The instructions provide information about installing the VLT® Memory Module MCM 103 in VLT® Midi Drive FC 280.

The VLT® Memory Module MCM 103 is an option for FC 280 frequency converters. The module acts as a combination of both memory module and activation module.

A memory module stores firmware and parameter settings of a frequency converter. If a frequency converter malfunctions, the firmware and parameter settings on this frequency converter can be copied to new frequency converters of the same power size. Copying the settings saves the time for setting up new frequency converters for the same applications.

As an activation module, the VLT® Memory Module MCM 103 can enable locked features in the FC 280 frequency converter firmware. The data and parameter settings on a memory module are encoded files that are protected from direct viewing.

To view files in a memory module, or transfer files to a memory module, a memory module programmer is required. It is not included in this package and must be ordered separately (ordering number: 134B0792).

The memory module can be inserted and removed during operation of the frequency converter, but it is only active after a power cycle.

The personnel mounting or dismounting the memory module must be familiar with the safety instructions and measures described in the VLT® Midi Drive FC 280 Operating Guide.

Items Supplied

Description

Ordering number

 

 

VLT® Memory Module MCM 103

132B0466

Table 1.1 Ordering Numbers

 

Installation

 

1.Remove the plastic front cover of the frequency converter with a screwdriver.

1

Memory module

 

 

 

 

2

Status indicator light

 

 

 

 

3

Socket for memory module

 

 

 

Illustration 1.2 Removing the Front Cover of the Frequency

4

Memory module programmer

 

 

Converter

5

USB Type-B receptacle

 

 

 

Illustration 1.1 Memory Module and Memory Module Programmer

Danfoss A/S © 09/2017 All rights reserved.

MI07N102

Danfoss MCM 103, FC 280 Installation guide

Installation Instructions

VLT® Memory Module MCM 103

VLT® Midi Drive FC 280

2.Open the lid of the memory module container.

4.Close the lid of the memory module container.

Illustration 1.5 Lid Closed

5.

Mount the plastic front cover of the frequency

Illustration 1.3 Lid Opened

converter.

 

3. Plug the memory module in the frequency converter.

Illustration 1.6 Mounting the Front Cover of the Frequency

Converter

6.

When the frequency converter powers up, the data

Illustration 1.4 Plugging the Memory Module in the Frequency

on the frequency converter is stored into the

Converter

memory module.

2