Emerson LK31, LK53 User Manual

0 (0)
Emerson LK31, LK53 User Manual

Installation of Glass Bowl

!WARNING

To avoid fire hazard, do not exceed three 60-watt (max.) candelabra base light bulbs.

1.Install a 60-watt (max.) candelabra base light bulb (not included) into each of the three lamp holder sockets (Figure 6).

2.Remove the bottom nut(1), the rubber washer(4) and the ring nut(3) from the light fitter(8).

3.Place the glass bowl(6) onto the threaded nipple(7). Align the fan chain with the small hole on the glass bowl. Position the rubber washer(4) and the ring nut(3) onto the threaded nipple and tighten finger tight.

4.Install the wire bound bowl holder(6) by positioning the bowl holder against the bottom of the glass bowl(6) on the threaded nipple(7). Align the small hole in the guide plate.

5.Guide the light switch chain through the bottom nut. Tighten the bottom nut onto the threaded nipple finger tight.

6.Place the chain from the fan speed switch through the small hole in the glass bowl and guide plate.

7.Attach the extension chain (supplied with the light kit) to the fan speed switch chain.

 

FAN SWITCH

 

CHAIN

(8) LIGHT FITTER

NOTE: YOUR LIGHT KIT

 

 

MAY NOT RESEMBLE

 

THE ONE PICTURED

(7) THREADED NIPPLE

HERE.

 

(6) GLASS

 

BOWL

 

(5) WIRE BOUND

 

BOWL HOLDER

(2) GUIDE PLATE

(4) RUBBER WASHER

(1) BOTTOM NUT

(3) RING NUT

 

LIGHT SWITCH

PENDANTS (2)

Figure 6 CHAIN

 

CAUTION: Never use pliers to tighten bottom nut against the bowl. A broken or damage bowl will most surely result.

8.Turn on power at the main fuse or circuit breaker box.

NOTE: It is advisable to periodically check the tightness of the bottom nut. Fan operation may loosen this nut.

LIMITED WARRANTY

What The Warranty Covers:

All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:

All components are covered by this warranty for one year from the date you purchased your light fixture. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:

Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR

REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.

To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:

This warranty also does not cover any defects, malfunctions or failures caused by:

Repairs by persons not authorized by Emerson Electric Co.,

Use of parts or accessories not authorized by Emerson Electric Co.,

Mishandling, improper installation, modifications or damage to your light fixture while in your possession, or

Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear. Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:

The original purchaser or user ceases to own the product, or

The ceiling fan is moved from its original point of installation.

This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Part No. BP7226-1

Form No. F40BP72260001

DIVISION OF EMERSON ELECTRIC CO.

Printed in China 12/06

Air Comfort Products 8100 W. Florissant • St. Louis, MO 63136

READ AND SAVE THESE INSTRUCTIONS

Wire Bound Bowl

 

Model LK31

 

SUITABLE FOR DAMP LOCATIONS

Ceiling Fan

THREE 60-WATT CANDELABRA BULBS

 

Light Fixture

 

Owner's

Low Profile Damp Light

Manual

Model LK53

 

SUITABLE FOR DAMP LOCATIONS

Net Weight: 5.3 Lbs. U® L

THREE 60-WATT CANDELABRA BULBS

!WARNING

Safety Instructions

To avoid fire, shock, and serious personal injury, follow all instructions carefully.

1.Read your Owner's Manual carefully before installing the light fixture. Retain Owner's Manual for future reference.

2.Be careful of the fan and blades when cleaning, painting, or working near the fan. Before installing or servicing the light fixture or ceiling fan, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Do not exceed the wattage indicated on fixture.

ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION

1.To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring.

2.Make certain no bare wires are exposed outside the wire connectors.

3.All wiring must conform to national and local electrical codes.

4.Follow the recommended instructions for the proper method of wiring your new light fixture. If you feel you do not have enough electrical wiring knowledge or experience, have your light fixture installed by a licensed electrician. Any electrical work not described in this manual should be performed by a licensed electrician.

WARNING: To reduce the risk of possible fire and electrical shock, install only on Emerson Model CF652, CF653, CF670, CF680, CF742 and CF2000 Ceiling Fans installed in damp locations. Permissible to use this light kit on all CF and F Series Ceiling Fans installed in indoor locations.

Form No. F40BP72260000

Part No. BP7226-1

 

U.L. Model No.: LK31/LK53