Miele PM1217, PM1210, PM1214 Installation Manual

0 (0)
Miele PM1217, PM1210, PM1214 Installation Manual

Installation Plan

Commercial Rotary Iron

PM 1210

PM 1214

PM 1217

To avoid the risk of accidents or damage to the

en - US

machine, it is essential to read these instructions

 

before it is installed and used for the first time.

 

 

M.-Nr. 09 981 760

Contents

 

Notes for installer ................................................................................................................

3

Installation .............................................................................................................................

3

Setting up the rotary iron.......................................................................................................

4

Mounting the toe-kick (optional)............................................................................................

4

Install the laundry box on the laundry outfeed table. ............................................................

4

Duct for venting steam ..........................................................................................................

4

Substitute duct lengths .....................................................................................................

5

Maximum permissible total duct length ............................................................................

5

Electrical connection .............................................................................................................

6

Installation Plan ...................................................................................................................

7

Flatwork ironer PM 1210, PM 1214, PM 1217 ......................................................................

7

Technical details ..................................................................................................................

8

2

Notes for installer

The rotary iron should be installed by a Miele trained installer.

Storage of the machine

The following conditions must be observed for transport and storage:

Temperature: minimum of - 77°F / 25°C to maximum of 131°F / 55°C

Humidity: minimum of 5% to maximum of 75%, non-condensing

Maximum storage period: 2 years

Operating conditions

In general, the operating conditions of DIN 60204 and EN 60204-1 apply.

Temperature and relative humidity

Temperature: 40°F / 5°C - 104°F / 40°C Relative humidity: 10% - 85%

At 70°F (21°C) ambient temperature, the maximum permissible relative humidity is 70%.

Do not operate the machine in a room where cleaning machines operate with solvents containing PERC or CFC.

Motor sparking may convert solvent va pors into hydrochloric acid which can lead to consequential damage.

Installation

The machine is transported to the installa tion site while still in the packaging. Do not remove the packaging until right before in stallation.

The machine may be transported or lifted from the wooden frame only with the lat eral mounting flaps mounted.

First lift the machine at the installation site by the wooden frame. The suspension points for lifting hooks/straps are located under the side columns between the screwon feet.

During installation, remember that the clear ance next to and behind the machine col umns must amount to at least 23 5/8" (600mm) so that the side plates remain ac cessible.

The machine should be set up so that the light shines parallel to the infeed table as much as possible.

The clearance in front of the machine must amount to at least 60" (1.5m) to prevent a heating of foreign materials (furniture, walls). There should be a clearance of at least 39" (1m) above the machine.

A base and anchoring means are not neces sary.

During the transport of the machine, pay attention to its stability. The iron may not be transported without the wooden frame (e.g., in case of a move). For a new trans port, lift the iron onto the wooden frame and fasten it there.

3

Notes for installer

Setting up the rotary iron

Dismantle the mounting flaps on the left and right sides.

Check the roller and front and outside of the side columns using a level.

Align the machine using the screw-on feet in such a way that the side columns and roller are level with each other. In the process, the feet may be unscrewed a maximum of 2 3/8" (60mm).

Counter the screw-on feet according to the alignment using the nuts (under the side columns).

Mounting the toe-kick (optional)

Mounting the optionally available toe-kick can raise the machine by 4" (100mm).

Dismantle the mounting flaps on the left and right sides.

Unscrew the screw-on feet by the maxi mum amount (> 2 3/8" (60mm)).

Hold the side columns with a suitable aid and remove the screw-on feet.

Mount the screw-on feet into the toe-kick and push the toe-kick under the column.

Screw the toe-kick to the base plate of the machine.

Install the laundry box on the laun dry outfeed table.

During installation, bring the laundry shelf into a horizontal position.

Loosen the fastening screws of the laun dry shelf.

Rotate the laundry box by 180° and mount with the fastening screws on the laundry outfeed table.

Duct for venting steam

Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork It must also be laid sep arately to any exhaust air duct used for a laundry dryer.

The moist warm exhaust air must be vented to the outdoors by the shortest route possi ble. To ensure optimum air flow, the ducting should contain as few bends as possible and airtight connections. Filters and louvers may not be installed into the exhaust duct.

Since the relative humidity can amount to up to 100%, suitable measures must be taken to prevent condensate from flowing back into the machine. If the available pres sure of the machine fan for overcoming con ductor resistance does not suffice, an ac cording dimensioned additional fan must be installed in the shaft or roof outlet on-site. Ensure that there is sufficient ventilation in the room where the ironer is installed

The connection for the exhaust air duct for steam extraction (optional for PM 1210) is located on the rear of the left side column and has a diameter of 2 3/4" (70mm).

The exhaust air duct must have an internal diameter of 2 3/4" (70mm).

To prevent the build-up of condensation in an upward sloping exhaust ducting, a 1/8" - 3/16" (3-5mm) ø condensate trap should be fitted at the lowest point.

Ensure that there is sufficient ventilation in the room where the ironer is installed

The on-site ducting system and the exit point to the outside must be checked on a regular basis for a build-up of lint and cleaned if required.

The air duct leading into the open should be protected against the elements, e.g. using a suitable hood or grille or with a 90° bend.

4