Honeywell HRG16X, HRG8X, HRG45X, HRG4X, HRG82X User Manual

...
0 (0)

HRG Performance Series DVR

 

Getting Started Guide

1

Document 800-13894 – Rev A – 01/2013

This document describes the installation and operation procedures for the following

Performance Series Honeywell DVRs:

HRG4 4-Channel DVR (HRG4X, HRG41X, HRG45X)

HRG8 8-Channel DVR (HRG8X, HRG81X, HRG82X)

HRG16 16-Channel DVR (HRG16X, HRG161X, HRG162X, HRG164X)

This document is for system integrators, installers, and end-user operators.

For more detailed information than is contained in this guide, refer to the User Guide, located on the software CD.

Cautions and Warnings

 

 

 

 

 

CAUTION

 

THIS SYMBOL INDICATES THAT

 

 

DANGEROUS VOLTAGE

 

RISK OF ELECTRIC

 

 

 

CONSTITUTING A RISK OF

 

SHOCK

 

ELECTRIC SHOCK IS PRESENT

 

DO NOT OPEN

 

WITHIN THE UNIT.

 

 

 

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC

THIS SYMBOL INDICATES THAT

SHOCK, DO NOT REMOVE THE COVER.

IMPORTANT OPERATING AND•

NO USER-SERVICEABLE PARTS INSIDE.

MAINTENANCE INSTRUCTIONS

REFER SERVICING TO QUALIFIED SERVICE

ACCOMPANY THIS UNIT.

 

PERSONNEL.

 

 

 

 

 

 

CAUTION Use only the supplied power supply.

Compliance

Manufacturer’s Declaration of Conformance

The manufacturer declares that the equipment supplied is compliant with the essential requirements of the EMC directive 2004/108/EC and Low Voltage Directive 2006/95/EC conforming to the requirements of standards EN 55022 for emissions, EN 55024 for immunity, and EN 60950-1 for electrical equipment safety.

Document 800-13894 – Rev A – 01/2013

2 | HRG Performance Series DVR Getting Started Guide

Safety Instructions

BEFORE OPERATING OR INSTALLING THE UNIT, READ AND FOLLOW ALL

INSTRUCTIONS.

AFTER INSTALLATION, retain the safety and operating instructions for future reference

1.HEED WARNINGS - Adhere to all warnings on the unit and in the operating instructions.

2.INSTALLATION

Install in accordance with the manufacturer’s instructions.

Installation and servicing should be performed only by qualified and experienced technicians to conform to all local codes and to maintain your warranty.

Do not install the unit in an extremely hot or humid location, or in a place subject to dust or mechanical vibration. The unit is not designed to be waterproof. Exposure to rain or water may damage the unit.

Any wall or ceiling mounting of the product should follow the manufacturer’s instructions and use a mounting kit approved or recommended by the manufacturer.

3.POWER SOURCES - This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied to your facility, consult your product dealer or local power company.

4.HEAT - Situate away from items that produce heat or are heat sources such as radiators, heat registers, stoves, or other products (including amplifiers).

5.WATER AND MOISTURE - Do not use this unit near water or in an unprotected outdoor installation, or any area classified as a wet location.

6.MOUNTING SYSTEM - Use only with a mounting system recommended by the manufacturer, or sold with the product.

7.ATTACHMENTS - Do not use attachments not recommended by the product manufacturer as they may result in the risk of fire, electric shock, or injury to persons.

8.ACCESSORIES - Only use accessories specified by the manufacturer.

9.CLEANING - Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

10.SERVICING - Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

11.REPLACEMENT PARTS - When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock or other hazards.

www.honeywellvideo.com

| 3

Before you Begin Installation

Unpack everything. Ensure that the items received match those listed on the order form and packing slip. In addition to your DVR and this Getting Started Guide, the packing box should include:

an IR remote control

a USB mouse

a power adapter

a CD/DVD containing the software and the User Guide

Note Other peripheral hardware (owner supplied) will be required for your installation (for example, Honeywell cameras, a VGA monitor, and appropriate cabling). See the User Guide for more information.

Installing the DVR

When installing the DVR:

Ensure there is ample room for audio and video cables.

When installing cables, ensure that the bend radius of the cables are no less than five times than its diameter.

Connect both the alarm and RS-485 cable.

Allow at least 2 cm of space between devices if rack mounted.

Ensure the DVR is grounded.

Ensure that the environmental temperature is within the range of -10 °C to 55 °C.

Ensure that the environmental humidity is within the range of 10% to 90%.

800-13894 - A - 01/2013

4 | HRG Performance Series DVR Getting Started Guide

DVR Front Panels

4-Channel HRG

Position

Control/Indicator

Function

 

 

 

 

 

 

 

 

1

IR Receiver

 

Sensor for IR Remote Controller.

 

 

 

 

 

 

 

 

2

USB Port

 

 

Connection for a USB mouse or USB flash memory device.

 

 

 

 

 

 

 

3

Status Indicators

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

Turns green when the HRG DVR is on.

 

 

 

 

 

 

 

 

STATUS

 

 

Illuminates when the compound key switches to numeric/letter input mode.

 

 

 

 

 

 

Tx/Rx

 

 

Flickers green when the network connection is functioning normally.

 

 

 

 

 

4

SHIFT

 

 

Switches the compound keys functions from inputting the numeric/letter values to the

 

 

functional controls.

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Compound Buttons

 

 

 

 

 

 

 

 

 

 

1/MENU

 

 

Enter number “1”; Access the main menu.

 

 

 

 

 

 

 

2/ABC/F1

 

 

Enter number “2” or letters “A”, “B”, “C”; The F1 button when used in a list field will

 

 

 

select all items on the list. In PTZ Control mode, it will turn on/off PTZ light.

 

 

 

 

 

 

 

 

 

 

3/DEF/F2

 

 

Enter number “3” or letters “D”, “E”, “F”; The F2 button is used to cycle through tab

 

 

 

pages. It will also bring up the Channel and OSD Position settings.

 

 

 

 

 

 

 

 

 

4/GHI/ESC

 

Enter number “4” or letters “G”, “H”, “I”; Exit and back to the previous menu.

 

 

 

 

 

 

5/JKL/EDIT

 

Enter number “5” or letters “J”, “K”, “L”; Delete characters before cursor; Select the

 

 

check box and ON/OFF switch; Start/stop record clipping in playback.

 

 

 

 

 

 

 

 

 

 

6/MNO/PLAY

 

Enter number “6” or letters “M”, “N”, “O”; Playback, for direct access to playback

 

 

interface.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/PQRS/REC

 

Enter number “7” or letters “P”, “Q”, “R”, “S”; Manual record, for direct access to

 

 

manual record interface; manually enable/disable record.

 

 

 

 

 

 

 

 

 

 

 

8/TUV/PTZ

 

Enter number “8” or letters “T”, “U”, “V”; Access to PTZ control interface.

 

 

 

 

 

9/WXYZ/PREV

 

Enter number “9” or letters “W”, “X”, “Y”, “Z”; Multi-camera display in live view.

 

 

 

 

 

 

0/A

 

 

Enter number “0”; Switch between input methods (upper and lowercase alphabet,

 

 

 

symbols and numeric input).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Directional buttons: In menu mode, the direction buttons are used to navigate

 

 

 

 

between different fields and items and select setting parameters. In playback mode, the

 

 

 

 

Up and Down buttons are used to speed up and slow down record play, and the Left

 

 

 

 

and Right buttons are used to select the recording 30s forwards or backwards. In Live

6

Control Buttons

 

View mode, these buttons can be used to cycle through channels.

 

1

2

3

4

5

6

Enter: The Enter button is used to confirm selection in the Menu mode; or used to select check box fields and ON/OFF switch. In playback mode, it can be used to play or pause the video. In single-frame play mode, pressing the Enter button advances the video by a single frame. And in auto sequence live view mode, the buttons can be used to pause / resume auto sequence.

www.honeywellvideo.com

| 5

8-Channel/16-Channel HRG

Position

Control/Indicator

Function

 

 

 

 

 

 

 

 

1

IR Receiver

 

Sensor for IR Remote Controller.

 

 

 

 

 

 

 

2

USB Port

 

Connection for a USB mouse or USB flash memory device.

 

 

 

 

 

 

3

Status Indicators

 

 

 

 

 

 

 

 

 

 

POWER

 

Turns green when the HRG DVR is on.

 

 

 

 

 

 

 

 

 

READY

 

Turns green when the device is running normally.

 

 

 

 

 

 

 

STATUS

 

Illuminates when the compound key switches to numeric/letter input mode.

 

 

 

 

 

 

 

ALARM

 

Turns red when there is a sensor alarm occurring.

 

 

 

 

 

 

 

 

 

HDD

 

Flickers red when the HDD is reading or writing.

 

 

 

 

 

 

 

 

Tx/Rx

 

Flickers green when the network connection is functioning normally.

 

 

 

 

 

4

SHIFT

 

Switches the compound keys functions from inputting the numeric/letter values to the

 

functional controls.

 

 

 

 

 

 

 

 

 

 

 

 

5

Compound Buttons

 

 

 

 

 

 

 

 

 

 

1/MENU

 

Enter number “1”; Access the main menu.

 

 

 

 

 

 

 

2/ABC/F1

 

Enter number “2” or letters “A”, “B”, “C”; The F1 button when used in a list field will

 

 

select all items on the list. In PTZ Control mode, it will turn on/off PTZ light.

 

 

 

 

 

 

 

 

3/DEF/F2

 

Enter number “3” or letters “D”, “E”, “F”; The F2 button is used to cycle through tab

 

 

pages. It will also bring up the Channel & OSD Position settings.

 

 

 

 

 

 

 

 

 

 

4/GHI/ESC

 

Enter number “4” or letters “G”, “H”, “I”; Exit and back to the previous menu.

 

 

 

 

 

5/JKL/EDIT

 

Enter number “5” or letters “J”, “K”, “L”; Delete characters before cursor; Select the

 

 

check box and ON/OFF switch; Start/stop record clipping in playback.

 

 

 

 

 

 

 

 

 

 

6/MNO/PLAY

 

Enter number “6” or letters “M”, “N”, “O”; Playback, for direct access to playback

 

 

interface.

 

 

 

 

 

 

 

 

 

 

 

 

7/PQRS/REC

 

Enter number “7” or letters “P”, “Q”, “R”, “S”; Manual record, for direct access to

 

 

manual record interface; manually enable/disable record.

 

 

 

 

 

 

 

 

 

 

 

8/TUV/PTZ

 

Enter number “8” or letters “T”, “U”, “V”; Access to PTZ control interface.

 

 

 

 

 

9/WXYZ/PREV

Enter number “9” or letters “W”, “X”, “Y”, “Z”; Multi-camera display in live view.

 

 

 

 

 

0/A

 

Enter number “0”; Switch between input methods (upper and lowercase alphabet,

 

 

symbols and numeric input).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Directional buttons: In menu mode, the direction buttons are used to navigate

 

 

 

between different fields and items and select setting parameters. In playback mode, the

 

 

 

Up and Down buttons are used to speed up and slow down record play, and the Left

 

 

 

and Right buttons are used to select the recording 30s forwards or backwards. In Live

6

Control Buttons

View mode, these buttons can be used to cycle through channels.

 

1

2

3

4

5

6

Enter: The Enter button is used to confirm a selection in the Menu mode; or used to select check box fields and the ON/OFF switch. In playback mode, it can be used to play or pause the video. In single-frame play mode, pressing the Enter button advances the video by a single frame. And in auto sequence live view mode, the buttons can be used to pause / resume auto sequence.

800-13894 - A - 01/2013

6 | HRG Performance Series DVR Getting Started Guide

DVR Back Panels

4-Channel HRG

Position

Connection/Switch

Function

 

 

 

1

Video In

BNC connectors for analog video input.

 

 

 

2

Video Out

BNC connectors for video output

 

 

 

3

Audio In

RCA connectors for analog audio input.

 

 

 

4

Line In

RCA connector for audio input.

 

 

 

5

Audio Out

RCA connector for audio output.

 

 

 

6

LAN

Connector for LAN (Local Area Network).

 

 

 

7

VGA

DB15 connector for VGA output. Display local video output and menu.

 

 

 

8

USB

Connector for USB devices.

 

 

 

9

RS-232 Port

DB9 connector for RS232 devices.

 

 

 

 

Alarm In

Connector for alarm input.

 

 

 

10

Alarm Out

Connector for alarm output.

 

 

 

 

RS-485 Port

Connector for RS-485 devices. T+, T– pins connect to PTZ.

 

 

 

11

Power

Switch for turning On/Off the device.

 

 

 

12

12 V

12 V DC power supply.

 

 

 

13

GND

Ground (needs to be connected when DVR starts up).

 

 

 

www.honeywellvideo.com

Honeywell HRG16X, HRG8X, HRG45X, HRG4X, HRG82X User Manual

| 7

8-Channel HRG

16-Channel HRG

Position

Connection/Switch

Function

 

 

 

1

Main Video Out

BNC connectors for analog video input.

 

 

Local Video Out

BNC connectors for local video out

 

 

 

 

2

Video In

BNC connectors for analog video input.

 

 

 

3

Audio In

RCA connectors for analog audio input.

 

 

 

4

Line In

RCA connector for audio input.

 

 

 

5

Audio Out

RCA connector for audio output.

 

 

 

6

RS-232 Port

DB9 connector for RS232 devices.

 

 

 

7

VGA

DB15 connector for VGA output. Display local video output and menu.

 

 

 

8

LAN

Connector for LAN (Local Area Network).

 

 

 

9

USB

Connector for USB devices.

 

 

 

10

RS-485 Port

Connector for RS-485 devices. T+, T– pins connect to PTZ.

 

 

 

11

Alarm In

Connector for alarm input.

 

 

Alarm Out

Connector for alarm output.

 

 

 

 

12

12 V

12 V DC power supply.

 

 

 

13

Power

Switch for turning On/Off the device.

 

 

 

14

GND

Ground (needs to be connected when DVR starts up).

 

 

 

800-13894 - A - 01/2013

Loading...
+ 15 hidden pages