VISHAY 440L, 30LV, 30LVS, 25Y, 125L Technical data

...
4 (1)
VISHAY 440L, 30LV, 30LVS, 25Y, 125L Technical data
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS

125L

440L, 30LV, 30LVS, 25Y, 125L, 20VL Series

Vishay Cera-Mite

AC Line Rated Disc Capacitors

X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE, LINE-BY-PASS, ANTENNA COUPLING

Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specifically designed and tested for use on 125 Volt through 600 Volt AC power sources. Certified to meet demanding X & Y type worldwide safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass

filtering applications. Vishay Cera-Mite offers the most complete selection in the industry—six product families— exactly tailored to your needs.

Worldwide Safety Agency Recognition

PERFORMANCE DATA / SERIES:

440L

30LV

30LVS

 

25Y

125L

20VL

 

 

 

 

 

 

 

 

 

 

Application Voltage Range

 

 

 

 

 

 

 

 

 

 

- Underwriters Laboratories - UL1414 & UL1283

250/500

300/400

250/400

 

250/400

250

250

 

 

(Vrms 50/60 Hz) (Note 1)

 

 

 

- Canadian Standards Association - CSA 22.2 No. 1 & No. 8

 

 

 

 

 

 

 

 

 

 

Dielectric Strength

4000

2500

 

2500

 

2500

2000

1250

 

 

- European EN132400 to IEC 384-14 Second Edition

(Vrms 50/60 HZ for 1 minute)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dissipation Factor (Maximum)

 

 

2%

 

 

 

 

 

Required In AC Power Supply and Filter Applications

 

 

 

 

 

 

 

Insulation Resistance (Minimum)

 

 

1000 ΩF

 

 

 

 

 

 

 

 

 

 

 

 

Six Families Tailored To Specific Industry Requirements

Mechanical Data

Service Temperature 125°C Maximum;

Complete Range of Capacitance Values

 

 

Coating Material per UL94V0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Characteristics

Y5U

Y5U

 

Y5U

 

Y5S

Y5V

Y5V

 

 

 

See Part Number Detail for Temperature Characteristics

SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS

Series / Recognition / Voltage

440L

30LV

30LVS

25Y

125L

20VL

Underwriters Laboratories Inc.: (Note 2)

 

 

 

 

 

 

 

UL 1414 Across-The-Line

Across-The-Line

Across-The-Line

UL 1414 Antenna Coupling

Antenna-Coupling

Antenna-Coupling

UL 1414 Line-By-Pass

Line-By-Pass

Line-By-Pass

Line-By-Pass

Line-By-Pass

Line-By-Pass

UL 1414 Rated Voltage

250 VAC

250 VAC

250 VAC

250 VAC

250 VAC

Electromagnetic Interference Filters

EMI Filters

EMI Filters

EMI Filters

EMI Filters

EMI Filters

UL1283 Rated Voltage

600 VAC

250 VAC

250 VAC

250 VAC

250 VAC

Canadian Standards Association:

 

 

 

 

 

 

 

CSA 22.2 No.1 Across-The-Line

Across-The-Line

Across-The-Line

CSA 22.2 No.1 Isolation

Isolation

Isolation

Isolation

Isolation

Isolation

CSA 22.2 No. 1 Rated Voltage

250 VAC

250 VAC

250 VAC

250 VAC

125/250 VAC

CSA 22.2 No. 8 Line-to-Ground Capacitors

Line-To-Ground

Line-To-Ground

Line-To-Ground

Line-To-Ground

For Use in Certified EMI Filters

Certified EMI Filters

Certified EMI Filters

Certified EMI Filters

Certified EMI Filters

CSA 22.2 No. 8 Rated Voltage

400 VAC

400 VAC

400 VAC

250 VAC

European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:

 

 

IEC 384 -14 Second Edition Subclass Y: (Note 3)

Y1

Y2

Y2

Y2

Y4

Subclass Y Voltage (Vrms 50-60 Hz)

500 VAC

300 VAC

250 VAC

250 VAC

125 VAC

 

 

Type of Insulation Bridged

Double or

Basic or

Basic or

Basic or

Basic or

 

Reinforced

Supplementary

Supplementary

Supplementary

Supplementary

 

 

Peak Impulse Voltage Before Endurance Test

8 kV

5 kV

5 kV

5 kV

2.5 kV

IEC 384-14 Second Edition Subclass X: (Note 4)

X1

X1

X1

X1

X1

X2

 

Subclass X Voltage (Vrms 50-60 Hz)

400 VAC

400 VAC

400 VAC

400 VAC

400 VAC

400 VAC

Peak Impulse Voltage in Service

2.5 to 4.0 kV

2.5 to 4.0 kV

2.5 to 4.0 kV

2.5 to 4.0 kV

2.5 to 4.0 kV

To 2.5 kV

Application

High Pulse

High Pulse

High Pulse

High Pulse

High Pulse

Gen. Purpose

Damp Heat, Steady State Recognition

 

Code HKF - 25°C/ + 125°C/21 days

 

 

 

Note 1

Voltage Ratings: All ratings are manufacturer’s rating.

Part markings are governed by agency rules and customer requirements.

Parts are marked 250 VAC unless otherwise requested.

Note 2

UL1414 Across-The-Line, Antenna Coupling, and

Line-By-Pass Capacitors:

Across-The-Line—A capacitor connected either across a supply circuit or between one side of a supply circuit and a conductive part that may be connected to earth ground.

Antenna-Coupling—A capacitor connected from an antenna terminal to circuits within an appliance.

Line-By-Pass—A capacitor connected between one side of a supply circuit and an accessible conductive part.

Note 3

IEC 384-14 Subclass Y Capacitors:

A capacitor of a type suitable for use in situations where failure of the capacitor could lead to danger of electric shock.

Class Y capacitors are divided into subclasses based on type of insulation bridged and voltage ranges.

For definitions of basic, supplementary, double and reinforced insulation, see IEC Publication 536.

Subclass Y capacitors may be used in

applications

which

require a

Subclass

X rating.

 

 

 

Note 4

 

 

 

IEC 384-14 Subclass X Capacitors:

 

• A capacitor

of a

type suitable

for use

in situations where failure of the capacitor would not lead to danger of electric shock.

Class X capacitors are divided into subclasses according to the peak impulse test voltage superimposed on the main voltage

Note 5

AC Leakage Current:

For all Series (except 125L) - AC Leakage Current (mA) specified at 250 Vrms, 60 Hz.

For 125L Series - AC Leakage Current (mA) specified at 125 Vrms, 60Hz.

Note 6

Alternate Lead Spacings of 7.5mm and 10mm are available bulk or tape & reel.

European Required Minimum Lead Clearance (Prevents Use of Inside Crimp) .315" (8mm) on 440L Series; 0.118" (3mm) on all other series.

www.vishay.com

ceramite.support@vishay.com

Document Number: 23092

20

 

Revision 14-May-02

Loading...