position --- Right & left air airflow

Operation mode

AUTO COOL

DRY HEAT FAN

--- A-B yard---10 and heating symbol

Remote controller

 

 

displayed simultaneously--- Sleeping

2. Signal sending display

--- Electrical heating--- Refresh air

(reserved function) --- Power ---

3. SWING display

 

 

Fahrenheit/Celsius mode conversion

4. FAN SPEED display

24.CANCEL/CONFIRM button

 

 

 

 

 

Display

Function: Setting and cancel to the

LO MED

HI

circulated

timer and other additional functions.

AUTO

25. RESET button

5. LOCK display

 

 

When the remote controller

6. TIMER OFF display

appears abnormal, use a sharp

TIMER ON display

pointed article to press this button

7.TEMP display

 

to reset the remote

Healthy function is not available for some units.

Loading of the battery

1 Remove the battery cover;

2 Load the batteries as illustrated. 2 R-03 batteries, resetting key

(cylinder);

3 Be sure that the loading is in line with the" + "/"-";

4 Load the battery,then put on the cover again.

Note:

The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or changeover type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.

1

Operation

Base Operation

Remote controller

 

1. Unit start

Press ON/OFF on the remote controller, unit starts.

2.Select operation mode

COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode

3.Select temp.setting

Press

 

 

 

button

 

 

 

 

Every time the button is pressed, temp.setting

 

 

increase 1oC,if kept depressed, it will increase

 

 

rapidly

 

 

 

 

 

Every time the button is pressed, temp.setting

 

 

 

 

decrease 1oC,if kept depressed, it will

 

 

decrease

rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

Display circulated

LOW MED

HI

AUTO

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

Operation

Remote

Note

Mode

Controller

 

 

 

Under the mode of auto operation, air conditioner will

AUTO

 

automatically select Cool or Heat operation according to

 

room temperature. When FAN is set to AUTO the air

 

 

conditioner automatically adjusts the fan speed according

 

 

to room temperature.

COOL

 

 

DRY

 

In DRY mode, when room temperature becomes lower

 

than temp.setting+2o C, unit will run intermittently at LOW

 

 

speed regardless of FAN setting.

 

 

In HEAT mode, warm air will blow out after a short

HEAT

 

period of the time due to cold-draft prevention function.

 

When FAN is set to AUTO, the air conditioner automatically

 

 

adjusts the fan speed according to room temperature.

 

 

In FAN operation mode , the unit will not operate in COOL or

FAN

 

HEAT mode but only in FAN mode, AUTO is not available in

 

FAN mode. And temp. setting is disabled. In FAN mode,

 

 

sleep operation is not available.

Emergency operation and test operation

Emergency Operation:

Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while.

When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:

Room

Designated

Timer

Fan

Operation

emergency

operation switch

temperature

temperature

mode

speed

mode

Pi

 

 

 

 

 

Above 23oC

26oC

No

AUTO

COOL

 

Below 23oC

23oC

No

AUTO

HEAT

 

It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room temperature is below 16oC, do not use it in the

normal operation.

Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling

operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor unit will run in high speed.

test operation switch

Pi

Pi

Air Flow Direction Adjustment

1.Status display of air flow

Pos.1 Pos.2 Pos.3

Pos.4 Pos.5 Pos.6 (Auto swing)

cooling mode:from pos.1 to pos.4 and pos.6 heating mode:from pos.5 to pos.1 and pos.6

2.Left and right air flow adjustment(manual)

Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.

'

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.

It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.

Note:

When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.

2