PC419K
PC419K
■ Features
1.Bi-directional linear output
2.High breakdown voltage
( VBR : 120V)
3.Low collector dark current ( Id : MAX. 10nA )
4.High isolation voltage between input and output ( Viso : 3 750V rms )
■ Applications
1.Board testers
2.Programmable controllers
3.Analog switch
4.Hybrid substrates which require high density mounting
Compact Surface Mounted,
Bi-directional Linear
Output Type Photocoupler
■ Outline Dimensions |
|
( Unit : mm ) |
|||||
1.27 ± 0.25 |
6 |
5 |
4 |
0.6MAX |
Internal connection |
||
|
|
|
|
diagram |
|
||
|
|
|
|
6 |
5 |
4 |
|
|
|
|
|
|
|||
|
|
PC419 |
|
|
|
|
|
|
|
|
|
± 0.2 |
|
|
|
Anode mark |
|
|
|
4.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
3 |
|
|
|
0.4 ± 0.1 |
|
|
|
|
|
1 |
|
3 |
|
5.3 ± 0.3 |
|
|
|
|
3.6 ± 0.3 |
C0.4 |
|
|
± 0.05 |
|
± 0.2 |
|
|
|
(Imput side) |
|
||
|
|
|
|
0.2 |
|||
|
|
|
|
|
|
||
2.6 |
|
|
|
|
|
|
|
0.1 |
|
|
|
0.5 +- 0.20.4 |
|
|
|
± |
|
6˚ |
|
|
|
7.0 +- 0.70.2 |
|
0.1 |
|
|
|
|
|
||
|
1 |
Anode |
4 |
Source |
|
|
|
|
3 |
Cathode |
5 |
NC |
|
|
|
|
|
|
|
6 |
Drain |
|
|
■ Package Specifications
Model No. |
Package specifications |
|
Diameter of reel |
Tape width |
|
|
PC419K |
Taping package |
( Net : 3 000pcs. |
) |
φ 370mm |
12mm |
|
PC419KT |
Taping package |
( Net : 750pcs. |
) |
φ 178mm |
12mm |
|
PC419KZ |
Sleeve package |
( Net : 100pcs. |
) |
- |
- |
|
■ Absolute Maximun Ratings |
|
|
(Ta = 25˚C ) |
|
|
Parameter |
Symbol |
Rating |
Unit |
|
|
Forward current |
IF |
50 |
mA |
Input |
|
Reverse voltage |
V R |
6 |
V |
|
|
*1Power dissipation |
P |
70 |
mW |
|
|
Output current |
IO |
10 |
mA |
Output |
|
Breakdown voltage |
V BR |
120 |
V |
|
|
*1Power dissipation |
P O |
100 |
mW |
|
Total power dissipation |
P tot |
120 |
mW |
|
*1Isolation voltage |
V iso |
3 750 |
V rms |
||
|
Operating temperature |
T opr |
- 25 to + 100 |
˚C |
|
|
Storage temperature |
T stg |
- 40 to + 125 |
˚C |
|
*2Soldering temperature |
T sol |
260 |
˚C |
*1 AC for 1 minute, 40 to 60% RH
*2 10 seconds or less, 0.2mm or more from the root of lead.
0.2mm or more |
Soldering area
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device”.