Haier HSU-18HEA03, HSU-05LEA03, HSU-09LEA03, HSU-12LEA03, HSU-07HEA03 Manual

...
0 (0)

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-05LEA03

HSU-07LEA03

HSU-09LEA03

HSU-09LEA03G

HSU-09LEA03U

HSU-12LEA03

HSU-12HEA03

HSU-12LEA03G

HSU-12LEA03U

HSU-18LEA03

HSU-18HEA03

HSU-18LEA03G

HSU-18LEA03U

HSU-22LEA03

HSU-22HEA03

HSU-22LEA03G

HSU-22LEA03U

HSU-24LEA03

Please read this operation manual before using the air conditioner.

0010517097

Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum:D.B/W.B

32oC/23oC

Cooling

Minimum:D.B/W.B

18oC/14oC

Outdoor

Maximum:D.B/W.B

43oC/26oC

 

 

Minimum:D.B

18oC

 

Indoor

Maximum:D.B

27oC

 

Heating

Minimum: D.B

15oC

Outdoor

Maximum:D.B/W.B

27oC/18oC

 

 

 

Minimum:D.B

-15oC

2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the applience.

9.Please employ the proper power plug, which fit into the power supply cord.

10 .The power plug and connecting cable must have acquired the local attestation.

11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.

Haier HSU-18HEA03, HSU-05LEA03, HSU-09LEA03, HSU-12LEA03, HSU-07HEA03 Manual

Cautions

 

WARNING

 

When abnormality such as burnt-small found,

Use an exclusive power source with a

immediately stop the operation button and

circuit breaker

 

contact sales shop.

 

 

 

OFF

STRICT

 

 

ENFORCEMENT

 

 

Connect power supply cord

Use the proper voltage

Do not use power supply cord

to the outlet completely

 

 

extended or connected in halfway

 

 

 

STRICT

 

STRICT

PROHIBITION

ENFORCEMENT

 

ENFORCEMENT

 

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

 

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

 

PROHIBITION

 

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of storage of

Take fresh air occasionally especially

Do not operate the switch with

food, art work, precise equipment,

when gas appliance is running at the

wet hand.

breeding, or cultivation.

same time.

 

 

 

 

STRICT

PROHIBITION

PROHIBITION

 

ENFORCEMENT

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand

 

for cleaning

PROHIBITION

 

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow

climb on the unit.

 

containers on the top of the unit.

PROHIBITION

 

PROHIBITION

PROHIBITION

3

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

CAUTION

Connect the earth

Do not install in the

Do not get the unit

Check proper

cable.

place where there is

exposed to vapor

installation of the

 

any possibility of

or oil steam.

drainage securely

 

inflammable gas

 

 

 

leakage around the

 

 

 

unit.

 

 

earthing

 

 

 

 

 

 

STRICT

 

PROHIBITION

PROHIBITION

ENFORCEMENT

4

Parts and Functions

Indoor Unit

Display board

Outlet

Inlet

Air filter(inside)

Air Purifying Filter

 

(inside)

Power plug

Inlet grille

 

Horizontal flap

Anion generator

(adjust up and down air flow.

(inside)

Don't adjust it manually)

Vertical blade

 

 

(adjust left and right air flow)

Actual inlet grille may vary from the one shown in the manual according to the product purchased

For 22k unit, the power plug is on the outdoor unit

Outdoor Unit

HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-09LEA03G HSU-09LEA03U

OUTLET

INLET

HSU-12HEA03 HSU-12LEA03

HSU-12LEA03G HSU-12LEA03U HSU-18LEA03

HSU-18HEA03 HSU-18LEA03G

HSU-18LEA03U

HSU-22LEA03 HSU-22HEA03 HSU-22LEA03G HSU-22LEA03U HSU-24LEA03

CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE

Parts and Functions

 

Remote controller

 

Display board

1

 

 

 

6

 

 

 

 

2

 

 

 

7

U

ON

OFF

8

A

 

3

T

o AM

 

9

O

C PM

 

4

 

 

 

10

 

 

 

 

5

ON/OFF

TEMP

 

11

 

 

 

12

 

 

 

19

 

MODE

SET

 

 

13

20

 

FAN

TIMER

14

21

15

CLOCK

SWING

16

22

SLEEP HEALTH

17

LOCK

24

RESET

18

23

25

1

1

26

4

7.SIGNAL SENDING display

8.TIMER OFF display

9.TIMER ON display

10.CLOCK display

11.TEMP display

12.POWER ON/OFF

Used for unit start and stop.

13.MODE

Used to select AUTO run, COOL,DRY FAN operation

14.FAN

18 9 5

HEAT and

Used to select fan speed LO, MED, HI, AUTO

15.HOUR

Used to set clock and timer setting.

16.SWING

Used to set auto fan direction.

17.SLEEP

Used to select sleep mode.

18.LOCK

Used to lock buttons and LCD display.

19.TEMP.

Used to select your desired temp.

20.SET

1. Operation mode display

 

Operation mode AUTO COOL

DRY HEAT FAN

 

Remote controller

 

 

Display board

 

2. SWING display

 

3.

FAN SPEED display

LO MED HI

 

AUTO

4. HEALTH display

 

5.

SLEEP display

 

6.

LOCK display

 

Clock set

Used to confirm timer and clock settings.

21.TIMER

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

22.CLOCK

Used to set correct time

23.RESET

Used to reset the controller back to normal condition.

24.HEALTH

Used to operate the healthy function.

25.Singal receiver hole

26.Ambient temp.display

When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

Press CLOCK button, "AM" or "PM" flashes.

Pressorto set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly.

After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.

NOTE: Cooling only unit do not have displays and functions related with heating.

Hints

After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.

Parts and Functions

If the unit which you purchased has not healthy function, Remote controller should like the following figure:

 

Remote controller

 

Display board

 

 

 

 

1

 

 

 

 

6

 

 

 

 

 

2

 

 

 

 

7

A

o

ON

OFF

8

3

T

AM

 

U

 

 

O

C PM

 

9

 

 

 

 

 

10

5

ON/OFF

TEMP

 

11

 

 

 

12

 

 

 

 

19

 

MODE

 

SET

 

 

 

13

20

 

FAN

TIMER

14

21

15

CLOCK

SWING

16

22

SLEEP

17

25

1

1

26

4

7.SIGNAL SENDING display

8.TIMER OFF display

9.TIMER ON display

10.CLOCK display

11.TEMP display

12.POWER ON/OFF

Used for unit start and stop.

13.MODE

Used to select AUTO run, COOL,DRY FAN operation

14.FAN

18 9 5

HEAT and

Used to select fan speed LO, MED, HI, AUTO

15.HOUR

Used to set clock and timer setting.

16.SWING

Used to set auto fan direction.

17.SLEEP

Used to select sleep mode.

18.LOCK

LOCK

RESET

18

23

1. Operation mode display

 

Operation mode AUTO COOL

DRY HEAT FAN

 

Remote controller

 

 

Display board

 

2. SWING display

 

3.

FAN SPEED display

LO MED HI

 

AUTO

4. HEALTH display

 

5.

SLEEP display

 

6.

LOCK display

 

Used to lock buttons and LCD display.

19.TEMP.

Used to select your desired temp.

20.SET

Used to confirm timer and clock settings.

21.TIMER

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

22.CLOCK

Used to set correct time

23.RESET

Used to reset the controller back to normal condition.

24.Singal receiver hole

25.Ambient temp.display

When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.

Clock set

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

Press CLOCK button, "AM" or "PM" flashes.

Pressorto set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly.

After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. NOTE: Cooling only unit do not have displays and functions related with heating.

Hints: After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.

7

Operation

Remote controller's operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit.

The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.

Don't throw the controller, prevent it from being damaged.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.

Loading of the battery

Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)

Remove the battery cover:

Slightly press " " and push down the cover.

Load the battery:

Be sure that the loading is in line with the" + "/"-" pole request as illustrated.

Put on the cover again

Confirmation indicator:

In disorderation, reload the batteries or load the new batteries after 6mins.

Note:

Use two new same-typed batteries when loading.

If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.

Hint:

Remove the batteries in case unit won't be in usage for a long period.

If there are any display after taking-out just need to press reset key.

Power failure resume(please set and apply as necessary)

If sudden power failure occurs, the unit will resume original operation when power is supplied again.

Note: When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.

8

Operation

Auto Operation

(1)Unit start

Press ON/OFF on the remote controller, unit starts.

(2)Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL DRY HEAT FAN

Then Select Auto operation

(3) Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

AUTO LO MED HI

ON/OFF TEMP

4

1

 

 

MODE

SET

2

FAN TIMER

3

SWING CLOCK

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

(4)Unit stop

Press ON/OFF button, the unit stops.

SLEEP HEALTH

LOCK RESET

Hints

Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting.

No reelecting is needed.(TIMER ON/OFF SLEEP

SWING needs reelecting)

Cautions:

Note:

On cooling only unit, heating mode is not available,

The above information is the

After replacing batteries, press ON/OFF, and display

explanation of the displayed

becomes as follows:

information therefore varies

Operation mode: AUTO, Temp. :No

with those displayed in actual

 

operation.

9

Operation

Cool Operation

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display. (Not Timer setting)

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

AUTO COOL DRY HEAT FAN

Unit will run in operation mode displayed on LCD. Stop display at your desired mode.

(3) Select temp. setting

Press TEMP button.

Every time the button is pressed, temp. setting increases 1oC Every time the button is pressed, temp. setting decreases 1oC

Unit will start running to reach the temp. setting on LCD.

ON/OFF TEMP

5

1

3

3

MODE

 

SET

2

 

 

 

FAN

 

 

TIMER

4

 

 

 

SWING

 

CLOCK

SLEEP HEALTH

(4) Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOCK RESET

AUTO

LO

MED

HI

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

(5) Unit stop

Press ON/OFF button, the unit stops.

Hints

On cooling only unit, heating mode is not available.

Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.

No reelecting is needed.(TIMER ON/OFF SLEEP SWING needs reelecting)

10

Operation

Dry Operation

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display. (Not Timer setting)

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

AUTO COOL DRY HEAT FAN

ON/OFF TEMP

5

1

3

3

MODE

 

SET

Unit will run in operation mode displayed on LCD. Stop display at your desired mode.

(3) Select temp. setting

Press TEMP button.

Every time the button is pressed, temp. setting increases 1oC Every time the button is pressed, temp. setting decreases 1oC

Unit will start running to reach the temp. setting on LCD.

2

FAN TIMER

4

SWING CLOCK

SLEEP HEALTH

(4) Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

 

AUTO

 

LO

 

MED

 

HI

 

 

 

 

 

 

 

 

 

 

LOCK RESET

COOL operation starts when room

temp. is higher than temp. setting.

Ultra-low air flow

Unit runs at the speed displayed on LCD.

Temp. setting+2oC

In DRY mode, when room temperature becomes

Temp. setting

lower than temp.setting+2oC,unit will run intermittently

 

at LOW speed regardless of FAN setting.

 

(5)Unit stop

Press ON/OFF button, the unit stops.

On reaching temp. setting, unit will run in mild DRY mode.

Hints

On cooling only unit, heating mode is not available.

Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.

No reelecting is needed.(TIMER ON/OFF SLEEP SWING needs reelecting)

11

Operation

Heat Operation

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display. (Not Timer setting)

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

AUTO COOL DRY HEAT FAN

Unit will run in operation mode displayed on LCD. Stop display at your desired mode.

(3) Select temp. setting

Press TEMP button.

Every time the button is pressed, temp. setting increases 1oC Every time the button is pressed, temp. setting decreases 1oC

Unit will start running to reach the temp. setting on LCD.

ON/OFF TEMP

5

1

3

3

MODE

 

SET

2

 

 

 

FAN

 

 

TIMER

4

 

 

 

SWING

 

CLOCK

SLEEP HEALTH

(4) Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOCK RESET

 

AUTO

 

LO

 

MED

 

HI

 

 

 

 

 

 

 

 

 

 

IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

(5) Unit stop

Press ON/OFF button, the unit stops.

Hints

Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.

12

Operation

Fan Operation

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display. (Not Timer setting)

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

AUTO COOL DRY HEAT FAN

Unit will run in operation mode displayed on LCD. Stop display at your desired mode.

ON/OFF TEMP

41

MODE SET

2

FAN TIMER

3

(3) Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

 

LO

 

MED

 

HI

 

 

 

 

 

 

 

 

Unit runs at the speed displayed on LCD.

(4) Unit stop

Press ON/OFF button, the unit stops.

SWING CLOCK

SLEEP HEALTH

LOCK RESET

Hints

In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode. AUTO is not available in FAN mode And temp .setting is disabled. In FAN mode,SLEEP operation is not available.

13

Operation

Air Flow Direction Adjustment

1.Status display of air sending

Horizontal flap

Remote controller

Pos.1

( Cool/Dry standard position)

Blank

Pos.2

( Upward swing )

 

 

 

 

 

 

 

 

Pos.3

( Downward swing )

 

 

 

 

 

 

 

 

Pos.4

( Auto swing )

 

 

 

 

 

 

 

 

 

 

 

 

2.Up and down air flow direction(Use remote controller)

ON/OFF TEMP

MODE SET

FAN TIMER

SWING CLOCK

For each press of SWING button, air flow direction on remote controller display as follows according to different operation modes:

 

 

 

SLEEP HEALTH

 

Pos.1

Pos.2

Pos.3

Pos.4

 

 

 

 

LOCK

RESET

The horizontal flap will swing according to the above positions

3.Left and right air flow adjustment(manual)

Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.

Cautions:

Do not try to adjust the flap by hand.

When adjusting the flap by hand,turn off the unit ,and use the remote controller to restart the unit.

When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.

It is advisable not to keep horizontal flap at downward position for a long time in COOL or DRY mode ,otherwise, condensate water. might occur.

Hints

As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more

helpful for a better air circulation.

4

Loading...
+ 33 hidden pages