HONEYWELL HS10S User Manual

4 (1)
HONEYWELL HS10S User Manual

HS10S

Einbauanleitung • Installation instructions • Notice de montage • Installatiehandleiding • Istruzioni di montaggio • Instrucciones de montaje • Инструкция по монтажу

EB-HS10S Rev. B

10

 

 

5

5

16

r

1

ba

 

0

 

Anleitung zum späteren Gebrauch aufbewahren! Keep instructions for later use!

Conserver la notice pour usage ultérieur! Handleiding bewaren voor later gebruik! Conservare le istruzioni per uso successivo! Guardar estas Instrucciones para su uso futuro!

Сохранить инструкцию для последующего пользования!

 

 

4

 

2

6

0

 

8

 

 

bar

 

 

10

Hauswasserstation Domastic water station Station d'eau domestique

Station voor huishoudelijk water

Stazione di rifornimento per l'acqua domestica

Grupo de suministro de agua

Домашняя водопроводная насосная станция

MU1H-1231GE23 R0109

2

Honeywell GmbH

D

1.

Sicherheitshinweise

5.

Lieferumfang

1. Beachten Sie die Einbauanleitung.

 

Die Hauswasser-Station besteht aus:

2. Benutzen Sie das Gerät

 

Gehäuse mit Manometer einund ausgangsseitig

bestimmungsgemäß

 

Rückflussverhinderer eingangsseitig

in einwandfreiem Zustand

 

Prüfventil für Rückflussverhinderer

sicherheitsund gefahrenbewusst.

 

Feinfilter in Klarsicht-Filtertasse

3. Beachten Sie, dass das Gerät ausschließlich für den in

 

Kugelventil mit Ablaufanschluss

 

dieser Einbauanleitung genannten Verwendungsbereich

 

Federhaube mit Verstellgriff und Einstellanzeige

 

bestimmt ist. Eine andere oder darüber hinausgehende

 

Ventileinsatz einschließlich Membrane und Ventilsitz

 

Benutzung gilt als nicht bestimmungsgemäß.

 

Gewindeoder Löttüllenanschluss

4. Beachten Sie, dass alle Montage-, Inbetriebnahme,

 

Absperrventil (nicht enthalten bei HS10S-ZS)

 

Wartungsund Justagearbeiten nur durch autorisierte

 

Doppelringschlüssel für Federhaube und Filtertasse

 

Fachkräfte ausgeführt werden dürfen.

6.

Varianten

 

5. Lassen Sie Störungen, welche die Sicherheit beeinträch-

 

 

HS10S-...AA =

Gewindetülle,

 

tigen können, sofort beseitigen.

 

2.

Funktionsbeschreibung

 

 

 

 

 

 

untere/obere Durchlassweite 105/135 m

 

HS10S-...AAM =

Rotgussfiltertasse, Gewindetülle,

Die Hauswasser-Station vereinigt Rückflussverhinderer,

 

 

 

 

 

 

 

untere/obere Durchlassweite 105/135 m

rückspülbaren Feinfilter, Druckminderer und Absperrventil

 

 

 

 

 

 

 

HS10S-...ZS = Gewindetülle, ohne Absperrventile,

(nicht enthalten bei HS10S-ZS) in einem Gerät.

 

 

 

 

 

 

 

untere/obere Durchlassweite 105/135 m

Entsprechend der Anordnung wird zuerst der Rückflussver-

 

 

 

 

 

 

 

 

 

 

 

 

 

hinderer durchströmt. Dabei wird bei Durchfluss ein Ventil-

 

Anschlussgröße

 

7.

Montage

 

kegel gegen eine Federkraft in Offenstellung gedrückt.

 

Der rückspülbare Feinfilter hält eventuell im Medium vorhan-

 

7.1 Einbauhinweise

dene Schmutzpartikel zurück. Beim Rückspülen werden

 

 

Einbau in waagrechte Rohrleitung mit Filtertasse nach

diese Schmutzpartikel dann komplett ausgespült.

 

 

 

unten

 

Filter mit Double Spin Technologie verfügen über Turbinen-

 

 

 

 

 

o In dieser Einbaulage ist eine optimale Funktion gewähr-

schaufeln, die das Wasser rotieren lassen und dadurch den

 

 

 

 

leistet

 

Rotor auf dem oberen Sieb in eine Drehbewegung versetzen.

 

 

 

 

Absperrventile vorsehen

Der innenliegende Impeller spült an den Überschneidungs-

 

 

Auf gute Zugänglichkeit achten

punkten mit dem Rotor die am oberen Sieb anhaftenden

 

 

 

o Manometer gut beobachtbar

Partikel aus.

 

 

 

 

 

 

 

 

o Verschmutzungsgrad bei Klarsicht-Filtertasse gut

Der integrierte Druckminderer arbeitet nach dem Kraftver-

 

 

 

 

beobachtbar

 

gleichssystem. Das heißt, einer Membrankraft wirkt die Kraft

 

 

 

 

 

o Vereinfacht Wartung und Inspektion

einer Sollwertfeder entgegen. Der Eingangsdruck wirkt weder

 

 

 

Der Einbauort muss frostsicher sein

im öffnenden noch im schließenden Sinn. Druckschwan-

 

 

Unmittelbar nach dem Wasserzähler einbauen

kungen auf der Vorderseite beeinflussen deshalb den Hinter-

 

 

 

o Entsprechend DIN 1988, Teil 2

druck nicht.

 

 

 

 

 

 

 

7.2 Montageanleitung

3.

Technische Daten

 

 

 

 

 

Bei Löttüllen-Anschluss Tüllen nicht zusammen mit

Einbaulage

 

Waagrecht mit Filtertasse nach unten

 

 

 

 

 

 

 

 

 

der Hauswasser-Station löten. Hohe Temperaturen

Betriebstemperatur

Max. 40 °C bei Klarsicht-Filtertasse

 

 

 

 

Betriebsdruck

 

Max. 70 °C bei Rotguss-Filtertasse

 

 

 

 

zerstören funktionswichtige Innenteile!

 

Min. 1,5 bar

 

 

 

 

Zuerst die Tüllen löten, danach den beigelegten

Anschlussgröße

1/2" bis 2"

 

 

 

 

Rückflussverhinderer einstecken und erst dann die

4.

Verwendung

 

 

 

 

 

Hauswasser-Station einbauen.

Medium

Wasser

 

 

 

 

Bei Montage des Rückflussverhinderers Durch-

 

 

 

 

flussrichtung beachten.

Vordruck

Max. 16,0 bar bei Klarsicht-Filtertasse

 

 

 

 

 

 

Max. 25,0 bar bei Rotguss-Filtertasse

1.

Rohrleitung gut durchspülen

Hinterdruck

1,5 - 6,0 bar

2.

Venturi-Düse einstecken (nur 2")

Das Gerät wurde für den Einsatz im Trinkwasser entwickelt.

3.

Hauswasser-Station einbauen

Die Verwendung in Prozesswässern ist im Einzelfall zu prüfen.

 

 

o Durchflussrichtung beachten

 

 

 

 

 

 

o spannungsund biegemomentfrei einbauen

 

 

 

 

 

4.

Manometer eindichten

Honeywell GmbH

 

3

 

 

 

 

 

MU1H-1101GE23 R0109

 

 

 

 

 

 

 

 

 

 

 

D

7.3 Rückspülwasserabführung

Das Rückspülwasser muss so zum Ablaufkanal geführt werden, dass kein Rückstau entstehen kann.

Dazu gibt es 3 Möglichkeiten:

1.Direkter Anschluss:

o Übergansstück DN 50/70 sowie erforderliche Rohre und Siphon (3 Bögen 90°) in DN 70.

2.Ablauf frei in vorhandenen Bodenablauf.

3.Ablauf in offenen Behälter.

Filter-Größe

Rückspülmenge*

1/2" und 3/4"

12 Liter

1" und 1 1/4"

15 Liter

1 1/2" und 2"

18 Liter

*bei 4 bar Eingangsdruck und 3 x 3 Sekunden Rückspüldauer

8. Inbetriebnahme

8.1 Hinterdruck einstellen

Ausgangsdruck min. 1 bar unter Eingangsdruck einstellen.

1.Absperrarmatur eingangsseitig schließen

2.Ausgangsseite druckentlasten (z.B. durch Wasserzapfen)

3.Absperrarmatur ausgangsseitig schließen

4.Schlitzschraube lösen

o Schlitzschraube nicht herausdrehen

5.Druckfeder entspannen

o Verstellgriff nach links (-) bis zum Anschlag drehen

6.Absperrarmatur eingangsseitig langsam öffnen

7.Verstellgriff drehen, bis die Einstellskala den gewünschten Wert anzeigt

8.Schlitzschraube wieder festziehen

9.Absperrarmatur ausgangsseitig langsam öffnen

8.2 Rückspülen

Während des Rückspülens ist ein Eingangsdruck von mindestens 1,5 bar erforderlich. Das Rückspülintervall ist abhängig vom Verschmutzungsgrad des Wassers. Spätestens alle 2 Monate muss entsprechend DIN 1988, Teil 8 eine Rückspülung durchgeführt werden. Zur bequemen und regelmäßigen Einhaltung des Rückspülintervalls empfehlen wir

den Einbau einer Rückspülautomatik Z11S.

Auch während des Rückspülens kann gefiltertes Wasser entnommen werden.

8.2.1 Manuelles Rückspülen

Erfolgt die Rückspülwasserabführung nicht durch einen direkten Anschluss, so muss vor dem Rückspülen ein Auffanggefäß untergestellt werden.

1.Kugelhahn durch Drehen des Rückspülknopfs bis Anschlag öffnen

o Markierungsbalken muss senkrecht stehen

o das patentierte Rückspülsystem wird in Gang gesetzt

oBei Filtern mit Double Spin Technologie ist eine einfache visuelle Funktionskontrolle durch den sich drehenden roten Rotor möglich

2.Kugelhahn nach ca. 3 Sekunden wieder schließen. Vorgang drei Mal wiederholen

obei stark verschmutztem Filter können zusätzliche Wiederholungen erforderlich sein

Mit Hilfe des Memory-Ringes kann der nächste Termin für die manuelle Rückspülung vorgemerkt werden.

8.2.2 Automatisches Rückspülen mit Z11S

Die Rückspülautomatik Z11S ist als Zubehör erhältlich. Die Automatik übernimmt zuverlässig das Rückspülen des Filters in einstellbaren Zeiträumen zwischen 4 Minuten und

3 Monaten.

9. Instandhaltung

Wir empfehlen einen Wartungsvertrag mit einem Installationsunternehmen abzuschließen

Entsprechend DIN 1988, Teil 8 sind folgende Maßnahmen durchzuführen:

9.1 Inspektion

9.1.1 Druckminderer

Intervall: einmal jährlich

1.Absperrarmatur ausgangsseitig schließen

2.Hinterdruck mit Druckmessgerät bei Nulldurchfluss kontrollieren

o Steigt der Druck langsam an, ist die Armatur eventuell verschmutzt oder defekt. Führen Sie in diesem Fall eine Wartung und Reinigung durch

3.Absperrarmatur ausgangsseitig langsam öffnen

9.1.2 Filter

Intervall: alle 2 Monate

Der Filter muss regelmäßig, spätestens alle 2 Monate, durch Rückspülen gereinigt werden

Eine Nichtbeachtung kann zu Filterverstopfung führen. Druckabfall und sinkender Wasserdurchfluss sind die Folge

Die Siebe des Filters sind aus nichtrostendem Stahl. Roter Belag infolge von Rost aus den Rohrleitungen hat keinen Einfluss auf Funktion und Filterwirkung

Sichtkontrolle des Kugelventils nicht vergessen. Bei Tropfenbildung auswechseln!

MU1H-1101GE23 R0109

4

Honeywell GmbH

 

 

 

D

9.1.3 Rückflussverhinderer

Intervall: einmal jährlich

1.Absperrarmatur eingangsseitig schließen

2.Prüfventil öffnen

o Bis zur Druckentlastung wird etwas Wasser am Prüfventil ausfließen. Nach kurzer Zeit muss der Wasserausfluß aufhören. Tropft oder läuft das Wasser beständig weiter, so ist der Austausch des Rückflussverhinderers notwendig - siehe Wartung Rückflussverhinderer

3.Prüfventil wieder schließen

4.Absperrventil wieder öffnen

9.2 Wartung

9.2.1 Druckminderer

Intervall: 1-3 Jahre (abhängig von den örtlichen Bedingungen)

Durchführung durch ein Installationsunternehmen.

1.Absperrarmatur eingangsseitig schließen

2.Ausgangsseite druckentlasten (z.B. durch Wasserzapfen)

3.Absperrarmatur ausgangsseitig schließen

4.Schlitzschraube lösen

o Schlitzschraube nicht herausdrehen Vorsicht !

In der Federhaube befindet sich eine Druckfeder.

Durch Herausspringen der Druckfeder kann es zu Verletzungen kommen.

Stellen Sie sicher, dass die Druckfeder entspannt ist!

5.Druckfeder entspannen

o Verstellgriff nach links (-) bis zum Anschlag drehen o Nicht überdrehen!

6.Federhaube abschrauben

o Doppelringschlüssel ZR10K verwenden

7.Gleitring herausnehmen

8.Ventileinsatz mit Zange herausziehen

9.Filtertasse und Führungsstück abschrauben o Doppelringschlüssel ZR10K verwenden

10.Nutring herausnehmen

11.Dichtscheibe, Düsenkante und Nutring auf einwandfreien Zustand überprüfen, falls erforderlich Ventileinsatz komplett auswechseln

12.Montage in umgekehrter Reihenfolge

Membrane mit Finger eindrücken, dann Gleitring einlegen

Filtertasse handfest (ohne Werkzeug) einschrauben 13.Hinterdruck einstellen und Einstellskala justieren

9.2.2 Justierung der Einstellskala

Bei Demontage des Verstellgriffs geht die Justierung verloren. Eine Neujustierung ist mit Hilfe eines Manometers möglich.

1.Absperrarmatur eingangsseitig schließen

2.Ausgangsseite druckentlasten (z.B. durch Wasserzapfen)

3.Absperrarmatur ausgangsseitig schließen

4.Schlitzschraube lösen

o Schlitzschraube nicht herausdrehen

5.Absperrarmatur eingangsseitig langsam öffnen

6.Gewünschten Hinterdruck einstellen (z.B. 4 bar)

7.Skalenwert (z.B. 4) mit Markierung in Fenstermitte in Übereinstimmung bringen

8.Schlitzschraube wieder festziehen

9.Absperrarmatur ausgangsseitig langsam öffnen

9.2.3 Filter

Intervall: alle 2 Monate

Der Filter muss regelmäßig, spätestens alle 2 Monate, durch Rückspülen gereinigt werden

Eine Nichtbeachtung kann zu Filterverstopfung führen. Druckabfall und sinkender Wasserdurchfluss sind die Folge

Die Siebe des Filters sind aus nichtrostendem Stahl. Roter Belag infolge von Rost aus den Rohrleitungen hat keinen Einfluss auf Funktion und Filterwirkung

Sichtkontrolle des Kugelventils nicht vergessen. Bei Tropfenbildung auswechseln!

9.2.4 Rückflussverhinderer

Durchführung durch ein Installationsunternehmen.

1.Absperrarmatur eingangsseitig schließen

2.Ausgangsseite druckentlasten (z.B. durch Wasserzapfen)

3.Absperrarmatur ausgangsseitig schließen

4.Rückflussverhinderer austauschen

9.3 Reinigung

Vorsicht !

Zum Reinigen der Kunststoffteile keine lösungsmittelund/oder alkoholhaltigen Reinigungsmittel benutzen, da diese zu Wasserschäden führen können!

1.Absperrarmatur eingangsseitig schließen

2.Ausgangsseite druckentlasten (z.B. durch Wasserzapfen)

3.Absperrarmatur ausgangsseitig schließen

4.Siebtasse abschrauben

o Doppelringschlüssel ZR10K verwenden

5.Sieb herausnehmen, reinigen und wieder einstecken

6.O-Ring auf Siebtasse stecken

7.Absperrarmatur eingangsseitig langsam öffnen

8.Absperrarmatur ausgangsseitig langsam öffnen

Honeywell GmbH

5

MU1H-1101GE23 R0109

 

 

 

D

10. Entsorgung

Gehäuse aus entzinkungsbeständigem Messing

Absperrventil und Verschraubungen aus Messing

Einsteckrückflussverhinderer aus hochwertigem Kunststoff

Feinfilter aus nichtrostendem Stahl

Filtertasse aus stoßfestem, glasklarem Kunststoff oder Rotguss

Federhaube aus hochwertigem Kunststoff

Ventileinsatz aus hochwertigem Kunststoff

Membrane aus NBR, gewebeverstärkt

Dichtungen aus NBR

Die örtlichen Vorschriften zur ordnungsgemäßen

Abfallverwertung bzw. Beseitigung beachten!

11. Störungen / Fehlersuche

Störung

Ursache

Behebung

Wasseraustritt aus Federhaube

Membrane Ventileinsatz defekt

Ventileinsatz ersetzen

 

 

 

Kein oder zu wenig Wasserdruck

Absperrarmaturen vor oder hinter Haus-

Absperrarmaturen ganz öffnen

 

wasserstation nicht ganz geöffnet

 

 

 

 

 

Druckminderer nicht auf gewünschten

Hinterdruck einstellen

 

Hinterdruck eingestellt

 

 

 

 

 

Filtersieb verschmutzt

Rückspülen

 

 

 

 

Hauswasser Station nicht in Durchfluss-

Druckminderer in Durchflussrichtung

 

richtung montiert

montieren (Pfeilrichtung auf Gehäuse

 

 

beachten)

 

 

 

Eingestellter Hinterdruck bleibt nicht

Filtersieb verschmutzt

Rückspülen

konstant

 

 

Düse oder Dichtscheibe Ventileinsatz

Ventileinsatz ersetzen

 

 

verschmutzt oder beschädigt

 

 

 

 

 

Druckerhöhung auf Hinterdruckseite (z.B.

Funktion Rückflussverhinderer, Sicher-

 

durch Wassererwärmungsgerät)

heitsgruppe, usw. überprüfen

 

 

 

MU1H-1101GE23 R0109

6

Honeywell GmbH

 

 

 

D

12. Ersatzteile

Nr.

Bezeichnung

Nennweite

Artikel-Nummer

1

Federhaube komplett

1/2" + 3/4"

0901515

 

mit Einstellskala

1" + 11/4"

0901517

2

Ventileinsatz komplett

11/2" + 2"

0901518

1/2" + 3/4"

D06FA-1/2

 

(ohne Sieb)

1" + 11/4"

D06FA-1A

3

 

11/2" + 2"

D06FA-11/2

Dichtringsatz

1/2" + 3/4"

0901444

 

(10 Stück)

1"

0901445

 

 

11/4"

0901446

 

 

11/2"

0901447

4

 

2"

0901448

Einsteckrückfluss-

1/2"

2166200

 

verhinderer

3/4"

2110200

 

 

1"

2164400

 

 

11/4"

2164500

 

 

11/2"

2164600

5

Prüfventil

2"

2164700

1/2" - 2"

2421100

6

Manometer (0-10 bar)

 

M38K-A10

 

Manometer (0-16 bar)

 

M38K-A16

7

Manometer (0-25 bar)

 

M38K-A25

Filtereinsatz komplett*

1/2" - 3/4"

AF11S-1/2A

 

untere/obere Durch-

1" - 11/4"

AF11S-1A

8

lassweite 105/135 m

11/2" - 2"

AF11S-11/2A

Filtereinsatz komplett*

1/2" - 3/4"

AF11DS-1/2A

 

für Filter mit Double

1" - 11/4"

AF11DS-1A

 

Spin Technologie

 

 

 

untere/obere Durch-

 

 

9

lassweite 105/135 m

 

 

Klarsicht-Filtertasse

1/2" - 11/4"

KF11S-1A

10

komplett

11/2" - 2"

KF11S-11/2A

Rotguss-Filtertasse

1/2" - 11/4"

FT09RS-1A

11

komplett (o. Abb.)

11/2" - 2"

FT09RS-11/2A

O-Ring-Satz

1/2" - 11/4"

0900747

12

(10 Stück)

11/2" - 2"

0900748

Ablaufanschluss

1/2" - 2"

AA76-1/2A

13

Kugelhahn komplett

1/2" - 2"

KH11S-1A

14

Absperrkugelhahn

1/2"

2192900

 

(nicht enthalten bei

3/4"

2193100

 

HS10S-ZS)

1"

2193200

 

 

11/4"

2193300

 

 

11/2"

2193400

15

Doppelringschlüssel

2"

2193500

1/2" - 3/4"

ZR10K-3/4

 

zum Lösen der

 

Filtertasse und

1" - 11/4"

ZR10K-1

 

Federhaube (o. Abb.)

11/2" - 2"

ZR10K-11/2

13. Zubehör

Z11S Rückspülautomatik

Zum automatischen Rückspülen des Filters in einstellbaren Zeitintervallen

AF11S Filtereinsatz komplett

Erhältlich mit Filterfeinheit 20 m, 50 m, 100 m, 200 m, 300 m, 500 m

AF11DS Filtereinsatz komplett

Erhältlich mit Filterfeinheit 20 m, 50 m, 100 m, 200 m, 300 m, 500 m (für Filter mit Double Spin Technologie)

*Die Filterführung (für Filter mit bzw. ohne Double Spin Funktion) ist nur im Lieferumfang für Ersatzfiltereinsätze (AF11DS und AF11S) der Größen 1/2" bis 11/4 enthalten.

Honeywell GmbH

7

MU1H-1101GE23 R0109

 

 

 

GB

1. Safety Guidelines

1.Follow the installation instructions.

2.Use the appliance

according to its intended use

in good condition

with due regard to safety and risk of danger.

3.Note that the appliance is exclusively for use in the applications detailed in these installation instructions. Any other use will not be considered to comply with requirements and would invalidate the warranty.

4.Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons.

5.Immediately rectify any malfunctions which may influence safety.

2. Functional description

The domestic water station combines backflow preventer, reverse rinsing fine filter, pressure reducing valve and shut-off valve (not included on HS10S-ZS) into one unit.

Water flows first through the check valve. This causes the valve stem to push against the spring force and open the valve.

The downstream reverse rinsing fine filter holds back any dirt particles in the water. These particles are then completely flushed out by reverse rinsing.

Filters with Double Spin Technology have turbine blades which circulate the water and thereby set the rotor on the upper filter into a rotational motion. The internal impeller rinses off particles that have adhered to the upper filter at the intersecting points with the rotor.

The integral pressure reducing valve functions on a balanced force principle whereby the force exerted by a diaphragm is balanced against the force of an adjustment spring. The inlet pressure has no influence on opening or closing of the valve. Inlet pressure fluctuation does not therefore affect the outlet pressure.

3. Application

Medium

Water

Inlet pressure

Max. 16.0 bar with clear filter bowl

 

Max. 25.0 with red-bronze filter bowl

Outlet pressure 1.5 - 6.0 bar

The filter is constructed for drinking water installations. In case of a process water application the filter has to be proven individually.

4. Technical data

Installation position

Horizontal, with filter bowl downwards

Operating tempera-

Max. 40

°C with clear filter bowl

ture

Max. 70

°C with red-bronze filter bowl

Operating pressure

Min. 1.5 bar

Connection size

1/2" - 2"

 

5. Scope of delivery

The domestic water station comprises:

Housing with inlet and outlet pressure gauges

Check valve on inlet

Test point for check valve

Fine filter in clear filter bowl

Ball valve with drain connection

Spring bonnet with adjustment knob and setting scale

Valve insert complete with diaphragm and valve seat

Threaded or soldered union connections

Shut-off valve (not included on HS10S-ZS)

Double ring wrench

6. Options

HS10S-...AA = Threaded socket, upper/lower throughput

width 105/135 m

HS10S-...AAM = Red-bronze filter cup, threaded socket,

upper/lower throughput width 105/135 m HS10S-...ZS = Threaded socket, without shut-off valves,

upper/lower throughput width 105/135 m

Connection size

7. Assembly

7.1 Installations Guidelines

Install in horizontal pipework with filter bowl downwards o This position ensures optimum filter efficiency

Install shutoff valves

Ensure good access

o Pressure gauge can be read off easily

o Degree of contamination can be easily seen with clear filter bowl

o Simplifies maintenance and inspection

The installation location should be protected against frost

Fit immediately after water meter o Corresponds to DIN 1988, Part 2

7.2 Assembly instructions

When connecting the solder sockets, do not solder the sockets together with the domestic water station. High temperatures destroy internal parts which are important to the function!

First solder the sockets, then insert the available backflow preventers; only then should you install the domestic water station.

Observe the flow direction when mounting the backflow preventer.

1.Thoroughly flush pipework

2.Insert Venturi nozzle (only 2")

3.Install domestic water station o Note flow direction

o Install without tension or bending stresses

4.Seal in pressure gauge

Honeywell GmbH

8

MU1H-1101GE23 R0109

 

 

 

GB

7.3 Discharge of reverse rinsing water

The reverse rinsing water must be routed to the drain channel in such a way that no backwater can occur.

To do this there are 3 options:

1.Direct connection:

o Connector DN 50/70 as well as the necessary pipes and siphon (3 elbows 90°) in DN 70.

2.Drain free to existing floor drain.

3.Drain into open container.

Filter size

Reverse rinsing volume*

1/2" and 3/4"

12 litres

1" and 1 1/4"

15 litres

1 1/2" and 2"

18 litres

*at 4 bar inlet pressure and 3 x 3 seconds reverse rinsing duration

8. Commissioning

8.1 Setting outlet pressure

Set outlet pressure min. 1 bar under inlet pressure.

1.Close shutoff valve on inlet

2.Release pressure on outlet side (e.g. through water tap)

3.Close shutoff valve on outlet

4.Loosen slotted screw

o Do not remove slotted screw

5.Slacken tension in compression spring

o Turn control handle to the left (-) until it does not move any more

6.Slowly open shutoff valve on inlet

7.Retighten slotted screw

8.Slowly open shutoff valve on outlet

9.Turn control handle until the setting scale shows the desired value

8.2 Reverse rinsing

During reverse rinsing, an inlet pressure of at least 1.5 bar is required. The reverse rinsing interval depends on the degree of dirt in the water. At the latest every 2 months, reverse rinsing should be carried out according to DIN 1988, Part 8. To ensure convenient and regular adherence to the reverse rinsing interval, we recommend installing an automated

reverse rinsing system Z11S.

Filtered water can also be tapped during reverse rinsing.

8.2.1 Manual reverse rinsing

If reverse rinsing water is not to be discharged via a direct connection, a collecting container must be positioned beneath before reverse rinsing.

1.Open ball valve by turning the reverse rinsing button to the stop point

o Select bar must be upright

o The patented reverse rinsing system starts

o When filtering with Double Spin Technology, a visual function check is possible through the rotating red rotor

2.Close ball valve again after approx. 3 seconds. Repeat procedure three times

o If the filter is extremely dirty, the procedure may have to

be repeated additional times

With aid of the memory ring, the next deadline for manual reverse rinsing can be booked.

8.2.2 Automatic reverse rinsing with the Z11S

The automated reverse rinsing system Z11S is available as an accessory. The automated system reliably takes over reverse rinsing of the filter at intervals which can be set between 4 minutes and 3 months.

9. Maintenance

We recommend a planned maintenance contract with an installation company

In accordance with DIN 1988, part 8, the following measures must be taken:

9.1 Inspection

9.1.1 Pressure reducing valve

Interval: once a year

1.Close shut off valve on outlet

2.Check back pressure using a pressure meter when there is zero through-flow

o If the pressure is increasing slowly, the valve may be dirty or defective. In this instance, carry out servicing and cleaning

3.Slowly open shutoff valve on outlet

9.1.2 Filter

Interval: every 2 months

The filter must be cleaned by reverse rinsing regularly, at the latest every 2 months

Non-compliance can lead to the filter becoming blocked This results in a drop in pressure and decreasing water flow

The filter meshes are made of stainless steel. A red coating as a consequence of rust from the pipelines has no

influence on function or the way the filter works

Do not forget to do a visual check of the ball valve. Replace if it is dripping!

MU1H-1101GE23 R0109

9

Honeywell GmbH

 

 

 

GB

9.1.3 Check valve

Interval: once a year

1.Close shut off valve on outlet

2.Open check valve

o Until the pressure is released, some water will flow out of the check valve. After a short period of time the water flow should stop. If the water continues to drip or run, then the backflow preventer must be replaced - see servicing of backflow preventer

3.Close check valve again

4.Open shut-off valve again

9.2 Servicing

9.2.1 Pressure reducing valve

Frequency: every 1-3 years (depending on local operating conditions)

To be carried out by an installation company

1.Close shutoff valve on inlet

2.Release pressure on outlet side (e.g. through water tap)

3.Close shutoff valve on outlet

4.Loosen slotted screw

o Do not remove slotted screw Caution !

There is a spring in the spring bonnet. It may cause

injuries if the spring is derailing.

Make sure tension in compression spring is slakkened!

5.Slacken tension in compression spring

o Turn control handle to the left (-) until it does not move any more

o Do not turn in too far!

6.Unscrew spring bonnet

o Use double ring wrench ZR10K

7.Remove slip ring

8.Remove valve insert with a pair of pliers

9.Unscrew filter cup and guide piece o Use double ring wrench ZR10K

10.Remove slotted ring

11.Check that sealing ring, edge of nozzle and slotted ring are in good condition, and if necessary replace the entire valve insert

12.Reassemble in reverse order

Press in diaphragm with finger before inserting slip ring Screw in filter cup hand-tight (without tools)

13.Set outlet pressure

14.Set outlet pressure and adjust setting scale

9.3 Adjusting the setting scale

If the adjustment knob is removed, this setting is lost. A new setting can be achieved using a pressure gauge.

1.Close shutoff valve on inlet

2.Release pressure on outlet side (e.g. through water tap)

3.Close shutoff valve on outlet

4.Loosen slotted screw

o Do not remove slotted screw

5.Slowly open shutoff valve on inlet

6.Set desired outlet pressure (e.g. 4 bar)

7.Align scale (e.g. 4) in middle of viewing window

8.Retighten slotted screw

9.Slowly open shutoff valve on outlet

9.3.1 Filter

Interval: every 2 months

The filter must be cleaned by reverse rinsing regularly, at the latest every 2 months

Non-compliance can lead to the filter becoming blocked This results in a drop in pressure and decreasing water flow

The filter meshes are made of stainless steel. A red coating as a consequence of rust from the pipelines has no

influence on function or the way the filter works

Do not forget to do a visual check of the ball valve. Replace if it is dripping!

9.3.2 Check valve

To be carried out by an installation company

1.Close shutoff valve on inlet

2.Release pressure on outlet side (e.g. through water tap)

3.Close shutoff valve on outlet

4.Replace check valve

9.4 Cleaning

Caution !

Do not use any cleaning agents containing solvents and/or alcohol to clean the plastic parts!

5.Close shutoff valve on inlet and outlet.

6.Release pressure on outlet side (e.g. through water tap)

7.Close shutoff valve on outlet

8.Unscrew filter bowl

o Use double ring wrench ZR10K

9.Remove filter, clean and reinsert

10.Place O-ring onto filter bowl 11.Slowly open shutoff valve on inlet 12.Slowly open shutoff valve on outlet

Honeywell GmbH

10

MU1H-1101GE23 R0109

 

 

 

GB

10. Disposal

Dezincification resistant brass housing

Brass shutoff valve and connectors

High grade synthetic material check valve cartridge

Stainless steel fine filter

Red-bronze or shock-resistant, clear transparent synthetic material filter bowl

High-quality synthetic material spring bonnet

High-quality synthetic material valve insert

Fibre-reinforced NBR diaphragm

NBR seals

Observe the local requirements regarding correct waste recycling/disposal!

11. Troubleshooting

Problem

Cause

Remedy

Water is escaping from the spring

Diaphragm in valve insert is faulty

Replace valve insert

bonnet

 

 

 

 

 

Too little or no water pressure

Shut-off valves upstream or downstream

Open the shutoff valves fully

 

from domestic water station not fully open

 

 

 

 

 

Pressure reducing valve is not set to the

Set outlet pressure

 

desired outlet pressure

 

 

 

 

 

Filter mesh dirty

Reverse rinsing

 

 

 

 

Domestic water station not mounted in the

Fit pressure reducing valve in flow direction

 

direction of flow

(note direction of arrow on housing)

 

 

 

The outlet pressure set does not

Filter mesh dirty

Reverse rinsing

remain constant

 

 

Valve insert, sealing ring or edge of nozzle Replace valve insert

 

 

is contaminated or worn

 

 

 

 

 

Rising pressure on outlet (e.g. in boiler)

Check check valve, safety group etc.

 

 

 

MU1H-1101GE23 R0109

11

Honeywell GmbH

 

 

 

GB

12. Spare Parts

No. Description

Dimension

Part No.

1

Spring bonnet completet

1/2" + 3/4"

0901515

 

(with setting scale)

1" + 11/4"

0901517

 

 

11/2" + 2"

0901518

2

Valve insert complete

1/2" + 3/4"

D06FA-1/2

 

(without filter)

1" + 11/4"

D06FA-1A

 

 

11/2" + 2"

D06FA-11/2

3

Seal ring set

1/2" + 3/4"

0901444

 

(Pack of 10)

1"

0901445

 

 

11/4"

0901446

 

 

11/2"

0901447

 

 

2"

0901448

4

Check valve

1/2"

2166200

 

cartridge

3/4"

2110200

 

 

1"

2164400

 

 

11/4"

2164500

 

 

11/2"

2164600

 

 

2"

2164700

5

Test valve

1/2" - 2"

2421100

6

Pressure gauge (0-10 bar)

 

M38K-A10

 

Pressure gauge (0-16 bar)

 

M38K-A16

 

Pressure gauge (0-25 bar)

 

M38K-A25

7

Filter insert complete*

1/2" - 3/4"

AF11S-1/2A

 

Filter mesh 100 m

1" - 11/4"

AF11S-1A

 

 

11/2" - 2"

AF11S-11/2A

8

Filter insert complete* for

1/2" - 3/4"

AF11DS-1/2A

 

filters with Double Spin

1" - 11/4"

AF11DS-1A

 

Technology, Filter mesh

 

 

 

100 m

 

 

9

Clear filter bowl

1/2" - 11/4"

KF11S-1A

 

 

11/2" - 2"

KF11S-11/2A

10

Red-bronze filter bowl

1/2" - 11/4"

FT09RS-1A

 

 

11/2" - 2"

FT09RS-11/2A

11

O-ring set

1/2" - 11/4"

0900747

 

(Pack of 10)

11/2" - 2"

0900748

12

Drain connector

1/2" - 2"

AA76-1/2A

13

Ball valve complete

1/2" - 2"

KH11S-1A

14

Shutoff valve

1/2"

2192900

 

(not included in

3/4"

2193100

 

HS10S-ZS)

1"

2193200

 

 

11/4"

2193300

 

 

11/2"

2193400

 

 

2"

2193500

15

Double ring wrench

1/2" - 3/4"

ZR10K-3/4

 

for removing filter bowl

1" - 11/4"

ZR10K-1

 

and spring bonnet (no fig.)

11/2" - 2"

ZR10K-11/2

13. Accessories

Z11S

Automatic reverse rinsing actuator

 

For automatic filter cleaning at presettable intervals

AF11S

Filter insert complete

 

Available with filter meshes 20 m, 50 m,

 

100 m, 200 m, 300 m, 500 m

AF11DS

Filter insert complete

 

Available with filter meshes 20 m, 50 m,

 

100 m, 200 m, 300 m, 500 m (for filters with

 

Double Spin Technology)

*The filter guide (either with double spin or without double spin feature) is included in the packaging of the replacement filter inserts (AF11DS and AF11S) only for the sizes 1/2" up to 11/4!

Honeywell GmbH

12

MU1H-1101GE23 R0109

 

 

 

Position de
montage Température de
fonctionnement

F

1. Consignes de sécurité

1.Suivre les indications de la notice de montage.

2.En ce qui concerne l'utilisation de l'appareil

Utiliser cet appareil conformément aux données du constructeur

Maintenir l'appareil en parfait état

Respectez les consignes de sécurité

3.Il faut noter que cet équipement ne peut être mis en oeuvre que pour les conditions d'utilisation mentionnées dans cette notice. Toute autre utilisation, ou le non respect des conditions normales d'utilisation, serait considérée comme non conforme.

4.Observer que tous les travaux de montage, de mise en service, d'entretien et de réglage ne pourront être effectués que par des spécialistes autorisés.

5.Prendre des mesures immédiates en cas d'anomalies mettant en cause la sécurité.

2. Description fonctionnelle

La station d'eau domestique regroupe le clapet d'aspiration, le microfiltre rétro-lavable, ledécompresseur et le clapet d'arrêt (pas compris dans HS10S-ZS) en un seul appareil. Conformément à la disposition, c'est le clapet d'aspiration qui est d'abord traversé. Pendant le flux, un cône de soupape est pressé contre la force de ressort en position d'ouverture. Le microfiltre rétro-lavable retient les particules de saleté qui pourraient se trouver dans le medium. Lors du rétro-lavage, ces particules de saleté sont complètement éliminées.

Les filtres avec la technologie du Double Spin disposent d'une aube de turbine que l'eau fait tourner et qui ainsi met le rotor sur le tamis supérieur en mouvement de rotation. La turbine intérieure élimine aux points de contact avec le rotor les particules collant au tamis supérieur.

Le décompresseur intégré travaille selon le système de la comparaison des forces. Cela signifie, la force d'un ressort à valeur de consigne agit contre la force de la membrane. La pression d'entrée agit ni dans le sens d'ouverture ni de fermeture. C'est pourquoi les variations de pression sur la face n'influencent pas la pression à l'arrière.

3. Mise en oeuvre

Fluide

Eau

Pression amont

Max. 16,0 bar pour la cuve de filtre trans-

 

parente Max. 25,0 bar pour la cuve de

Pression aval

filtre en laiton

1,5 - 6,0 bar

L'appareil a été développé pour l'utilisation dans l'eau potable. L'utilisation dans les eaux de procédé est à contrôler de cas en cas.

4. Caractéristiques

Horizontal avec cuve de filtre vers le bas

Max. 40 °C pour la cuve de filtre transparente Max. 70 °C pour la cuve de filtre en

laiton Pression de service Min. 1,5 bar

Dimensions de

1/2" à 2"

raccordement

 

5. Contenu de la livraison

La station d'eau domestique se compose de :

Boîtier avec manomètre sur l'entrée et la sortie

Clapet d'aspiration à l'entrée

Clapet de contrôle pour le clapet d'aspiration

Microfiltre dans la cuve de filtre transparente

Clapet à bille avec raccord d'écoulement

Coiffe de ressort avec bouton de réglage

Garniture de soupape avec membrane et siège de soupape

Raccord fileté ou douille soudée

Clapet de fermeture (pas compris dans HS10S-ZS)

Clé polygonale double pour coiffe de ressort et cuve de filtre

6. Variantes

HS10S-...AA = Douille filetée, ouverture d'écoulement inférieure/supérieure 105/135 m

HS10S-...AAM = Cuve de filtre en laiton, douille filetée, ouverture d'écoulement inférieure/supérieure 105/135 m

HS10S-...ZS = Douille filetée, sans clapet de fermeture,

ouverture d'écoulement inférieure/supérieure 105/135 m

Taille du raccord

7. Montage

7.1 Dispositions à prendre

Installer dans la tuyauterie horizontale avec le bocal du filtre vers le bas

o Cette position assure une efficacité de filtrage optimale

Prévoir des soupapes d'arrêt

Veiller à un accès facile

o Manomètre facile à observer

o Degré de salissure pour la cuve de filtre transparente bien visible

o Simplifie la maintenance et l'inspection

Monter directement après le compteur d'eau o conformément à la DIN 1988, partie 2

Honeywell GmbH

13

MU1H-1101GE23 R0109

 

 

 

Loading...