Fully Integrated
24” MasterCool II
K 2601 Vi / K 2611 Vi
F 2601 Vi* / F 2611 Vi* KWT 2601 Vi / KWT 2611 Vi
KWT 2661 ViS / KWT 2671 ViS
Shown: KWT 2611 Vi |
8miele.ca |
Please note: This information is subject to change |
Specification Sheets TRS 04252019 |
*The following models are not available in Canada : F 2601 Vi & F 2611 Vi |
|
Fully Integrated
24” MasterCool II
|
SPECIFICATIONS |
|
|
|
|
|
|
Overall Unit Dimensions |
233/4” (604 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel] |
|
|||
|
Niche |
|
|
|
|
|
|
Minimum Cabinet Niche Opening |
24” (610 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D |
|
|||
|
Interior Volume |
K 26x1 Vi |
KWT 26x1 Vi |
|
F 26x1 Vi |
|
|
Refrigeration Volume |
** |
** |
|
0 |
|
|
Freezer Volume |
0 |
0 |
|
** |
|
|
Chiller Volume |
0 |
** |
|
0 |
|
|
Electrical |
K 26x1 Vi |
KWT 26x1 Vi |
|
F 26x1 Vi |
|
|
Electrical Requirements |
|
110V / 120V, 60Hz, 15 Amps |
|
||
|
In the case of side-by-side installations, a separate outlet must be used for each appliance. |
|
||||
|
|
|
||||
|
Power Cord |
|
NEMA 5-15 plug, 5 ft (1.52 m) |
|
||
|
|
|
|
|
|
|
|
Plumbing |
K 26x1 Vi |
KWT 26x1 Vi |
|
F 26x1 Vi |
|
|
|
|
|
|
Connect to a cold water supply only. Do not connect to a |
|
|
|
|
|
|
low-mineral or a reverse osmosis system. Must be connected |
|
|
Water Supply Requirements |
- |
|
|
to a shut-off valve. The water shut-off valve must be accessible |
|
|
|
|
after installation. The water pressure must be between 29 psi |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
(2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi |
|
|
|
|
|
|
(8.3 bar), a pressure reducing valve must be installed. |
|
|
Water Connection Line |
- |
|
|
Standard 1/4” O.D flexible water line. The maximum outer |
|
|
|
|
diameter of the water pipe (without fittings): 3/8” (10 mm). |
|
||
|
|
|
|
|
Water line is not included. |
|
|
Shipping |
K 26x1 Vi |
KWT 26x1 Vi |
|
F 26x1 Vi |
|
|
Shipping Weight |
346 lbs (157 kg) |
357 lbs (162 kg) |
|
375 lbs (170 kg) |
|
|
Shipping Dimensions |
|
267/8” (682 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D |
|
||
|
Support |
|
|
|
|
|
|
Call Miele |
|
|
(800) 565-6435 |
|
|
|
|
|
|
|
|
|
|
Miele Website |
|
|
8www.miele.ca |
|
|
|
20/20 Link |
|
|
82020technologies.com |
|
Please note the following:
•This specification sheet is for a single built-in unit.
•When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
K 2601 Vi (Right Hinged) |
F 2661 Vi (Right Hinged) |
KWT 2601 Vi (Right Hinged) |
KWT 2661 ViS (Right Hinged) |
K 2611 Vi (Left Hinged) |
F 2671 Vi (Left Hinged) |
KWT 2611 Vi (Left Hinged) |
KWT 2671 ViS (Left Hinged) |
Page 2 of 12
Fully Integrated
24” MasterCool II
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please adjust according to custom panel thickness
CUTOUT DETAILS
•The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.
•The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the floor.
Notes:
In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 12
Fully Integrated
24” MasterCool II
POWER SUPPLY AND WATER CONNECTION (Water Connection For F 26x1 Vi Only)
Rear View |
Front View |
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp |
Water connection is located in front of unit. |
- NEMA 5-15 molded plug |
1/4” compression fitting is needed. |
Water line - 1/4” flexible water line - not included |
|
Side View
Electrical
Connection
Page 4 of 12