Danfoss Modbus Protocol Programming guide

4.6 (5)
Danfoss Modbus Protocol Programming guide

Technical Paper

Danfoss Modbus Protocol

01/05 / Function Code 01/05 : Write/Read

NO

 

 

Modbus Address

 

 

Name

Data Type

Description

 

 

 

 

 

 

 

 

 

 

 

D00

0 1

 

 

 

 

D01 0 D00 D01 1

 

 

 

 

D00

 

 

 

 

 

D01 0

 

 

 

 

1

 

 

 

1(0)

D02D07

 

1

 

Int

 

 

01/05

 

 

 

Relay Output Status

 

 

 

 

 

 

D00 Relay Output Status 0 Closed 1 Open (When D01 is

 

 

 

 

 

 

 

 

0, D00 is not be written; When D01 is 1, D00 can be written)

 

 

 

 

D01: Relay output priority enable 0 Automatic, 1 Manual

 

 

 

 

enable

 

 

 

 

 

D02-D07: Retain

 

 

 

 

 

 

 

02 Function Code 02 : Read Only

NO

 

 

Modbus Address

 

 

 

Name

Data Type

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

D00

0

1

 

 

 

 

D01

0

1

 

 

 

 

D02 EE

0

1

 

 

 

 

D03 0

0

1

 

 

 

 

D04 50

0

1

 

 

 

 

D05D07

 

 

 

 

1(0)

 

 

 

1

 

Int

 

 

 

 

02

D00 Internal sensor failure

0

Normal 1 Fail

 

Device Failure

 

 

 

 

D01 External sensor failure

0

Normal 1 Fail

 

 

 

 

 

 

 

 

D02 EE Failure

0

Normal 1 Fail

 

 

 

 

D03 Temp. below 0 alarm

0

Normal 1 Fail

 

 

 

 

D04 Temp. high 50 alarm

0

Normal 1 Fail

 

 

 

 

D05D07 Retain

 

 

 

 

 

 

 

 

 

VFCUA12P

© Danfoss | FHH | 2016.05 | 1

Technical Paper Danfoss Modbus Protocol

03/06 / Function Code 03/06: Read/Write

NO

 

 

 

Modbus

 

Name

Precision

Data Type

Address

Description

 

 

 

 

 

 

1

 

1

Int

1(0)

00 , 01 , 02

Thermostat status

03/06

00: Off, 01:On , 02: Frost protection(Read only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 30

 

 

 

 

 

01 02

 

 

 

2(1)

 

2

Desired room

1

Int

03/06

Temperature range 5 30

 

temperature

 

 

 

 

 

 

(Active in Temperature Control Mode 01 and 02, data

 

 

 

 

 

 

 

 

 

 

can be read and written)

 

 

 

 

 

 

 

 

 

 

 

20 45

3

 

1

Int

3(2)

( 03 )

Desired floor

03/06

Temperature range 20 45

 

 

 

 

temperature

 

 

 

(Active in Temperature Control Mode 03)

 

 

 

 

 

 

4

 

1

Int

4(3)

00 01

Child Lock ON/OFF

03/06

00: Off, 01: On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1

Int

5(4)

5 30

Desired room temp.

03/06

Temperature range 5 30

 

 

 

 

for Away Mode

 

 

 

 

 

 

 

 

 

 

6

 

1

Int

6(5)

00 01

Away Mode Enable

03/06

00: Disable, 01: Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01 02 03

 

 

 

 

7(6)

 

7

Temperature Control

1

Int

01 Room temperature. control 02 Both room and

03/06

 

Mode

 

 

floor temperature control 03 Floor temperature

 

 

 

 

 

 

 

 

 

control

 

 

 

 

 

 

 

 

 

 

 

5 35

 

 

 

 

8(7)

01 02

8

Maximum Room

1

Int

 

03/06

 

Temp. Limitation

 

 

Temperature range (5-35 ) Active in Temperature

 

 

 

 

 

 

 

 

 

Control Mode 01 and 02, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

5 35

 

 

 

 

9(8)

01 02

9

Minimum Room

1

Int

 

03/06

 

Temp. Limitation

 

 

Temperature range (5-35 ) Active in Temperature

 

 

 

 

 

 

 

 

 

Control Mode 01 and 02, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

01 02

 

 

 

 

10(9)

02

10

Floor Temp.

1

Int

01 Maximum Temperature Limitation 02 Mini-

03/06

 

Limitation Mode

 

 

mum Temperature Limitation Active in Temperature

 

 

 

 

 

 

 

 

 

Control Mode 02, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

20 45

 

 

 

11(10)

02

11

Floor Temp.

1

Int

03/06

Temperature range (20-45 ) Active in Temperature

 

Limitation Setpoint

 

 

 

 

 

 

Control Mode 02, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 45

 

 

 

12(11)

03

12

Maximum Floor

1

Int

03/06

Temperature range (20-45 ) Active in Temperature

 

Temp. Limitation

 

 

 

 

 

 

Control Mode 03, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 45

 

 

 

13(12)

03

13

Minimum Floor Temp.

1

Int

03/06

Temperature range (20-45 ) Active in Temperature

 

Limitation

 

 

 

 

 

 

Control Mode 03, data can be read and written

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14(13)

01 02

14

Frost Protection

1

Int

03/06

01: Enable, 02: Disable

 

Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

2 | © Danfoss | FHH | 2016.05

VFCUA12P