LDO06C Series
30 Watts
Total Power: |
30 Watts |
Input Voltage: |
3-13.8 Vdc |
No. of Outputs: |
Single |
Special Features
•6 A output current rating
•Input voltage range:
3-13.8 Vdc
•Adjustable out voltage:
0.59-5.1 V
•Excellent transient response
•Minimum airflow
•Small package
•Termination voltage capability
•RoHS compliant
Safety
UL, cUL 60950-1
TÜV Product Service (EN60950) Certificate No. TBD
CB Report and Certificate to IEC60950
Embedded Power for
Business-Critical Continuity
SXX06E Rev. 08.01.06 Page 1 of 2
Rev. 03.19.08 LDO06C
1 of 4
Electrical Specifications |
|
|
|
|
RoHS |
|
|
|
|
|
|||
|
|
|
|
|||
|
|
|
|
|||
Output |
|
|
|
|
|
|
Output voltage |
See Note 5 |
|
|
|
|
0.59-5.1 V |
Output setpoint accuracy |
0.1% trim resistors |
±1.0% |
||||
Line regulation |
Low line to high line |
±0.2% |
||||
Load regulation |
Full load to min. load |
±0.5% |
||||
Min./max. load |
|
|
|
|
|
0 A/6 A |
Overshoot |
At turn-on |
|
|
|
|
0.5% max. |
Undershoot |
At turn-off |
|
|
|
|
100 mV max. |
Ripple and noise |
See Note 1 |
|
|
|
|
30 mV |
5 Hz to 20 MHz |
|
|
|
|
|
Vin=5 V, |
|
|
|
|
|
|
Vout=2.5 V |
Transient response |
See Notes 1, 2 |
130 mV max. deviation |
||||
|
|
15 µs recovery to within |
||||
|
|
|
|
|
regulation band |
|
Input |
|
|
|
|
|
|
Input voltage range |
|
|
|
|
|
3-13.8 Vdc |
Input current |
Minimum load |
|
|
|
|
50 mA |
|
Remote OFF |
|
|
|
|
5 mA |
Input current (max.) |
See Note 3 |
|
|
|
|
6 A @ lo max. |
Start-up time |
Power up |
|
|
|
|
3 ms |
|
Remote ON/OFF |
|
|
|
|
2 ms |
General |
|
|
|
|
|
|
Efficiency |
Vin=5V,Vo=2.5V,lo=6A |
92% |
||||
Switching frequency |
Fixed |
|
|
|
|
620 kHz |
Approvals and standards |
|
|
|
|
|
EN60950 |
(pending) |
|
|
|
|
|
UL/cUL6950 |
Material flammability |
|
|
|
|
|
UL94V-0 |
Weight |
|
|
|
1.899 g (0.067 oz.) |
||
MTBF |
12 V @ 40 °C, |
|
|
|
8,392,808 hours |
|
|
100% load |
|
|
|
|
|
|
Bellcore 332 |
|
|
|
|
|
Coplanarity |
Surface mount models |
|
|
|
|
150µm |
Environmental Specifications
Thermal performance |
Operating ambient |
-40 °C to +70 |
°C |
See Note 5 |
Non-operating ambient |
-40 °C to +125 |
°C |
Protection
Short-circuit |
|
|
|
|
Hiccup, non-latching |
|
Overvoltage protection |
|
|
|
Hiccup, non-latching |
||
|
|
|
|
|||
Recommended System Capacitance |
|
|
|
|||
Input |
|
See Note 6 |
|
|
0 µF |
|
Output |
|
See Note 7 |
|
|
0 µF |
|
Ordering Information |
|
|
|
|
|
|
Output |
|
|
|
Output |
Output |
|
Power |
Input |
OVP |
Output |
Current |
Current |
Efficiency |
(Max.) |
Voltage |
|
Voltage |
(Min.) |
(Max.) |
(Typical) |
30W |
3-13.8 Vdc |
N/A |
0.59-5.1 V |
0 A |
6 A |
92% |
30W |
3-13.8 Vdc |
N/A |
0.59-5.1 V |
0 A |
6 A |
92% |
30W |
3-13.8 Vdc |
N/A |
0.59-5.1 V |
0 A |
6 A |
92% |
Embedded Power for
Business-Critical Continuity
Rev. 03.19.08 LDO06C 2 of 4
Regulation |
Model |
|
Line |
Load |
Number (3,5) |
±0.2% |
±0.5% |
LDO06C-005W05-VJ |
±0.2% ±0.5% LDO06C-005W05-HJ |
||
±0.2% |
±0.5% |
LDO06C-005W05-SJ |
Part Number System with Options
Product Family |
|
Rated Output Current |
|
Performance |
|
Input Voltage |
|
Number of Pins and |
|
Output Voltage |
|
Mounting Option |
|
RoHS Compliance (9) |
|
|
|
|
|
|
|
|
|
Type of Output |
|
|
|
|
|
|
|
LDO |
|
06 |
|
C |
|
00 |
|
5W |
|
05 |
|
V |
|
J |
|
Product Family |
|
Rated Output Current |
|
Performance |
|
Input Voltage |
|
Number of Pins and |
|
Output Voltage |
|
Mounting Option |
|
RoHS Compliance |
|
LDO = C Class |
|
06 = 6 Amp |
|
C = Cost Optimized |
|
00 = 3-13.8 V |
|
Type of Output |
|
05 = 0.59-5.1 V |
|
V = Vertical |
|
J = Pb free (RoHS |
|
LDO Series |
|
|
|
|
|
|
|
5W = 5 Pins and Wide |
|
|
|
H = Horizontal |
|
6/6 compliant) |
|
|
|
|
|
|
|
|
|
Output |
|
|
|
S = Surface |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output Voltage Adjustment of the LDO06C Series
The ultra-wide output voltage trim range offers major advantages to users who select the LDO06C series. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.59-5.1 Vdc.
When the LDO06C converter leaves the factory, the output has been adjusted to the default voltage of 0.59 V.
Notes:
1.Measured as per recommended system capacitance. See Technical Reference Note.
2.di/dt = 6 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo to full lo and full lo to 0.50.
3.External input fusing is recommended.
4.Additional part numbers may be available with different output voltages.
5.Airflow dependent, 100 LFM minimum required.
6.No capacitors needed for ripple current stability.
7.No capacitors needed for stability.
8.NOTICE: The input voltage MUST be greater than the programmed output voltage. The max duty cycle is 95%. These non-isolated dc-dc modules are buck converters.