KEYENCE OP-87437 User Manual

96M11892
IV Series Polarizing Filter Attachment
OP-87436 / OP-87437
Instruction Manual
Read this manual before using the product in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time. For details of functions, refer to the IV Series User's Manual (Monitor) or the IV Series User's Manual (PC Software).
The IV Series User's Manual can be downloaded from the
y
KEYENCE web site: http://www.keyence.com/

Symbols

The following symbols alert you to important messages. Be sure to read these messages carefully.
It indicates a hazardous situation which, if not avoided, will result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product damage as well as property damage.
It indicates cautions and limitations that must be followed during operation.
It indicates additional information on proper operation.
It indicates tips for better understanding or useful information.

Cautions

(1) Unauthorized reproduction of this manual in whole or
part is prohibited.
(2) The contents of this manual may be changed for
improvements without prior notice.
(3)
An utmost effort has been made to ensure the contents of this manual are as complete as possible. If there are any
mistakes or questions, please contact a KEYENCE ofce
listed in the back of the manual.
(4) Regardless of item (3), KEYENCE will not be liable for
any effect resulting from the use of this unit.
(5) Any manuals with missing pages or other paging faults
will be replaced.
The company names and product names used in this manual are registered trademarks or the trademarks of their respective companies.

Safety Information for IV series

General Precautions

Do not use this product for the purpose to
y
protect a human body or a part of human body. This product is not intended for use as an
y
explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere.
You must verify that the IV Series are operating
y
correctly in terms of functionality and performance before the start and the operation of the IV Series. We recommend that you take substantial
y
safety measures to avoid any damage in the event of a problem occurring.
KEYENCE never warrants the function or
y
performance of the IV Series if it is used in manner
that differs from the IV Series specications
contained in this instruction manual or if the IV
Series are modied by yourself.
When the IV Series is used in combination with
y
other instruments, functions and performance may be degraded, depending on operating conditions and the surrounding environment. Do not place the instruments, including
y
peripherals, under rapid temperature change. It may cause condensation and may damage instruments or peripherals. Remove the power cable from the power
y
supply if you do not use this product for a long time.

Important Instructions

Observe the following precautions to prevent malfunction of the IV Series and to ensure that it is used properly.

Precautions on use

For instructions
y
Do not let water, dust or oil stick to the
y
camera/light of the sensor. Failure to do so may cause a malfunction. When this product becomes dirty, do not
y
rub it with a wet cloth, benzene, thinner, or alcohol. Doing so may change the color or shape of the unit. If the unit is heavily contaminated,
y
disconnect all the cables including the power supply cable, wipe off the dirt with a cloth soaked with mild detergent, and then wipe with a soft dry cloth.
There are the polarized visible light lter
y
attachment (OP-87436) and the infrared
polarization lter attachment (OP-87437). Use the correct polarization lter attachment
according to the lighting of the sensor. Failure to do so may lose the effect. Adjust the brightness with the polarization
y
lter attachment mounted.
Adjust the white balance with the polarization
y
lter attachment mounted for color type.

Measures to be taken when an abnormality occurs

In the following cases, turn the power OFF immediately. Using the IV Series in an abnormal
condition could cause re, electric shock, or malfunction. Contact our ofce for repair.
If water or debris enters the IV Series.
y
If the IV Series is dropped or the case is damaged.
y
If abnormal smoke or odor emanates from
y
the IV Series.

Precautions on installation

To use this product correctly and safely, avoid installing it in the following locations. Failure to do
so may cause re, electric shock, or malfunction.
Outdoors
y
Altitude above 2000 m
y
Locations that are humid, dusty or poorly
y
ventilated Locations where the temperature is high
y
such as those exposed to direct sunlight
Locations where there are ammable or
y
corrosive gases Locations where the unit may be directly
y
subjected to vibration or impact Locations where water, oil, or chemicals
y
may splash onto the unit
1
IV Series (Polarizing Filter Attachment) - IM_E

Checking the Package Contents

32
32
Polarized visible light lter attachment
OP-87436
y
Mounting screw x 2 Instruction Manual x 1
(This manual)
Polarized visible light lter
attachment x 1
Infrared polarization lter attachment
OP-87437
y
Mounting screw x 2 Instruction Manual x 1
(This manual)
Infrared polarization lter
attachment x 1

Mounting the attachment

Do not remove the front cover of the sensor.
Mount the attachment by aligning the concave part of
1
the polarizing lter attachment with the mounting screw
of the front cover of the sensor.
Screw hole for mounting the
Front cover
mounting screw
Concave
part
Fix the polarizing lter attachment with the
2
attached dedicated screws.
Screw : M2.5 x 2
y
Use the attached dedicated screws.
Retightening torque : 0.25 to 0.35 N·m
y
attachment
Concave part
When it is mounted on the sensor
φ56
5
Distance from WD reference surface
Specications
Model OP-87436 OP-87437
Compatible sensor Visible light type Infrared light type
Weight Approx. 15 g
* The enclosure rating (IP67) is not maintained when the
polarizing lter attachment is used.

Warranties and Disclaimers

(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper
interfacing, improper repair, unauthorized modication, misapplication and
mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
tness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/ Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S
CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a
third party, Buyer must provide such third party with a copy of this document, all
specications, manuals, catalogs, leaets and written information provided to
Buyer pertaining to the Products/Samples.

Dimensions

Single polarizing lter attachment
φ56
IV Series (Polarizing Filter Attachment) - IM_E
Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
1121-1 96M11892 Printed in Japan
2
Loading...