Philips Energy Advantage User Manual

Page 1
Maximum energy savings,
environmentally-responsible
fluorescent lamps
Philips Energy Advantage Long Life 25W T8 Lamps
Page 2
Switching from Standard 4-Ft Linear Fluorescent 32W T8
to Energy Advantage Long Life 25W T8
Number of 3-Lamp Fixtures
To t al Savings Over Lamp Life
$700,000
$600,000
$500,000
$400,000
$300,000
$200,000
$100,000
$0
Total Savings Over Lamp Life = Savings Over Lamp Life x 3 x Number of Fixtures. Lamp Life = 30,000 Hours @ 12 Hours per Start on Instant Start Ballast. Annual Operating Hours = 4380 (12 Hours a Day x 365 Days per Year).
2000 4000 6000 8000 10,000
$252K
$378K
$504K
$630K
$126K
> Sustainable Lighting Solution—Less
mercury and fewer lamps in landfills, combined with energy efficiency, safer for on the environment
> Featuring ALTO
> Our Green End-Caps
environmentally-responsible lamps
> Operates on any ANSI approved instant
start ballast
®
Lamp Technology
®
mean you are using
Page 3
Energy Advantage Long Life 25W T8 Lamps
versus Standard 32W T8 Lamps
Why choose the Energy Advantage Long Life 25W T8 over 32W T8 lamps? It’s simple.The 25W design makes it the lowest
energy consuming 4-foot T8 lamp on the market, and the 7-watt reduction translates into up to 25% energy savings versus a standard 32W T8.That means the Energy Advantage Long Life 25W T8 puts money in your pocket.
> Simple replacement for existing 32 Watt T8
> Maximum energy savings—Consumes the least amount of
energy of any 4-foot T8 fluorescent lamp on the market
> Outstanding illumination quality—Hi-Vision®phosphor
delivers 95% lumen maintenance and 85 CRI
> Outstanding lumen maintenance
Energy Advantage Long Life 25W T8 System vs F32T8 System
3 LAMP SYSTEM 4 LAMP SYSTEM
Standard Energy Advantage Standard Energy Advantage F32T8 Long Life 25W T8 F32T8 Long Life 25W T8 .87 BF* .87 BF* .87 BF* .87 BF*
System Wattage 88 67 112 84
Maintained 2800 x .87 2400 x .87 2800 x .87 2400 x .87 Lumens BF* x .95 LM BF* x .95 LM BF* x .95 LM BF* x .95 LM
x 3 = 6943 x 3 = 5951 x 4 = 9257 x 4 = 7934
Energy Savings 21 WATTS SAVED! 28 WATTS SAVED!
*Ballast Factor (BF) Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast.
Replace Existing 32W T8 Systems with
Energy Advantage Long Life 25W T8 Systems &
Save Up To 25% in Energy Costs!
Dollars Saved Over the Life of
Energy Advantage Long Life 25W T8 Lamps vs Standard F32T8 Lamps
Energy Savings Calculator
7 Watts per Annual Operating Hrs. Annual Operating Hrs. SAVINGS OVER Lamp Saved (12 hour cycle) (24 hour cycle) LAMP LIFE
kWh Rate 4380* 8760** 30,000 Hours
$0.06 $1.84 $3.68 $12.26
$0.08 $2.45 $4.90 $16.80
$0.10
$0.12 $3.68 $7.36 $25.20
$0.20 $6.13 $12.60 $42.00
*4380 based on operating the lamps 12 hours per day/7 days per week. **8760 based on operating the lamps 24 hours per day/7 days per week.
$3.07
$6.13
$21.00
Page 4
Energy Advantage Long Life 25W T8 Lamps
versus Standard F34T12 Lamps
Replacing existing F34T12 magnetic systems with Energy Advantage Long Life 25W T8 lamps on instant start ballasts, results in an energy savings of up to 60-watts per fixture! That’s approximately a 40% energy savings.The Energy Advantage Long Life 25W T8 is ideal for office environments that are currently overlit with antiquated T12 lamps and need more energy efficiency without sacrificing light quality.
> Save 60-watts per fixture by replacing a 4 lamp
T12 magnetic ballast system with a 4 lamp 25W T8 instant start ballast system
> Improves CRI from 62 to 85
Energy Advantage Long Life 25W T8 System vs F34T12/EW System
3 LAMP SYSTEM 4 LAMP SYSTEM
Standard Energy Advantage Standard Energy Advantage F34T12/EW Long Life 25W T8 F34T12/EW Long Life 25W T8 .87 BF* .87 BF* .87 BF* .87 BF*
System Wattage 115 64 144 84
Maintained 2650 x .87 2400 x .87 2650 x .87 2400 x .87 Lumens BF* x .87 LM BF* x .95 LM BF* x .87 LM BF* x .95 LM
x 3 = 6017 x 3 = 5951 x 4 = 8023 x 4 = 7934
Energy Savings 51 WATTS SAVED! 60 WATTS SAVED!
*Ballast Factor (BF) Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast.
Replace Existing 34W T12 Systems with
Energy Advantage Long Life 25W T8 Systems &
Save Up To 40% in Energy Costs!
Dollars Saved Over the Life of
Energy Advantage Long Life 25W T8 System vs Standard F34T12 System
Energy Savings Calculator
15 Watts per Annual Operating Hrs. Annual Operating Hrs. SAVINGS OVER Lamp Saved (12 hour cycle) (24 hour cycle) LAMP LIFE
kWh Rate
$0.06 $3.94 $7.88 $27.00
$0.08 $5.26 $10.52 $36.00
$0.10
$0.12 $7.88 $15.76 $54.00
$0.20
*4380 based on operating the lamps 12 hours per day/7 days per week. **8760 based on operating the lamps 24 hours per day/7 days per week.
4380*
$6.57
$13.14
8760**
$13.14
$26.28
30,000 Hours
$45.00
$90.00
Page 5
Energy Advantage Long Life 25W T8 Lamps
versus Competitive Energy Savings T8 Lamps
Stacking up against the competition. the Energy Advantage Long LIfe 25W 4-foot T8 lamps lead the industry in energy savings over life versus competitive low wattage 4-foot T8 lamps.
Energy Savings Comparison when Replacing a 32W T8 with an Energy
Advantage Long Life 25W T8 Lamps or GE UltraMax™28W T8 Lamps
Savings Over Lamp Life
GE UltraMax 28 Watt T8 Long Life 25W T8
Philips Energy Advantage
1
The Philips
Extra Savings
Saves 4 Watts Saves 7 Watts
kWh Rate 24,000 Hours
$0.06 $6.91 $12.60 $5.69
$0.08 $7.68 $16.80 $9.12
$0.10 $9.60 $21.00 $11.40
$0.12 $11.52 $25.20 $13.68
$0.20 $19.20 $42.00 $22.80
1. Hours x kWh Rate x Watts Saved ÷ 1000.
2. Information taken from GE Web site based on product sell sheets and product brochures in effect on 4/1/05.
3. Average life under engineering data with lamps turned off and restar ted once every 12 operating hours.
2
30,000 Hours
3
vs GE 28 Watt
Energy Savings Comparison when Replacing a 32W T8 with an Energy
Advantage Long Life 25W T8 Lamps or OSI Octron®XP™SS 28W T8 Lamps
Savings Over Lamp Life
OSI XP™SS Philips Energy Advantage 28 Watt T8 Long Life 25W T8
1
The Philips
Extra Savings
Saves 4 Watts Saves 7 Watts
kWh Rate 26,000 Hours
$0.06 $6.24 $12.60 $6.36
$0.08 $8.32 $16.80 $8.48
$0.10 $10.40 $21.00 $10.60
$0.12 $12.48 $25.20 $12.72
$0.20 $20.08 $42.00 $21.92
1. Hours x kWh Rate x Watts Saved ÷1000.
2. Information taken from OSI Web site based on product sell sheets and product brochures in effect on 4/1/04.
3. Average life under engineering data with lamps turned off and restar ted once every 12 operating hours.
2
30,000 Hours
3
vs OSI 28 Watt
Page 6
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
rinted in USA 4/05 P-5671-A
P
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
Division of Philips Electronics Ltd.
A
Energy Advantage Long Life 25W T8 Lamps featuring ALTO®Lamp Technology
Electrical,Technical and Ordering Data (Subject to change without notice)
Product Ordering Lamp Temp. Length Life (Hrs.) Initial Design Lumen Number Code Wattage (Kelvin) (In.) 12-Hr. Start
E
13781-0 F32T8/ADV830/XEW/ALTO 25 3000K 48 30,000 2400 2280 85 95%
E
13782-8 F32T8/ADV835/XEW/ALTO 25 3500K 48 30,000 2400 2280 85 95%
E
13783-6 F32T8/ADV841/XEW/ALTO 25 4100K 48 30,000 2400 2280 85 95%
E
13784-4 F32T8/ADV850/XEW/ALTO 25 5000K 48 30,000 2400 2280 85 95%
1) Average life under engineering data with lamps turned off and restarted once ever y 12 operating hours. Not recommended for use with occupancy or motion sensors on instant star t ballasts.
2) The lamp lumen output is based upon lamp performance after100 hours of operating life, when the output is measured during operation on a reference ballast under standard laborator y conditions. For expected lamp lumen output, c
ommercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.
3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laborator y conditions. Lamp meets US Feder
E
al Minimum Efficiency Standards.
Color Nominal Rated Average Approx.
1
Lumens
2
Lumens3CRI Maintenance
Products that utilize ALTO®Lamp Technology introduce less mercury into the environment.
Reduce Philips ALTO®fluorescent lamps combine low mercury
with long life and energy efficiency—which together help achieve sustainability:
> Low Mercury Philips ALTO lamps average 70 percent less
mercury than the 2001 industry average for fluorescent lamps
4
up to 60" which are not TCLP
-compliant. Source reduction during the manufacturing phase is essential to mercury management throughout the product lifecycle.
> Long Life Philips ALTO PLUS T8 lamps achieve 50 percent
longer life than standard T8 lamps, safer for the environment.
> Energy Efficiency Energy-efficient lighting not only reduces
operating costs; it also supports a clean and sustainable environment.
TCLP is the US EP
The
4)
5) War ranties: Universal T8, 24 months; Energy Advantage Long Life 25W T8, 24 months; PLUS T8, 30 months; Advantage T8, 36 months.
A’s Toxicity Characteristic Leaching Procedure.
Reuse ALTO lamps use 100 percent recycled mercury
during the ALTO manufacturing process.
Recycle Philips encourages recycling of all spent mercury-
containing lamps at end of life. For information on recycling regulations in your state go to www.lamprecycle.org.
Did You Know?
ALTO T8 lamps have warranty periods ranging from
>
2–3 y
ears
5
.
> ALTO T8 require no burn in before dimming.
> ALTO T8 lamps can contribute to LEED-EB certification.
For more information go to www.usgbc.org.
> Since 1995 over one billion ALTO lamps have been
installed nationwide
.
Loading...