Miele KWT2661SFS, KWT2611SF, F2671SF, KWT2601Vi, KWT2611Vi Specifications

...
0 (0)
Miele KWT2661SFS, KWT2611SF, F2671SF, KWT2601Vi, KWT2611Vi Specifications

Fully Integrated

24” MasterCool II

K 2601 Vi / K 2611 Vi

F 2601 Vi* / F 2611 Vi* KWT 2601 Vi / KWT 2611 Vi

KWT 2661 ViS / KWT 2671 ViS

Shown: KWT 2611 Vi

8miele.ca

Please note: This information is subject to change

Specification Sheets TRS 04252019

*The following models are not available in Canada : F 2601 Vi & F 2611 Vi

 

Fully Integrated

24” MasterCool II

 

SPECIFICATIONS

 

 

 

 

 

 

Overall Unit Dimensions

233/4” (604 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]

 

 

Niche

 

 

 

 

 

 

Minimum Cabinet Niche Opening

24” (610 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D

 

 

Interior Volume

K 26x1 Vi

KWT 26x1 Vi

 

F 26x1 Vi

 

 

Refrigeration Volume

**

**

 

0

 

 

Freezer Volume

0

0

 

**

 

 

Chiller Volume

0

**

 

0

 

 

Electrical

K 26x1 Vi

KWT 26x1 Vi

 

F 26x1 Vi

 

 

Electrical Requirements

 

110V / 120V, 60Hz, 15 Amps

 

 

In the case of side-by-side installations, a separate outlet must be used for each appliance.

 

 

 

 

 

Power Cord

 

NEMA 5-15 plug, 5 ft (1.52 m)

 

 

 

 

 

 

 

 

 

Plumbing

K 26x1 Vi

KWT 26x1 Vi

 

F 26x1 Vi

 

 

 

 

 

 

Connect to a cold water supply only. Do not connect to a

 

 

 

 

 

 

low-mineral or a reverse osmosis system. Must be connected

 

 

Water Supply Requirements

-

 

 

to a shut-off valve. The water shut-off valve must be accessible

 

 

 

 

after installation. The water pressure must be between 29 psi

 

 

 

 

 

 

 

 

 

 

 

 

(2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi

 

 

 

 

 

 

(8.3 bar), a pressure reducing valve must be installed.

 

 

Water Connection Line

-

 

 

Standard 1/4” O.D flexible water line. The maximum outer

 

 

 

 

diameter of the water pipe (without fittings): 3/8” (10 mm).

 

 

 

 

 

 

Water line is not included.

 

 

Shipping

K 26x1 Vi

KWT 26x1 Vi

 

F 26x1 Vi

 

 

Shipping Weight

346 lbs (157 kg)

357 lbs (162 kg)

 

375 lbs (170 kg)

 

 

Shipping Dimensions

 

267/8” (682 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D

 

 

Support

 

 

 

 

 

 

Call Miele

 

 

(800) 565-6435

 

 

 

 

 

 

 

 

Miele Website

 

 

8www.miele.ca

 

 

20/20 Link

 

 

82020technologies.com

 

Please note the following:

This specification sheet is for a single built-in unit.

When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet.

*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of

 the Heating Mat/Merge Kit.

K 2601 Vi (Right Hinged)

F 2661 Vi (Right Hinged)

KWT 2601 Vi (Right Hinged)

KWT 2661 ViS (Right Hinged)

K 2611 Vi (Left Hinged)

F 2671 Vi (Left Hinged)

KWT 2611 Vi (Left Hinged)

KWT 2671 ViS (Left Hinged)

Page 2 of 12

Fully Integrated

24” MasterCool II

CUTOUT DIMENSIONS

Niche depth assumes a 3/4” (19 mm) panel, please   adjust according to custom panel thickness

CUTOUT DETAILS

The electrical connection must not be positioned higher   than 9” (228.6 mm) above the floor.

The 1/4” (6.4 mm) plumbed water connection should

  not be positioned higher than 2” (50.8 mm) above the   floor.

Notes:

In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.

Page 3 of 12

Fully Integrated

24” MasterCool II

POWER SUPPLY AND WATER CONNECTION (Water Connection For F 26x1 Vi Only)

Rear View

Front View

Electrical  - 5 foot (1.52 m) - 120 Volt - 15 Amp

Water connection is located in front of unit.

 - NEMA 5-15 molded plug

1/4” compression fitting is needed.

Water line - 1/4” flexible water line - not included

 

Side View

Electrical

Connection