LPT 40
40 Watts
LPT 40 Series
Total Power |
40 - 55 Watts |
|
|
Input Voltages |
85 - 264 VAC |
|
120 - 370 VDC |
# of Outputs |
Triple |
|
|
S P E C I A L F E A T U R E S
•Universal input
•High efficiency
•Remote sense on main output
•Built-in EMI filter
•Low output ripple
•Adjustable main output
•Overvoltage protection
•Overload protection
•Enclosure kit available (see page 56 or PowerFAX Doc. no 1025)
E N V I R O N M E N T A L
Operating temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
Power Derating Curve
|
55W |
|
|
|
|
|
30 CFM Forced Air Cooling |
|
|
|
40W |
|
|
|
Output |
30W |
Natural |
27.5W |
|
Power |
|
|||
|
|
|||
|
Convection |
|
||
(Watts) |
20W |
20W |
||
Cooling |
||||
|
10W |
|
|
|
|
0W |
|
|
|
|
|
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C |
||
|
|
TA – Ambient Temperature – °C |
|
E L E C T R I C A L S P E C I F I C A T I O N S
Input
Input range ........................... |
85-264 VAC |
|
120-370 VDC |
Frequency ............................ |
47-440 Hz |
Inrush current ....................... |
<18 A peak @ 115 VAC; |
|
<36 A peak @ 230 VAC, |
|
cold start @ 25°C |
Input current ......................... |
1 A max. (RMS) @ 115 VAC |
Efficiency .............................. |
70% typical at full load (60% for LPT41) |
EMI filter ............................... |
FCC Class B conducted |
|
CISPR 22 Class B conducted |
|
EN55022 Class B conducted |
|
VDE 0878 PT3 Class B conducted |
Safety ground |
|
leakage current .................... |
<0.5 mA @ 50/60 Hz, 264 VAC input |
Output
Maximum power ................... |
40 W for convection, (LPT41, 25W); |
|
55 W with 30 CFM forced air (LPT41, 41W) |
Adjustment range ................. |
-5, +10% minimum |
Cross regulation ................... |
±2% on output 1; ±5% on outputs 2, 3 |
Hold-up time ......................... |
20 ms @ 40 W load, 115 VAC nominal line |
Overload protection .............. |
Short circuit protection on all outputs. |
|
Case overload protected @ 110-145% |
|
above peak rating |
Overvoltage protection ......... |
5.7 to 6.7 VDC on main output |
Remote sense ...................... |
Compensates for 0.5 V lead drop min. Will |
|
operate without remote sense connected. |
|
Reverse connection protected. |
S A F E T Y
VDE |
0805/EN60950 (IEC950) |
11774-3336-1241 (LC# 84936) |
UL |
UL1950 |
E132002 |
CSA |
CSA 22.2-234 Level 3 |
LR53982C |
NEMKO EN 60950/EMKO-TUE |
P94100374 |
|
|
(74-sec) 203 |
|
BABT |
EN60950/BS7002 |
PS/604782 |
CB |
Certificate and report |
1118,1122,1123,1124 |
CE |
Mark (LVD) |
|
20 USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662