GENERAL

Capsule:

Amplifier:

Power Supply:

Microphone Cable:

Mounting Thread:

Dimensions:

Weight:

Finish:

Environmental Temperatures:

Recommended Optional

Accessory:

PERFORMANCES

Frequency Response:

Directivity:

Output Impedance:

Output Level:

Maximum Sound Pressure

Input Level:

Dynamic Range:

SPECIFICATIONS

Electret condenser capsule Sony junction FET Battery operation with

Manganese

EVEREADY 216

Mercury

EVEREADY E146

External power operation facility

5.2mm (7/32") dia., 2-conductor shielded cable, 6m (20ft), freeend

PF1/2 -14 thread

50 mm max. dia. x 207 mm (2" max. dia. x 81/4")

500g (1 Ib 1 oz) microphone only Non-reflective satin nickel finish

-20°C to 60°C (-4°F to 140°F) for storage

0°C to 60°C (32°F to 140°F) for operation

External power supply AC-148F

20 Hz -20,000 Hz Uni-directional

250 ohm ±20% at 1,000 Hz, balanced

Effective output level -53.8 dBm (0dBm = 1 mW/10ju bar, 1,000 Hz) Open circuit voltage 0.2mV/u bar, at 1,000 Hz

Output level diviation ±2dB Recommended load impedance is more than 3

Approx. 134dB SPL

Approx. 106dB

NOISE LEVEL Signal-

to-noise Ratio: More than 46 dB (1,000 Hz, 1 jubar)

Inherent Noise: Less than 28 dB SPL (0 dB SPL = 2x 10-4 ubar) Less than 40dB SPL

Wind Noise *1: Less than 5 dB SPL/m gauss

Induction Noise From *1 Wind noise is the value measured by External Magnetic applying a wind velocity of 6.6ft/second from all

Field *2: directions on the microphone. The mean value is obtained and converted to the equivalent input sound level. 0dB = 2x10-4 ubar

*2 The external magnetic field

induction noise is measured by placing the microphone in an alternating magnetic field of 50 Hz, 1 m gauss. The maximum noise value is measured and then converted to the equivalent input sound level. 0dB = 2x 10-4 ubar

POWER REQUIREMENTS

9 V DC (battery operation)

24V-54V DC (external power operation)

7 V DC

Less than 1 mA (with battery)

Normal Operating Voltage: Less than 3.5 mA

(with external power supply)

Battery Life:

Minimum Operating Approx 400 hours with EVEREADY 216 Voltage: (manganese)

Current Drain: Approx. 600 hours with EVEREADY E146 (mercury)