SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-09HEG03/R2(DB)
HSU-12HEG03/R2(DB)
HSU-18HEG03/R2(DB)
HSU-24HEG03/R2(DB)
HSU-09HEK03/R2(DB)
HSU-12HEK03/R2(DB)
HSU-18HEK03/R2(DB)
HSU-24HEK03/R2(DB)
Contents
PARTS AND FUNCTIONS |
|
|
|
1 |
||||||
|
|
|||||||||
OPERATION |
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|||
MAINTENANCE |
|
|
|
|
|
|
|
5 |
||
|
|
|
||||||||
CAUTIONS |
|
|
6 |
|||||||
|
||||||||||
TROUBLE SHOOTING |
|
|
|
|
|
7 |
||||
|
|
|
●Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010538410
Parts and Functions
Indoor Unit
EK1 display board |
1 |
|
|
3 |
|
|
||
|
2 |
|
|
|
|
|
8 |
|
|
4 |
|
|
|
|
|
|
|
|
|
|
6 |
5 |
|
7 |
|
|
EK3 display board |
1 |
|
|
3 |
|
|
||
|
2 |
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
6 |
|
|
7 |
5 |
8 |
|
|
1 |
Inlet |
|
2 |
Inlet grille |
|
|
||
3 |
Air Purifying Filter(inside) |
4 |
Outlet |
|
|
|
||
5 |
Horizontal flap |
|
6 |
Vertical blade |
|
|||
(adjust up and down air flow. |
(adjust left and right air flow) |
|||||||
Don't adjust it manually) |
|
8 |
Emergency Switch |
|||||
7 |
Display board |
|
||||||
|
|
|
|
|
|
|||
|
Display board |
|
|
|
|
|
|
|
EK1 |
EK3 |
|
|
|
|
|
||
|
2 |
|
|
|
|
4 |
5 |
|
|
4 |
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|
|
Signal receiver hole |
4 TIMER ON/OFF display |
|
|
|||||
TIMER ON-OFF display |
|
|
||||||
ON/OFF display |
|
|
||||||
SLEEP display |
|
|
|
|||||
Ambient temp.display |
Note to the power failure resume: |
|
|
|||||
When receiving the remote control |
Press the sleep button ten times in five seconds and enter function |
|||||||
after hearing four sounds.And press the sleep button ten times |
||||||||
signal,display the set temperature |
||||||||
within five seconds and leave this function after hearing two sounds. |
||||||||
and in the rest time the room |
||||||||
temperature is displayed and this |
5 COOL\HEAT\DRY\AUTO display |
|
||||||
room temperature is only for reference. |
6 RUNNING display |
|
|
|
Please be subject to the actual produce purchased the above picture is just from your reference
Outdoor Unit
|
4 |
OUTLET |
CONNECTING PIPING AND ELECTRICAL WIRING |
INLET |
DRAIN HOSE |
Please be subject to the actual produce purchased the above picture is just from your reference
|
Remote controller |
|
||
1 |
6 |
8.Additional functions display |
||
|
|
Supplemented |
|
|
|
|
Operation mode QUITE SLEEP electrical |
HEALTH POWER |
|
2 |
|
heating |
|
|
7 |
Remote controller |
|
||
3 |
9. QUIET button |
|
||
|
|
|||
|
10. HEAT button |
|
||
4 |
|
|
||
|
11. COOL button |
|
||
5 |
8 |
12. AUTO button |
|
|
9 |
|
13. FAN SPEED button |
|
|
18 |
14. TIMER button |
|
||
10 |
|
15. HEALTH button |
|
|
|
16. LOCK button |
|
||
11 |
19 |
|
||
Used to lock buttons and LCD display. |
||||
|
||||
|
20 |
17. LIGHT button |
|
12 |
|
|
Control the lightening and extinguishing |
|
|
|
of the indoor LED display board. |
||
|
|
21 |
||
13 |
|
18. POWER ON/OFF button |
||
|
|
|
19. DRY button |
|
14 |
|
22 |
20. TEMP button |
|
|
23 |
21. SWING button |
||
15 |
|
22. HOUR button |
||
16 |
|
24 23. EXTRA FUNCTION button |
||
|
|
Function: Air sending--- Healthy |
||
17 |
|
25 |
airflow position1--- Healthy airflow |
|
|
|
|
position 2 --- Restore the original |
|
1. Mode display |
|
flap position --- Right & left air airflow |
||
Operation mode |
AUTO COOL |
DRY HEAT FAN |
--- A-B yard---10 and heating symbol |
|
Remote controller |
|
|
displayed simultaneously--- Sleeping |
|
2. Signal sending display |
--- Electrical heating--- Refresh air |
|||
(reserved function) --- Power --- |
||||
3. SWING display |
|
|||
|
Fahrenheit/Celsius mode conversion |
|||
4. FAN SPEED display |
24.CANCEL/CONFIRM button |
|||
|
|
|
||
|
|
Display |
Function: Setting and cancel to the |
|
LO MED |
HI |
circulated |
timer and other additional functions. |
|
AUTO |
25. RESET button |
|||
5. LOCK display |
|
|||
|
When the remote controller |
|||
6. TIMER OFF display |
appears abnormal, use a sharp |
|||
TIMER ON display |
pointed article to press this button |
|||
7.TEMP display |
|
to reset the remote |
Healthy function is not available for some units.
Loading of the battery
1 Remove the battery cover;
2 Load the batteries as illustrated. 2 R-03 batteries, resetting key
(cylinder);
3 Be sure that the loading is in line with the" + "/"-";
4 Load the battery,then put on the cover again.
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or changeover type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
1
Operation
Base Operation
Remote controller |
|
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode
3.Select temp.setting
Press |
|
|
|
button |
|
|
|
||||
|
|
Every time the button is pressed, temp.setting |
|||
|
|
increase 1oC,if kept depressed, it will increase |
|||
|
|
rapidly |
|
|
|
|
|
Every time the button is pressed, temp.setting |
|||
|
|
||||
|
|
decrease 1oC,if kept depressed, it will |
|||
|
|
decrease |
rapidly |
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
Display circulated
LOW MED |
HI |
AUTO |
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation |
Remote |
Note |
|
Mode |
Controller |
||
|
|||
|
|
Under the mode of auto operation, air conditioner will |
|
AUTO |
|
automatically select Cool or Heat operation according to |
|
|
room temperature. When FAN is set to AUTO the air |
||
|
|
conditioner automatically adjusts the fan speed according |
|
|
|
to room temperature. |
|
COOL |
|
|
|
DRY |
|
In DRY mode, when room temperature becomes lower |
|
|
than temp.setting+2o C, unit will run intermittently at LOW |
||
|
|
speed regardless of FAN setting. |
|
|
|
In HEAT mode, warm air will blow out after a short |
|
HEAT |
|
period of the time due to cold-draft prevention function. |
|
|
When FAN is set to AUTO, the air conditioner automatically |
||
|
|
adjusts the fan speed according to room temperature. |
|
|
|
In FAN operation mode , the unit will not operate in COOL or |
|
FAN |
|
HEAT mode but only in FAN mode, AUTO is not available in |
|
|
FAN mode. And temp. setting is disabled. In FAN mode, |
||
|
|
sleep operation is not available. |
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while.
When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room |
Designated |
Timer |
Fan |
Operation |
emergency |
operation switch |
|||||
temperature |
temperature |
mode |
speed |
mode |
Pi |
|
|
|
|
|
|
Above 23oC |
26oC |
No |
AUTO |
COOL |
|
Below 23oC |
23oC |
No |
AUTO |
HEAT |
|
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16oC, do not use it in the
normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor unit will run in high speed.
test operation switch
Pi
Pi
Air Flow Direction Adjustment
1.Status display of air flow
Pos.1 Pos.2 Pos.3
Pos.4 Pos.5 Pos.6 (Auto swing)
cooling mode:from pos.1 to pos.4 and pos.6 heating mode:from pos.5 to pos.1 and pos.6
2.Left and right air flow adjustment(manual)
Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.
'
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
2