Danfoss NL6FT Data sheet

5 (1)
Danfoss NL6FT Data sheet

NL6FT

Tropical Compressor

R134a

220-240V 50/60Hz

General

Code number

 

 

 

 

 

105G6628

 

 

Approvals

 

 

 

 

EN 60335-2-34, CCC

 

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

LBP

 

 

Frequency

 

Hz

 

50

 

 

 

 

60

 

Evaporating temperature

 

°C

-35 to -10

 

-35 to -10

Voltage range

 

V

187 - 254

 

198 - 254

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

60 (70)

Max. winding temperature continuous (short)

°C

125 (135)

 

125 (135)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

 

60

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

 

MBP

HBP

32°C

 

 

S

 

 

 

38°C

 

 

S

 

 

 

43°C

 

 

S

 

 

 

Remarks on application: In capillary tube systems where non-equalized pressures may

occur at compressor start, or in areas with short power supply drop-outs, a starting

 

capacitor can be used for ensuring a successful start (CSIR).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

RSIR/CSIR

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

7.4

 

 

 

 

5.9

 

Cut in Current, HST | LST

 

A

 

7.4

 

 

 

 

10.3

 

Resistance, main | start winding (25°C)

 

12.6

 

 

 

 

12.4

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

 

6.13

 

 

 

Oil quantity (type)

 

cm3

 

 

 

320

 

 

 

Maximum refrigerant charge

 

g

 

 

 

400

 

 

 

Free gas volume in compressor

 

cm3

 

 

 

2360

 

 

 

Weight without electrical equipment

kg

 

 

 

10.0

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

 

197

 

 

 

 

 

 

B

 

 

191

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

Suction connector

location/I.D. mm | angle

C

 

 

6.2 | 15°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

 

 

6.2 | 25°

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

 

 

5.0 | 35°

 

 

 

 

 

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

 

 

 

 

 

 

 

 

Oil cooler connector

location/I.D. mm | angle

F

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

 

 

Connector tolerance

I.D. mm

±0.09, on 5.0 +0.12/+0.20

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

June 2012

Manufactured by Secop for Danfoss - DEHC.ED.401.M1.02 / 520N1332

1/2

Loading...
+ 1 hidden pages