350 Watts
LPQ350 Series
Total Power: 350 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Quad
Electrical Specs
Input
Input range |
85-264 VAC; 120-300 VDC |
Frequency |
47-440 Hz |
Inrush current |
38 A max., cold start @ 25°C |
Efficiency |
75% typical at full load |
EMI filter |
FCC Class B conducted and radiated |
|
CISPR 22 Class B conducted and |
|
radiated EN55022 Class B conducted |
|
and radiated VDE 0878 PT3 Class B |
|
conducted and radiated. |
Power factor |
0.99 typical |
Safety ground leakage |
|
current |
<0.5 mA @ 50/60 Hz, 264 VAC input |
Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense on 1st and 4th output
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Adjustable floating 4th output
• 2 Supervisory output 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 135 khz switching frequency
• Cover -C
• Optional with fan cover -CF
• Optional end-mounted fan -CEF
Environmental
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
Output
Maximum power |
With cover: 350 W with 30 CFM forced |
|
air, (-C) (-CF) (-CEF) |
Adjustment range |
± 5% min. on main: 3.3-24 V on output |
|
4 |
Supervisory output |
5 V @ 500 mA regulated, 12 @ 150 mA |
|
x2 |
Hold-up time |
20 ms @ 350 W load, 115 VAC nominal |
|
line |
Overload protection |
Short circuit protection on all outputs. |
|
Case overload protected @ 110-145% |
|
above peak rating |
Overvoltage protection |
5 V output: 5.7-6.7 VDC. |
Logic Control
|
|
|
|
Power failure |
TTL logic signal goes high 50-150 msec |
||||
|
|
|
|
||||||
|
|
|
|
|
|
after 5 V output. It goes low at least 4 |
|||
|
|
|
|
|
|
||||
|
|
|
|
|
|
msec before loss of regulation |
|||
|
|
|
|
|
|
||||
|
|
|
|
Remote on/off |
Requires an external contact (N.O or |
||||
|
|
|
|
||||||
|
|
|
|
|
|
N.C) to inhibit outputs |
|||
|
|
|
|
|
|
||||
|
|
|
|
|
|
||||
|
|
|
|
DC-OK |
|
TTL logic goes high 50-150 msec after |
|||
|
|
|
|
|
|
5 V output. It goes low when there is |
|||
|
|
|
|
|
|
||||
|
|
|
|
|
|
||||
|
|
|
|
|
|
loss of regulation. |
|||
|
|
|
|
|
|
||||
|
|
|
|
Remote sense |
Compensates for 0.5 V lead drop min. |
||||
|
|
|
|
||||||
|
|
|
|
||||||
|
|
|
|
|
|
Will operate without remote sense |
|||
|
|
|
|
|
Safety |
connected. Reverse |
connection |
||
|
|
|
|
|
protected. |
|
|
||
|
|
|
|
VDE |
0805/EN60950 (IEC950) |
21310-3336-0001 |
|||
|
|
|
|
||||||
|
|
|
|
||||||
|
|
|
|
UL |
UL1950 |
|
E186249 |
||
|
|
|
|
CSA |
CSA 22.2-234 Level 5 |
LR109492C |
|||
|
|
|
|
NEMKO EN 60950/EMKO-TUE |
P97102061 (74-sec) 203 |
||||
|
|
||||||||
|
|
|
|
CB |
Certificate and report |
4048, 4049 |
|
|
|
|
|
|
|
CE |
Mark (LVD) |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
rev 12.10.03
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Technical Support: (888) 41-ASTEC or (407) 241-2752 |
|
|
||
|
|
|
|||||
128 |
|
Americas: (760) 930-4600 |
Europe (UK) 44 (1384) 842-211 |
Asia (HK) 852-2437-9662 |
|
||
|
|
|
|
|
|