PROFESSIONAL WEATHER CENTER
WS-1613-IT
Operation Manual
IMPORTANT:
When a battery change is required on any of the units of this set, ALL units have to be reset and user must go through initial set-up steps again.
Table of Contents
Topic |
Page |
Features |
3 |
Setting up |
6 |
Function keys |
12 |
LCD Screen |
14 |
Manual Setting |
16 |
Time alarm setting |
24 |
Weather alarm operations |
25 |
Hysteresis |
31 |
Weather forecast and weather tendency |
32 |
Wind direction and wind speed measurement |
36 |
Rainfall measurement |
37 |
Viewing history data |
37 |
Viewing the min/ max weather data |
39 |
Switch On/ Off buzzer |
46 |
Outdoor transmission 915 MHz reception |
48 |
Positioning |
49 |
Care and Maintenance |
53 |
Specification |
54 |
Warranty Info |
56 |
1
PROFESSIONAL WEATHER CENTER
Instruction Manual
Congratulations on purchasing this state-of-the-art Professional Weather Center as an example of excellent design and innovative technology. Featuring time, date, calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature and outdoor humidity, air pressure and various alarm settings for different weather conditions, this Weather Center will provide you with extensive weather information and forecast.
|
This product offers: |
INSTANT TRANSMISSION is the |
|
|
state-of-the-art new wireless |
|
|
transmission technology, exclusively |
|
|
designed and developed by LA |
|
|
CROSSE TECHNOLOGY. INSTANT |
|
|
TRANSMISSION offers you an |
|
|
immediate update (every 4 seconds!) |
|
|
of all your outdoor data measured |
|
|
from the transmitters: follow your |
|
|
climatic variations in real-time! |
|
|
|
2
FEATURES:
Weather Center
Foldout stand
Hanging hole
LCD |
Battery compartment |
|
|
|
cover |
Function keys
•Time display (manual setting)
•12/24 hour time display
•Calendar display (weekday, date, month, year)
•Time alarm function
•Weather forecasting function with 3 weather icons and weather tendency indicator
•Outdoor temperature display in ºF/°C
•Outdoor Humidity display as RH%
•MIN/MAX value of outdoor temperature and humidity display with time & date of recording
3
•Low/High outdoor temperature and humidity alarm
•Relative air pressure displayed in inHg or hPa
•Air pressure tendency indicator for the past 12 hours (bargraph format)
•LCD contrast selectable
•Low battery indicator
•Wind direction displayed in 16 steps
•Wind speed displayed in mph, km/h, or m/s, and Beaufort scale
•Wind chill displayed in °F of °C
•Max wind speed displayed with time & date of recording
•High alarm function for wind speed
•Manual reset of outdoor temperature/ humidity, pressure and wind chill data
•Total rainfall displayed in mm or inch
•Storm warning alarm
•Buzzer on/off selectable
•Storage of 200 sets of history weather data recorded in 3-hour intervals
•Wireless transmission at 915 MHz
•Transmission range up to 330 feet (100 meters)
Thermo-hygro Sensor
•Remote transmission of the outdoor temperature and humidity to the Weather Center at 915 MHz
•Weather-resistant casing
•Wall mounting case (to be mounted in a sheltered place. Avoid
direct rain and sunshine)
4
Wind Sensor
• Connected to the thermo-hygro sensor by cable
•Can be installed onto a mast or a horizontal panel
Rain Sensor
•Connected to the thermo-hygro sensor by cable
• To be mounted onto a horizontal panel
5
SETTING UP:
Wireless transmission at 915 MHz - thermohygro sensor to the Weather Center
Weather Center
Rain sensor
Wind sensor
Cable connection |
Cable connection |
between the rain sensor |
between the wind sensor |
and the thermo-hygro |
and the thermo-hygro |
sensor |
sensor |
6
Note:
The radio communication between the receiver and the transmitter in the open field reaches distances of max 330 feet, provided there are no interfering obstacles such as buildings, trees, vehicles, high voltage lines, etc.
11.Radio interferences created by PC screens, radios or TV sets can in some cases entirely cut off radio communication. Please take this into consideration when choosing standing or mounting locations.
Note :
•After batteries are installed in the transmitter, install the batteries in the weather center and the bonus receiver to receive the signal from the transmitter as soon as possible. If the weather center is powered more than 5 hours after the transmitter is powered, the weather center will never receive signal successfully from this transmitter. In this case, user will need to reinstall the batteries from the transmitter to redo set-up procedure.
•After batteries are installed, there will be synchronization between weather center and the transmitter. At this time, the signal reception icon will be blinking. When the signal is successfully received by the weather center, the icon will be switched on. (If it is not successful, the icon will not be shown in LCD) So the user can easily see whether the last reception was successful (icon on) or not (icon off). On the other hand, the short blinking of the icon shows that a reception is in progress.
9
Note:
When putting the Weather Center into operation, it is important to perform in close proximity (e.g. on a table) a complete wiring and set-up of the system. This step is important to test all components for correct function before placing and mounting them at their final destinations (See Positioning below)
1.Unwind the cables of the Rain and the Wind sensors. Connect the Rain and the Wind sensors to the Thermo-hygro sensor by plugging the connector heads of the two sensors into the appropriate sockets of the Thermo-hygro sensor.
Sockets for wind and rain sensor
2.First insert the batteries into the Thermo-hygro sensor (see “How to install and replace the batteries into the Thermo-hygro sensor“ below).
3.Then insert the batteries into the Weather Center (see “How to install and replace the batteries into the Weather Center” below). Once the batteries are installed in the Weather Center, all segments of the LCD will light up briefly and a short signal tone will be heard. It will then display the time as 12:00, the date
7
Transmitter signal reception icon
•If the signal reception is not successful on the first frequency (915MHz) for 14 seconds, the frequency is changed to 920MHz and the learning is tried another 14 seconds. If still not successful the reception is tried for 14 seconds on 910MHz. This will also be done for re-synchronization.
HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE THERMO-HYGRO SENSOR
The outdoor Thermo-hygro sensor works with 2 x “AA”, IEC LR6 1.5V batteries. To install and replace the batteries, please follow the steps below:
1.Uninstall the rain cover of the transmitter. 2.Remover the battery compartment cover.
3.Insert the batteries, observing the correct polarity (see the marking in the battery compartment).
4.Replace the battery cover and the rain cover onto the unit.
Note:
In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a random security code is assigned by the thermo-
10
as 1.1.05, the weather icons, and air pressure value. "- - -" will be shown for outdoor data.
4.Afterwards, the Weather Center will start receiving data from the transmitter. The outdoor temperature, humidity wind chill and wind speed should then be displayed on the Weather Center. If this does not happen after 30 seconds, the batteries will need to be removed from both units. You will have to start again from step 1.
5.You may then check all cables for correct connection and all components for correct function by manually turning the wind-gauge, moving the weather-vane, tilting the rain sensor to hear the impact of the internally moving seesaw, etc (See Positioning below).
6.Time and date shall be manually set (See Manual Setting below).
7.After the Weather Center has been checked for correct function with regard to the above points and found fit, the initial set up of the weather station system is finished and the mounting of the system components can take place. It must be ensured however that all components work properly together at their chosen mounting or standing locations. If e.g. there appear to be problems with the 915 MHz radio transmission, they can mostly be overcome by slightly changing the mounting locations.
8.Insert the batteries into the Bonus Receiver (see “How to install and replace the batteries into the Bonus Receiver” below).
9.Once the batteries are installed, all segments of the LCD will light up briefly. It will then display the time as 12:00 and the indoor temperature.
10.The outdoor temperature and humidity will be display after reception of data from the transmitter. If this does not happen after 1 minute, the batteries will need to be removed from all the units. You will have to start again from step 1.
Note: Please refer to the “Bonus Receiver functions and settings” below.
8
hygro sensor at start-up and this code must be received and stored by the Weather Center in the first 30 seconds of power being supplied to it.
HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE WEATHER CENTER
The Weather Center works with 3 x AA, IEC LR6, 1.5V batteries. When the batteries need to be
replaced, the low battery symbol will appear on the
LCD.
To install and replace the batteries, please follow
the steps below:
1. Remove the battery compartment cover. 2. Insert the batteries observing the correct
polarity (see the marking in the battery compartment).
3.Replace the battery cover.
HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE BONUS RECEIVER
|
Hanging hole |
LCD |
|
Display |
|
|
Battery compartment |
|
cover |
Function Keys |
Foldout stand |
11
The Bonus Receiver use 2 x AA, IEC LR6, 1.5V batteries. When the batteries need to be replaced, the low battery symbol will appear on the LCD.
To install and replace the batteries, please follow the steps below:
1. Remove the battery compartment cover.
2. Insert the batteries observing the correct polarity (see the marking in the battery compartment).
3. Replace the battery cover.
BATTERY CHANGE:
It is recommended to replace the batteries in all units every 24 months to ensure optimum accuracy of these units.
Please participate in the preservation of the environment. Return used batteries to an authorized depot.
Note:
The stored History record will not be kept after the battery change is done on the Weather Center.
IMPORTANT:
When a battery change is required on any of the units of this set, ALL units have to be reset and user must go through initial set-up steps again. See “Setting up” above.
12
FUNCTION KEYS: |
|
Weather Center: |
|
The Weather Center has 5 easy-to-use function keys. |
|
Set key |
MIN/MAX key |
+ key |
ALARM key |
HISTORY key
SET key
•Press to enter manual setting modes: LCD contrast, Manual time setting, 12/24 hour time display, Calendar setting, ºF/ºC temperature unit, Wind speed unit, Rainfall unit, Pressure unit, Relative pressure reference setting, Weather Tendency Sensitivity Value setting, Storm warning sensitivity setting and Storm Alarm On/Off setting
•In normal display mode, press and hold to switch on/off the Buzzer
•In the weather alarm setting mode, press and hold to adjust different alarm value and switch the alarm On/Off
•Press to activate the reset mode when max or min record is shown
•Stop the alarm during the time alarm or weather alarm ringing
+ key
•Press to change the calendar display to the preset alarm time, date, weekday + date or seconds in the time display
13
•Press to adjust (increase) the level of different settings
•Stop the alarm during the time alarm or weather alarm ringing
•Press to confirm to reset the max/min record
HISTORY key
•Press to display the weather data history records
•Stop the alarm during the time alarm or weather alarm ringing
•Press to exit manual setting mode and alarm setting mode
ALARM key
•Press to enter the time alarm and weather alarm setting mode
•Confirm particular alarm setting
•Press to exit the manual setting mode
•Stop the alarm during the time alarm or weather alarm ringing
•Press to exit max/ min record display mode
MIN/MAX key
•Press to display minimum and maximum records of various weather data
•Press to adjust (decrease) the level of different settings
•Stop the alarm during the time alarm or weather alarm ringing
LCD SCREEN
The LCD screen is split into 5 sections displaying the following information:
1.Time and date
2.Wind data
3.Outdoor temperature and humidity,
4.Air pressure and Rainfall data
5.Air pressure history and Weather forecast.
14
Low battery indicator |
Time alarm icon |
||||||||||||||||||||||
Time display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Calendar display |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Buzzer off indicator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wind direction display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
and wind speed in |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Beaufort scale |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wind speed Hi/ Lo |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Wind Chill in °F or ° |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
alarm icon |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wind speed in mph, |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
km/h or m/s |
||||
Outdoor temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Outdoor relative |
|||
in °F or ºC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
humidity in % |
|||||
Outdoor temp. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Outdoor Humidity |
||||||
alarm icon |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
alarm icon |
|||||||||
Relative air pressure |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total rainfall in |
||||||
display in inHg or hPa |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
inch or mm |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weather tendency |
|
Air pressure |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
indicator |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weather forecast icon |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
histogram |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Transmitter signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
reception icon |
Transmitter low battery indicator
15
MANUAL SETTING:
The following manual settings can be changed once the SET key is pressed:
•LCD contrast setting
•Manual time setting
•12/24 hour time display
•Calendar setting
•°F/ °C temperature unit setting
•Wind speed unit
•Rainfall unit setting
•Air pressure unit setting
•Relative pressure reference value setting
•Weather Tendency Sensitivity value
•Storm warning threshold value
•Alarm On/ Off setting
LCD CONTRAST SETTING
Digit flashing
The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD8" (default setting is LCD 5):
1.Press the SET key, the contrast level digit will start flashing.
2.Use the + or MIN/MAX key to adjust the level of contrast.
3.Confirm with the SET key and enter the MANUAL TIME SETTINGTX.
16
MANUAL TIME SETTING:
You then may manually set the time of the clock by following the steps below:
Minutes flashing
Hour flashing
1.The hour digit will start flashing.
2.Use the + or MIN/MAX key to set the hour.
3.Press the SET key to switch to the minutes. The minute digit will start flashing.
4.Use the + or MIN/MAX key to set the minute.
5.Confirm the time with the SET key and enter the 12/24 HOUR TIME DISPLAY SETTING.
12/24 HOUR TIME DISPLAY SETTING:
Digit flashing
The time can be set to view as 12-hour or 24-hour format. The default time display mode is 12-h. To set to 24-h time display:
1.Use the + or MIN/MAX key to toggle the value.
2.Confirm with the SET key and enter the CALENDAR SETTING.
17