Embedded Power for Business-Critical Continuity
LPS120 Series
120 Watts
Total Power: |
80 |
- 130 Watts |
Input Voltage: |
85 |
- 264 VAC |
# of Outputs: |
Single |
Special Features
•Active power factor correction
•3" x 5" footprint
•Less than 1U high
•EN61000-3-2 compliant
•Remote sense
•Power fail and remote inhibit
•Single wire current sharing
•Adjustable main output
•Built-in Class B EMI filter
•Overvoltage protection
•Overload protection
•Thermal overload protection
•5 V Standby output and 12V Fan output
Safety
TUV: 60950
UL: 60950
CSA 60950
NEMKO: 60950
AUSTEL: 60950
CB: Certificate and report CE: Mark (LVD)
Rev. 03.24.08
LPS120 Series
1 of 3
RoHS
Electrical Specifications
Input
Input range: Frequency: Inrush current: Efficiency: EMI/RFI:
Power factor: Safety ground leakage current:
Output
85 - 264 VAC ; 127 - 300VDC
47-440 Hz
40A max., cold start @ 25°C
80% typical at full load
FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
0.99 typical
0.5mA @ 50/60 Hz, 264 VAC input
Maximum power: Adjustment range: Fan output:
Standby outputs: Hold-up time: Overload protection:
Overvoltage protection:
Remote sense:
Logical Control
Power failure:
Remote inhibit:
Remote sense:
80W for convection ; 130W with 30CFM forced air ±5% minimum on the main outputs
12V @ 500mA - 5%, +7%
5V @ 500mA ±5%
20ms @ 125W load, 120VAC input
Short circuit protection on all outputs. Case overload protected @ 120-135% above rating
20-35% above nominal output
Compensates for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected.
TTL logic signal goes high 100-500 msec after main output; it goes low at least 4 msec before loss of regulation
Requires a contact closure to disable the outputs, except 5V standby.
Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.