Honeywell HY-280, HY-254 User Manual

0 (0)

Owner’s Manual

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS FAN

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

FOR US MODELS ONLY – This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (follow product marking for proper fuse rating) and check

the product. If the replacement fuse blows, a short-circuit may be present and the product should be discarded or returned to an

authorized service facility for examination and/ or repair.

1.Use this fan only as described in this manual. Other use not recommended as it may cause fire, electric shock or injury to persons.

2.This product is intended for household use ONLY and not for commercial, industrial or outdoor use.

3.To protect against electric shock, do not place fan in window, immerse unit, plug or cord in water or spray with liquids.

QUIETSET®

WHOLE ROOM TOWER FAN

HY-254 Series

HY-280 Series

4.This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is

intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does

not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.

5.Close supervision is necessary when any appliance is used by or near children.

6.Turn the fan OFF and unplug the fan from the outlet when not in use, when moving the fan from one location to another and before cleaning.

7.To disconnect the fan, first turn the unit OFF, grip the plug and pull it from the wall outlet. Never pull the plug by the cord.

8.Do not operate the fan in the presence of explosive and/or flammable fumes.

9.Do not place the fan or any parts near an open flame, cooking or other heating appliance.

10.Do not operate the fan with a damaged cord or plug or if the product malfunctions, is dropped

or damaged in any manner (see warranty).

11.Avoid contact with moving fan parts.

12.The use of attachments not recommended by the manufacturer may be hazardous.

13.Place the fan on a dry level surface.

14.Do not hang or mount fan on a wall or ceiling.

15.Do not operate if the fan housing is damaged.

The Honeywell Trademark is used by Kaz USA, Inc. under license from Honeywell International Inc.

1

Honeywell International Inc. makes no representation or warranties with respect to this product.

16.A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.

17.Do not operate any fan with a damaged cord or plug. Discard any damaged fan, return the fan to the retailer where the fan was purchased, or request a return authorization to return to Kaz USA, Inc. for examination and/or repair.

18.Do not run fan cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas and where it will not be tripped over.

WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device, other than the one supplied.

FUSED SAFETY PLUG - FOR US ONLY

Thank you for your purchase.

This fan features a fused safety plug which is designed to cut off electric current to the fan if an electrical fault occurs. Please see below for more information on how to properly use your fan and replace the safety plug fuse, if needed.

USER SERVICING INSTRUCTIONS

Grasp plug and remove from the receptacle or other outlet device. Do not unplug by pulling on cord.

If your fan loses power and you suspect that the fuse on your fan has blown, you should first remove the spare fuse holder attached to the cord plug (Fig. 1). Remove the spare fuse from the plastic spare fuse holder, and set the spare fuse aside (Fig. 2).

You can gain access to the blown fuse by sliding open the door found on the side of the plug. Slide the door outward until the blown fuse is fully visible (Fig. 3).

Carefully remove the blown fuse and snap the replacement fuse into place. Risk of fire. Replace fuse only with 2.5 Amp, 125 volt fuse (provided with product). Fully close the fuse door by sliding back into place. Discard the blown fuse. The plug should now be ready for normal use.

Risk of fire. Do not replace attached plug. Contains a safety device (fuse) that should not be removed. Discard product if the attached plug is damaged.

If you need further information on how or when to replace the fuse in the safety plug, please contact Kaz Consumer Relations Department by visiting our website at www.kaz.com or calling 1-800-477-0457.

Fig. 1

Fig. 2

Fig. 3

2

Honeywell HY-280, HY-254 User Manual

ASSEMBLY INSTRUCTIONS

A. Pedestal Assembly

Line up the left and right pedestal assembly and firmly snap together (Fig. 1).

B. Base Assembly

Align the two portions of the circular base and snap together by

gently pushing the 4 extrusions (Fig. 2, Item A) into the adjacent circles of the connecting piece (Fig. 2, Item B).

C.Securing the Pedestal to the Base

Align the 3 screw holes on bottom of pedestal with the 3 holes in the base such that the power cord holder is at the rear of the unit . (Fig. 3)

Secure the base assembly to the pedestal by inserting and tightening the 3 screws in the 3 holes located on the bottom of the base (Fig. 4).

D.Securing the Tower Fan to the Pedestal

Carefully turn the fan on its side and place on a table. Place the power cord through the center of the pedestal and base assembly.

Align the pedestal with the tower fan so that the one locking screw hole on the pedestal body is aligned with the rear of the tower fan unit. Firmly hold the base steady and rotate the pedestal assembly clockwise to lock the tower fan to the pedestal assembly (Fig. 5).

Secure the pedestal to the tower fan by inserting and tightening 1 screw in the opening located near the top rear of the pedestal assembly (Fig. 6).

E.Securing the Cord to the Base

With the fan still on its side, locate the cord holding bracket on the bottom of the base.

Gently pull any slack out of the power cord, place the power cord securely in the holding bracket and secure the power cord bracket over the power cord (Fig. 7).

Return the tower fan to its upright position.

Note: Do not operate the tower fan unless it is in its proper, upright position.

Fig. 1

Pedestal Assembly

Fig. 2

 

Extrusions

A

 

 

B

Base Assembly

 

Fig. 3

Positioning

Pole

Positioning

Hole

Fig. 4

Fig. 5

Fig. 6

Fig. 7

3

CORD MANAGEMENT

The cord management feature is located on the back side

 

 

 

Fig. 8a

 

Fig. 8b

of the fan.

 

 

 

Simply double up the excess cord length, and place the two

 

 

 

pieces of cord in the notch (Fig 8b).

 

 

 

The notch will hold the cord so that the excess length will not

 

 

 

drag on the ground.

 

 

 

 

 

 

 

ASSEMBLY INSTRUCTIONS

REMOTE CONTROL BATTERY INSTALLATION/

 

REPLACEMENT INSTRUCTIONS

 

Fig. 9

A. Remove battery door by sliding downward in direction of

 

arrow.

 

B. Insert 2 AAA batteries into the remote following the directional

 

guides in the recessed slots (Fig. 9). Batteries are included.

 

C. Replace battery door by sliding upward opposite of arrow

 

direction until door snaps in place.

 

 

NOTE: DO NOT MIX OLD AND NEW BATTERIES. DO NOT MIX ALKALINE, STANDARD (CARBON-ZINC) OR RECHARGEABLE (NICKEL-CADMIUM) BATTERIES.

SEE RECYCLERS IN YOUR AREA FOR PROPER DISPOSAL OF BATTERIES.

HYFAN-254OPERATIONSERIES FAN OPERATION

On/Off

To turn fan on, press the Power button () located on the left side of the control panel.

Speed Control

The fan will automatically start on “Sleep” speed when initially turned on. To adjust

the speed up or down, press the Fan Speed button () repeatedly to increase level.

Oscillation

To activate the Oscillation feature, press the

Oscillation button () once.

Press the Oscillation button again to turn the Oscillation feature off.

Timer

Model HY-254

®

Choose from 1, 2, 4, or 8 hour settings by performing the following function:

1 hour: Press the Timer button () once.

2 hours: Press the Timer button twice.

4 hours: Press the Timer button a third time.

8 hours: Press the Timer button a fourth time.

Press the Timer button a fifth time to turn the Timer feature off.

4

HY-254 SERIES REMOTE CONTROL OPERATION

On/Off

Press the Power button () once to turn the fan on. Press the

Power button a second time to turn the fan off.

Speed Control

The fan will automatically start on “Sleep” speed when initially turned on. To adjust the speed up or down, press the Fan Speed button () repeatedly to increase level

Oscillation

 

Fig. 10

To activate the Oscillation feature, press the Oscillation button

 

( ) once.

 

Press the Oscillation button again to turn the Oscillation

 

feature off.

 

Remote Control Storage

When it is not in use, the remote control may be stored in the recessed area located behind the controls (Fig. 10).

HY-280 SERIES FAN OPERATION

On/Off

To turn fan on, press the Power button () located on the left side of the control panel. Current room temperature will be displayed whenever fan is on.

Speed Control

The fan will automatically start on “Sleep” speed when initially turned on. To adjust

the speed up or down, press the Fan Speed button () repeatedly to increase level.

Oscillation

To activate the Oscillation feature, press the

Oscillation button () once.

Press the Oscillation button again to turn the Oscillation feature off.

Timer

Model HY-280

®

Choose from 1, 2, 4, or 8 hour settings by performing the following function:

1 hour: Press the Timer button () once.

2 hours: Press the Timer button twice.

4 hours: Press the Timer button a third time.

8 hours: Press the Timer button a fourth time.

Press the Timer button a fifth time to turn the Timer feature off.

5

HY-280 SERIES FAN OPERATION CONTINUED

Temperature

A.Press and hold the Temperature Control Button to enter temperature mode.

B.Current room temperature is displayed for 3 seconds, then display begins to flash at 1 second intervals. If temperature is not selected, unit will revert back to “speed mode” after 10 seconds.

C.Press the temperature button repeatedly to increase the temperature by one degree intervals starting from room temperature.

You will have to cycle through 90° to get back to the 60° point. (This is the minimum.)

For Canada, the temperature cycle range is 15°C to 30°C.

Model HY-280

®

D.Once the desired temperature is selected, the fan will revert back to room temperature display.

Note: The fan speed will adjust automatically to achieve the desired temperature. The fan will stop if the room temperature drops below setpoint and will turn on again if the room temperature climbs above setpoint.

If the user hits the “Power” button, this will override all functions and the unit will shut “OFF”. The temperature setting will be cleared.

If the Timer button is selected, the temperature will not be affected. The chosen temperature will remain in effect and the room temperature will continue to be displayed. Timer will function with or without Temperature Mode.

Note: If user hits the “speed” button this will also override temperature mode. If the oscillation button is selected, the Temperature Mode will not be affected.

HY-280 SERIES REMOTE CONTROL OPERATION

On/Off

Press the Power button () once to turn the fan on. Press the

Power button a second time to turn the fan off.

Speed Control

The fan will automatically start on “Sleep” speed when initially turned on. To adjust the speed up or down, press the Fan Speed button () repeatedly to increase level.

Oscillation

To activate the Oscillation feature, press the Oscillation button () once.

Press the Oscillation button again to turn the Oscillation feature off.

6

Fig. 11

HY-280 SERIES REMOTE CONTROL OPERATION CONTINUED

Temperature Mode can be accessed through the remote control.

A. Press the Temperature Mode button ( ) once and release. Display will begin to flash.

B. Press the “+” and “-” buttons to change the setpoint.

Note: Once the setpoint is selected, the fan speed will adjust automatically to achieve the desired temperature. The fan will stop if the room temperature drops below the setpoint and will restart if the room temperature climbs above the setpoint.

Remote Control Storage

When it is not in use, the remote control may be stored in the recessed area located behind the controls (Fig. 11).

USER SERVICING INSTRUCTIONS

CLEANING AND STORAGE

Ensure the fan is turned off and unplugged.

Use only a soft cloth to gently wipe the outer surfaces of the fan clean.

To clean between the grills and fan blade area, we recommend using a pipe cleaner, flexible dust wand, vacuum cleaner or compressed air to gently remove the dust.

To clean the rear grill use a soft dry cloth.

DO NOT immerse the fan in water and never allow water to drip into the motor housing.

DO NOT use gasoline, paint thinner or other chemicals to clean the fan.

For storage, you may leave the fan assembled and covered to protect it from dust. Store the fan in a cool, dry place.

CONSUMER RELATIONS

Mail questions or comments to:

Call us toll-free at: 1-800-477-0457

Kaz USA, Inc.

E-mail: consumerrelations@kaz.com

Consumer Relations Dept.

Or visit our website at: www.kaz.com

250 Turnpike Road

 

Southborough, MA 01772

 

Please be sure to specify a model number.

 

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE FAN OR PERSONAL INJURY.

7

1 YEAR LIMITED WARRANTY

You should first read all instructions before attempting to use this product.

A.This 1 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR

INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B.At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship. Defective product should

be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.

C.This warranty does not cover damage resulting from any unauthorized attempts to repair

or from any use not in accordance with the instruction manual.

D.Return defective product to Kaz, Incorporated with a brief description of the problem. Include proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number. You must prepay shipping charges. Send to:

In U.S.A.:

Kaz USA, Inc.

Attn: Returns Department

4755 Southpoint Drive

Memphis, TN 38118

USA

In Canada:

Kaz Canada, Inc.

Attn: Returns Department

510 Bronte Street South

Milton, ON L9T 2X6

Canada

Please go to www.kaz.com and register your product under the Customer Care Center and receive product information updates and new promotional offers.

8

Loading...
+ 16 hidden pages