Fluke 375 FC, 376 FC User Manual

0 (0)
Fluke 375 FC, 376 FC User Manual

374 FC/375 FC/376 FC

Clamp Meter

PN 4705494

September 2015

© 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.

Fluke Corporation

Fluke Europe B.V.

P.O. Box 9090

P.O. Box 1186

Everett, WA 98206-9090

5602 BD Eindhoven

U.S.A.

The Netherlands

11/99

 

Table of Contents

Title

Page

Introduction.................................................................................................................

1

Contact Fluke .............................................................................................................

2

Safety Information ......................................................................................................

3

Replacement Part List ................................................................................................

9

The Product................................................................................................................

10

Specifications .............................................................................................................

22

i

374 FC/375 FC/376 FC

Users Manual

ii

Introduction

The Fluke 374 FC/375 FC/376 FC (the Product) measures true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. The 375 FC and 376 FC also measure frequency and dc millivolts. The detachable iFlex (Flexible Current Probe) that is included with the 376 FC (optional with the 374 FC and 375 FC) expands the measurement range to 2500 A ac. The Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The illustrations in this manual show the 376 FC.

1

374 FC/375 FC/376 FC

Users Manual

Contact Fluke

To contact Fluke, call one of the following telephone numbers:

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)

Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-675-200

Japan: +81-3-6714-3114

Singapore: +65-6799-5566

Anywhere in the world: +1-425-446-5500

Or, visit Fluke's website at www.fluke.com.

To register your product, visit http://register.fluke.com.

To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals.

2

Clamp Meters

Safety Information

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.

Symbols used on the Product and in this manual are explained in Table 1.

XWWarning

To prevent possible electrical shock, fire, or personal injury:

Carefully read all instructions.

Read all safety information before you use the Product.

Use the Product only as specified, or the protection supplied by the Product can be compromised.

Do not use the Product around explosive gas, vapor, or in damp or wet environments.

Do not use and disable the Product if it is damaged.

Do not use the Product if it operates incorrectly.

Use only correct measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.

3

374 FC/375 FC/376 FC

Users Manual

Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.

Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.

Before each use, examine the Product. Look for cracks or missing pieces of the clamp housing or output cable insulation. Also look for loose or weakened components. Carefully examine the insulation around the jaws.

Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.

Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.

Do not measure current while the test leads are in the input jacks.

Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.

De-energize the circuit or wear personal protective equipment in compliance with local requirements before you apply or remove the Flexible Current Probe.

Measure a known voltage first to make sure that the Product operates correctly.

Limit operation to the specified measurement category, voltage, or amperage ratings.

The battery door must be closed and locked before you operate the Product.

4

Clamp Meters

Safety Information

Connect the common test lead before the live test lead and remove the live test lead before the common test lead.

Remove all probes, test leads, and accessories before the battery door is opened.

Keep fingers behind the finger guards on the probes.

Hold the Product behind the tactile barrier.

Replace the batteries when the low battery indicator shows to prevent incorrect measurements.

Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.

Disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction.

Remove the input signals before you clean the Product.

Use only specified replacement parts.

When batteries are changed, ensure that the calibration seal in the battery compartment is not damaged. If damaged, the Product may not be safe to use. Return the Product to Fluke for replacement of the seal.

Do not use in CAT III or CAT IV environments without the protective cap of test probe, The protective cap decreases the expose probe metal < 4mm. This decreases the possibility of arc flash from short circuits.

Do not place magnet inside Category IV panel. Place it outside the panel instead.

5

374 FC/375 FC/376 FC

Users Manual

For safe operation and maintenance of the Product:

Repair the Product before use if the battery leaks.

Have an approved technician repair the Product.

WCaution

To avoid possible damage to the Product or to equipment under test:

Use the proper jacks, function, and range for the measurement application.

Clean the case and accessories with a damp cloth and mild detergent only. Do not use abrasives or solvents.

Note

The Measurement Category (CAT) and voltage rating of any combination of test probe, test probe accessory, current clamp accessory, and the Product is the LOWEST rating of any individual component.

6

 

 

 

 

Clamp Meters

 

 

 

 

Safety Information

 

 

Table 1. Symbols

 

 

 

 

 

 

 

Symbol

Meaning

Symbol

Meaning

 

 

 

 

 

 

 

 

 

AC (Alternating Current)

 

Earth

 

 

 

DC (Direct Current)

X

WARNING. HAZARDOUS VOLTAGE.

 

 

 

 

 

Risk of electric shock.

 

 

P

Conforms to European Union

W

WARNING. RISK OF DANGER.

 

 

 

directives.

 

 

 

 

 

Consult user documentation.

 

Battery. Low battery when shown on

 

 

 

 

 

display.

 

 

T

Double Insulated

 

Certified by TÜV SÜD Product Service.

 

 

 

 

 

 

 

 

 

Do not apply to or remove from

 

 

 

 

 

HAZARDOUS LIVE conductors.

 

Application around and removal from

 

 

-

Do not apply around or remove

,

 

 

uninsulated hazardous live conductors is

 

 

 

from uninsulated hazardous live

 

permitted.

 

 

 

conductors without taking

 

 

 

 

 

 

 

 

 

additional protective measures.

 

 

 

 

 

 

 

 

 