Product Safety Data Sheet |
|
|
|
|
|
XEROX |
|
|
|||
PRODUCT: Document Centre 332DC/332ST/340DC/340ST |
PSDS No.: |
0823 |
|
|
|||||||
|
Document Centre 425DC/425ST |
|
|
ISSUE DATE: 07/30/99 |
|
||||||
|
Document Centre 432DC/432ST/440DC/440ST |
REV. DATE: |
06/18/01 |
|
|||||||
Section I - Product Identification |
|
|
|
|
|
|
|
|
|
||
Manufacturer's Name |
|
|
Emergency No. |
EH&S Inquiries |
|
||||||
Xerox Corporation |
|
|
|
(585) 422-2177 |
(800) 828-6571 |
|
|||||
Manufacturer's Address |
|
|
|
|
|
|
|
|
|
||
Rochester, New York 14644 |
|
|
|
|
|
|
|
|
|
||
Product Designation |
|
|
Product Identifier |
|
|
|
|
||||
Document Centre 332DC/332ST/340DC/340ST |
|
XTC-1 |
|
|
|
|
|
||||
Document Centre 425DC/425ST |
|
|
|
|
|
|
|
|
|
||
Document Centre 432DC/432ST/440DC/440ST |
|
|
|
|
|
|
|
||||
Section II - Electrical Information |
|
|
|
|
|
|
|
|
|
||
Line Voltage Line Current |
Freq. |
Branch Cir. Protection |
|
|
|||||||
|
(Volts) |
(Amps) |
(Hertz) |
|
(Amps) |
|
|
|
|
|
|
115-127 |
10 |
60 |
|
15 |
|
|
|
|
|
||
Line Cord/Plug Specification |
|
|
|
Power Consumption(Watts)* |
|
||||||
Equipped with Appliance Coupler |
|
|
|
Running: |
750 |
|
|
|
|||
Detachable Cord, Two wire + Ground |
|
|
Standby: |
200 |
|
|
|
||||
NEMA 5-20R |
|
|
|
|
Low Power: 100 |
|
|
|
|||
Agency Approval |
|
|
|
|
|
|
|
|
|
|
|
UL |
File Number E51370 |
|
|
|
|
|
|
|
|
|
|
Section III - Supplies |
Xerox Part No. |
|
Material Safety Data Sheet |
|
|||||||
|
|
|
|
||||||||
Dry Ink, CRU |
113R316, 113R317, 113R321 |
|
A-0600 |
|
|
||||||
|
|
113R322, 113R323, 113R324 |
|
|
|
|
|
|
|||
Section IV - Environmental Information |
|
|
|
|
|
|
|
|
|
||
Floor Space Requirements |
Heat Emission* |
|
Environmental Limitations |
||||||||
|
(Meters) |
|
|
|
|
|
|
|
|
Min Max |
|
W: 2.27 |
Running: |
2,550 |
|
Relative Humidity (%) |
10 |
85 |
|||||
|
D: 1.83 |
Standby: |
680 |
|
Ambient Temp. (oC) |
10 |
32 |
||||
Product Size |
|
|
|
|
Weight |
|
|
|
|
||
Centimeters |
|
|
|
|
(K Grams) |
|
|
|
|||
D: |
55.4 |
|
|
|
|
IOT & IIT |
120 |
|
|
||
W: 65.5 or 128.5 with DSS/HCF |
|
|
|
DSS |
|
|
19 |
|
|
||
H: 109.4 or 128.0 with TMB |
|
|
|
HCF |
|
|
18 |
|
|
||
|
|
|
|
|
|
TMB |
|
|
16 |
|
|
*Based on a five minute average
**MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA (Section II (2) )
www.xerox.com Reference “About Xerox