EMERSON LPS61, LPS62, LPS63, LPS64, LPS65 Service Manual

...
0 (0)
EMERSON LPS61, LPS62, LPS63, LPS64, LPS65 Service Manual

Embedded Power for Business-Critical Continuity

LPS60 Series

60 Watts

Total Power:

60

-

80 Watts

Input Voltage:

85

-

264 Vac

 

120

- 300Vdc

# of Outputs:

Single

Special Features

Universal input

3" x 5" footprint

Remote sense

Built in EMI filter

Low output ripple

Adjustable output voltage

Overload protection

110 KHz switching frequency

LPX60 enclosure kit available

Safety

VDE 0805/EN60950 (IEC950) 11774-3336-1255

(LC #86665) UL UL1950

E132002

CSA CSA 22.2-234 Level 3

LR53982C

NEMKO EN 60950/EMKO-TUE

P95100123

(74-sec) 203

CB Certificate and report 1521, 1522, 1523, 1524

CE Mark (LVD)

Rev. 05.27.08

LPS60 Series

1 of 3

Electrical Specifications

Input

Input range:

85 - 264 Vac (wide range)

 

120 - 300 Vdc

Frequency:

47-440 Hz

Inrush current:

<18A peak @ 115 Vac, <36 A peak @230 Vac,

 

cold start @ 25 °C

Input current:

1.5 A max. (RMS) @ 115 Vac

Efficiency:

70% typical at full load

EMI filter:

FCC Class B conducted; CISPR22 Class B conducted; EN55022

 

Class B conducted; VDE0878PT3 Class B conducted

Safety ground leakage

<0.5 mA @ 50/60 Hz; 264 Vac input

current:

 

 

 

Output

Maximum power:

60 W for convection; 80 W with 30 CFM forced air

Adjustment range

-5, +10% minimum

Hold-up time

20 ms @ 60 W load, 115 Vac nominal line

Overload protection

Short circuit protection on all outputs.

 

 

 

Case overload protected @ 110-145% above peak rating

Overvoltage protection

5 V output; 5.7 - 6.7 Vdc. Other outputs 10% to 25%

 

 

 

above nominal output

Remote sense

Compensates for 0.5 V lead drop min. Will operate without

 

 

 

remote sense connected. Reverse connection protected.

 

 

 

 

 

 

 

 

 

 

 

 