Electrolux EFME427UIW User Manual

0 (0)
Electrolux EFME427UIW User Manual

Dryer Tech Data Sheet 1

This information is intended for Qualified Technicians Only.

 

TABLE OF CONTENTS

 

Dryer Tech Data Sheet...........................................................................

1

Diagnostic Mode Tests/Demo Mode.......................................................

2

Dryer Error Codes..................................................................................

3

Wiring Diagrams...................................................................................

10

Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described below:

This symbol alerts you to situations that may WARNING cause serious body harm, death or property

damage.

CAUTION

This symbol alerts you to situations that may

cause bodily injury or property damage.

Push Button Cycle Select Dryer User Interface

1

 

2

 

3

Rotary Dial Cycle Select Dryer User Interface

1

 

2

 

3

CAUTION

Unless otherwise directed, disconnect electrical current before servicing.

 

 

 

 

 

 

1

power

 

 

 

 

 

 

2

cycle status display

 

 

 

 

 

 

3

cycle selector

 

 

 

 

 

 

4

temperature

4

5

6

7

8

9

10

 

 

 

 

 

 

 

5

dryness (dry level)

 

 

 

 

 

 

6

time dry (dry time)

 

 

 

 

 

 

7

options

 

 

 

 

 

 

8

select (set)

 

 

 

 

 

 

9

cancel

 

 

 

 

 

 

10

start / pause

4

5

6

7

8

9

10

 

Entering Diagnostic Mode:

1.Press power and look for console light up.

2.Rotate cycle selector ring (on some models) or repeatedly press cycle button (on other models) to set cycle to normal.

3.Press the start button.

4.Power off machine by pressing the power button.

5.Power on machine by pressing the power button again.

6.Within 10 seconds, simultaneously hold temp + select (set) buttons together for 3 seconds.

7.Diagnostic Mode is active when LED’s start blinking in sequence. This is the pre-test position “, which tests the lights and buttons.

Scrolling through Diagnostic Mode tests:

Tests are selected by using the same method to select cycles. See Diagnostic Mode Tests Table.

To begin, press and hold the cycles button for 2 seconds. The unit will advance to the first test; and flash “ “ on the display.

Press the cycles button to advance to the following test. Press the temp button to go back to the previous test. Test sequence numbers are briefly displayed when each test is selected. The displayed test numbers also correspond to the selector LEDs to the right of the numeric display; beginning with the top LED, following downward.

Exiting Diagnostic Mode:

Hold the power key for 3 sec, when not in “test step Lights/Buttons, or unplug the unit.

A11199902 (1803)

USA 1-877-435-3287

www.electroluxappliances.com

Canada 1-800-265-8352

 

 

 

2

Diagnostic Mode Tests/Demo Mode

 

 

Diagnostic Mode Tests

 

 

 

 

 

 

 

 

 

 

 

 

MODE

TEST NAME

COMPONENTS UNDER TEST

TEST CONDITIONS

DISPLAYED FEEDBACK

 

 

NUMBER

 

 

 

 

 

 

 

 

 

Lights, Buttons

LED indicators

 

Number of key pressed.

 

 

 

 

LCD screen

 

Note: This number may not

 

 

pre-test

 

Button response

 

necessarily correspond to key

 

 

 

 

 

 

number on table on page 1.

 

 

 

Motor, NO HEAT, HUM

Motor relay

Drum rotates for 10 mins

 

 

 

 

ON

Door switch

(if door closed)

 

 

 

 

 

 

 

 

 

 

 

Motor, NTC1 ctrl heater,

Motor relay

Drum rotates for 10 mins

NTC1 reading

 

 

 

HUM ON, NTC1 temp on

Door switch

(if door closed), heater is on until NTC1

 

 

 

 

display

Heater relay

reads 44 C

 

 

 

 

 

NTC1

 

 

 

 

 

 

 

 

 

 

 

 

Motor, NTC2 ctrl heater,

Motor relay

Drum rotates for 10 mins

NTC2 reading

 

 

 

HUM ON, NTC2 temp on

Door switch

(if door closed), heater is on until NTC2

 

 

 

 

display

Heater relay

reads 120 C

 

 

 

 

 

NTC2

 

 

 

 

 

HUM ON, Mist valve ON

Mist triac

Mist on for 10 mins

on units with mist valve;

 

(select models)

 

Valve

(if door closed)

on units without mist valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture sensor circuit

Moisture sensor

Moisture sensor expects to read "open

(open) and (short circuit)

 

 

(400 models)

open and short*

 

circuit" condition and "short circuit"

 

 

 

 

condition*

with nothing if sensor is between

 

 

 

 

 

 

 

 

 

 

Capacitive moisture

Capacitive moisture sensor

Moisture sensor valve read by main

working correctly

 

 

(500 and 600

sensor circuit check

 

control board is inside the predefined

 

 

 

 

threshold

 

 

 

models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error history

The last 3 errors in memory

Errors are most recent first

precedes the 2 character alarm

 

 

 

 

 

(in order of history)

 

 

 

 

 

code, alternating through the alarms

 

 

 

 

 

Note: Pressing temp + select (set)

 

 

 

 

 

 

 

 

 

 

 

keys together clears error history

 

 

 

 

 

 

 

 

 

*The moisture sensor is to the lower left inside the door beside the lint screen. The technician may use metal to short sensor bars. The sensor is touch safe, some materials like dry fingers or a 10k ohm resistor should have no displayed value.

Demo Mode:

The Demo works in two ways: Interactive Mode and Automatic Loop.

The Interactive Mode enables the customer to use the interface without activating the appliance. The machine behavior appears similar to normal operation. Pressing the start button turns on the appliance. The display will count down by the second from the maximum time displayed with its respective cycle. The appliance turns off when it reaches “.

The Automatic Loop will engage if no one interacts with the user interface for 3 minutes, or the start button hasn’t been pressed. The machine will simulate a cycle execution on the display only.

Entering Demo Mode:

1Press power and look for console light up.

2For Rotary Dial Cycle Select Dryer: Within 10 seconds select casual and then simultaneously press and hold temp and select. buttons for 3 seconds. Skip to Step 4.

3For Push Button Cycle Select Dryer: Within 10 seconds select delicates and then simultaneously press and hold temp and select (set) buttons for 3 seconds. Continue to Step 4.

4The message “” will blink 3 times in the center display.

5If “” message does not appear, turn off machine and repeat previous steps.

NOTE

Once Demo Mode is activated, every time the machine is turned on, Demo Mode is automatically recalled; this occurrence is signaled at the start-up by the text “” flashing 3 times in the center display.

Unplugging the unit will not clear Demo Mode. See “Exiting Demo Mode” for more information.

Exiting Demo Mode:

To exit Demo Mode, perform the same sequence used to enter

Demo Mode.

1Press cycles to advance the cycle selection to Delicates.

2Press start; then Press cancel.

3Press power to turn the unit off.

4Press power to turn the unit on. The unit will display will flash “” 3 times on the numeric display.

5Press and hold temp and select (set) simultaneously. The appliance will beep once, the numeric display will cycle off and on. The appliance will then beep with the normal power on sequence.

You may also perform a Factory Default Reset - see below.

Factory Default Reset:

1Press power and look for console light up.

2Wait at least 10 seconds, then simultaneously press and hold the dryness (dry level) and options buttons for 3 seconds. Audible signal will indicate that the settings have been reset.

Recalling Last Error Code:

1Press power and look for console light up.

2Wait at least 10 seconds, then simultaneously press and hold temp and select (set) buttons for 3 seconds.

3The display will show the last error in memory.

4Clear the display and return to normal operation by touching any button or by pressing the power button.

 

 

 

Dryer Error Codes

3

 

 

 

 

 

 

Dryer Error Codes

 

 

 

 

 

 

 

 

 

Error

Error Description

Possible Causes

Display

 

Code

 

 

 

Notification

34

Capacitive sensor values read by main control

Check wiring between main control board and capacitive sensor assembly

Yes

 

 

board is not within the predefined threshold

1.

If wiring is good, replace capacitive sensor assembly

 

 

 

(500 and 600 series only)

2.

If problem is not corrected, replace main control board

 

 

35

Capacitive sensor assembly communication

Check wiring between main control board and capacitive sensor assembly

Yes

 

 

problem with main control board

1.

If wiring is good, replace capacitive sensor assembly

 

 

 

(500 and 600 series only)

2.

If problem is not corrected, replace main control board

 

 

41

Door opened at cycle start

Door open

Door open

 

42

Door closed sensing error

Door switch or wiring or sensing circuit on main board failure

Yes

 

 

 

 

 

 

51

Drum motor relay error

With line safe relay closed, motor sensing detects voltage on motor

No

 

 

 

1.

Motor short circuit to ground (motor or wiring)

 

 

 

 

2.

Electrical noise

 

 

 

 

3.

Line safe relay problem (main board failure)

 

 

 

 

4.

Motor relay open or short

 

 

52

Drum motor start sensing error

Motor relay driven but start sensing not congruent

No

 

 

 

1.

Motor fault

 

 

 

 

2.

Main board fault

 

 

 

 

 

 

 

53

Drum motor centrifugal switch error

Motor driven but sensing not congruent

No

 

 

 

1.

Motor fault

 

 

 

 

2.

Main board fault

 

 

54

Drum motor sensing error

Drum motor relay sensing circuit failure (main board failure)

No

 

61

Heater relay error

1.

Heater disconnected (wiring or connector failure)

No

 

 

 

2.

Heater failure

 

 

 

 

3.

Heater relay failure (open circuit)

 

 

63

Heater short error

1.

Heater sensing circuit failure (main board failure)

No

 

 

 

2.

Heater failure

 

 

64

Heater open error

1.

Heater sensing circuit failure (main board failure)

No

 

 

 

2.

Heater failure

 

 

65

Thermostat open

Heater thermostat trip

No

 

67

Heater sensing error

Heater sensing circuit failure (main board failure)

No

 

71

NTC1 (OPEN) error

1.

NTC open/disconnected

No

 

 

 

2.

Main board fault

 

 

72

NTC1 (SHORTED) error

1.

NTC short

No

 

 

 

2.

Main board fault

 

 

73

NTC2 (OPEN) error

1.

NTC open/disconnected

No

 

 

 

2.

Main board fault

 

 

74

NTC2 (SHORTED) error

1.

NTC short

No

 

 

 

2.

Main board fault

 

 

 

 

 

 

 

91

User Interface communication problem with main

Check wiring between main control board and user interface board

No

 

 

board

1.

If wiring is good, replace user interface board

 

 

 

 

2.

If problem is not corrected, replace main control board

 

 

92

User Interface mother board protocol mismatch

1.

Wiring failure

No

 

 

 

2.

User Interface board failure

 

 

 

 

3.

Main board failure

 

 

93

MCF checksum error

Wrong machine configuration file in main board

Yes

 

94

CCF checksum error

Wrong cycle configuration file in main board

Yes

 

97

Missing program on CTF error

Software problem in main board

Yes

 

9C

User Interface configuration checksum error

Software problem between main board and User Interface board

Yes

 

9E

User Interface touch sensor not working

One or more touch buttons have calibration problems.

No

 

 

 

1.

Electrical noise

 

 

 

 

2.

Humidity/water on UI board

 

 

 

 

3.

UI board defective

 

 

H1/B1

Power supply frequency out of range

1.

Power supply problems

Yes

 

 

 

2. Wrong MCF

 

 

 

 

3.

Main board failure

 

 

H2/B2

Power supply amplitude out of range (too HIGH)

1.

Power supply problems - too HIGH VOLTAGE

Yes

 

 

 

2.

Main board failure

 

 

H3/B3

Power supply amplitude out of range (too LOW)

1.

Power supply problems - too LOW VOLTAGE

Yes

 

 

 

2.

Main board failure

 

 

H4/B4

Line wiring error

Wrong line wiring/connection

Yes

 

HA/BD

Line safe relay short circuit error

Line safe relay problem (main board failure)

No

 

HE/BE

Line safe error

Line safe relay problem (main board failure)

No

 

HF/BF

Line safe sensing error

Line safe sensing circuit failure (main board failure)

No

 

F1

Ventilation blocked error

Air flow duct clogged or blocked, remove debris and clean and check one

Yes

 

 

 

way vent operation

 

 

F6

Safety reset error

Main board fault

No

 

 

 

 

 

 

 

4 Fiche technique de la sécheuse

Ce manuel est destiné aux techniciens de service qualifiés seulement. Les éléments de sécurité dans ce manuel sont dotés d'une étiquette AVERTISSEMENT ou PRUDENCE en fonction du type de risque décrit ci-dessous :

TABLE DES MATIÈRES

 

MISE EN GARDE

Ce symbole vous avertit des situations

Fiche technique de la sécheuse.............................................................

4

pouvant causer des dommages

Essais en mode diagnostic et mode démo

5

 

matériels, des lésions corporelles

 

graves, voire la mort.

Codes d’erreur de la sécheuse

6

 

 

Ce symbole vous avertit des situations

Schéma de câblage

10

PRUDENCE

susceptibles de causer des lésions

 

 

 

 

 

corporelles ou des dommages matériels.

PRUDENCE

Sauf indication contraire, coupez le courant avant d'entreprendre l'entretien.

Cycle avec bouton-poussoir, sélectionnez l'interface utilisateur < dryer > (séchage)

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

Cycle avec cadran rotatif, sélectionnez l'interface utilisateur < dryer > (séchage)

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

1power

mise en marche

2cycle status display indicateur

d’état du cycle

3cycles

sélecteur de cycle

4temp température

5dryness (dry level) niveau de séchage

6time dry (dry time) durée du séchage

7options

8select (set) sélectionner (régler)

9cancel annuler

10start / pause démarrer/pause

Passage au mode Diagnostic :

1.Appuyez sur la touche < power > et validez que la console s'allume.

2.Tournez la bague de sélection des cycles (certains modèles) ou appuyez plusieurs fois sur la touche < cycle > (sur d'autres modèles) pour régler le cycle sur normal.

3.Appuyez sur la touche < start > .

4.Éteignez la machine en appuyant sur touche < power >.

5.Éteignez la machine en appuyant sur touche < power > à nouveau.

6.Dans les 10 secondes, maintenez simultanément les touches < temp > + < select > enfoncées pendant 3 secondes.

7.Le mode Diagnostic est actif lorsque les DEL clignotent en séquence. Il s'agit de la position d'essais préliminaires « » des touches et des voyants.

Défilement des essais en mode Diagnostic :

Les tests sont sélectionnés de la même manière que la sélection des cycles. Voir le tableau Essais en mode Diagnostic.

Pour commencer, maintenez la touche < cycles > enfoncée pendant 2 secondes. L'unité passe au premier essai et « » clignote à l'écran.

Appuyez sur la touche < cycles > pour passer au prochain essai. Appuyez sur la touche < temp > pour revenir à l'essai précédent. Les numéros de séquence des essais s'affichent brièvement lorsque chacun est sélectionné. Les numéros d'essai affichés correspondent également aux voyants de sélection à droite de l'affichage numérique; en commençant par la DEL supérieure, en descendant.

Quitter le mode Diagnostic :

Maintenez la touche < power > enfoncée pendant 3 secondes tandis que le témoin ou la touche d’essai est désactivée

« », ou débranchez l’appareil.

A11199902 (1803)

Aux É.-U. : 1-877-435-3287

www.electroluxappliances.com

Au Canada : 1-800-265-8352

 

 

 

 

Essais en mode diagnostic et mode démo

5

 

 

 

 

 

 

Essais en mode Diagnostic

 

 

 

 

 

 

 

 

 

MODE NUMÉRO

LIBELLÉ DE L'ESSAI

COMPOSANTS SOUS ESSAI

CONDITIONS D’ESSAI

RÉTROACTION AFFICHÉE

 

 

 

 

 

 

Lampes et témoins

Témoins DEL

 

Numéro de la touche enfoncée.

 

lumineux, boutons

Panneau ACL

 

Remarque : Ce numéro

 

essai préliminaire

 

Réponse des boutons

 

peut ne pas correspondre

 

 

 

 

nécessairement au numéro de

 

 

 

 

touche du tableau de la page 1.

 

Moteur, AUCUNE

Relais de moteur

Le tambour tourne pendant 10 minutes

 

 

 

CHALEUR, HUM. ACTIVÉ

Commutateur de la porte

(si la porte est fermée)

 

 

 

Moteur, chauffage ctrl.

Relais de moteur

Le tambour tourne pendant 10 minutes (si la

Lecture NTC1

 

 

NTC1, HUM. ACTIVÉE,

Commutateur de la porte

porte est fermée), le chauffage est en marche

 

 

 

température NTC1 affichée

Relais d’élément chauffant

jusqu'à ce que NTC1 indique 44 °C

 

 

 

 

NTC1

 

 

 

 

Moteur, chauffage ctrl.

Relais de moteur

Le tambour tourne pendant 10 minutes (si la

Lecture NTC2

 

 

NTC2, HUM. ACTIVÉE,

Commutateur de la porte

porte est fermée), le chauffage est en marche

 

 

 

température NTC2 affichée

Relais d’élément chauffant

jusqu'à ce que NTC2 indique 120 °C

 

 

 

 

NTC2

 

 

 

 

HUM. ACTIVÉE, vanne

Triac de brumisation

Brumisation pendant 10 minutes (si la porte est

sur les appareils avec

 

 

de brumisation ACTIVÉE

Vanne

fermée)

vanne de brumisation;

 

(certains modèles)

 

 

 

sur les électroménagers

 

 

 

 

 

avec vanne de brumisation;

 

Circuit du capteur d'humidité

Capteur d'humidité

Le capteur d'humidité s'attend à lire les états

(ouvert) et (court-circuit)

 

ouvert et court-circuit*

 

« circuit ouvert » et « court-circuit » *

(modèles 400)

 

ou rien si le capteur est entre

 

 

 

 

 

 

les deux

 

 

 

 

 

 

 

Vérification de circuit du

Détecteur d'humidité capacitif.

La lecture de la vanne du capteur d'humidité

et fonctionne correctement

(modèles 500 et 600)

capteur d'humidité capacitif

 

par le tableau de commande principal est

 

 

à l'intérieur du seuil prédéfini

 

 

 

 

 

 

 

 

 

Historique des erreurs

Les 3 dernières erreurs

Les erreurs les plus récentes en premier

précède le code d'alarme à

 

 

sauvegardées en mémoire

(par ordre historique)

 

 

2 caractères, alternant entre les

 

 

 

Remarque : Appuyer sur les touches

 

 

 

alarmes

 

 

 

 

< temp > + < select > simultanément efface

 

 

 

 

 

 

 

 

 

l'historique des erreurs

 

 

*Le capteur d'humidité est situé en bas à gauche à l'intérieur de la porte près de la crépine à charpie. Le technicien peut utiliser du métal pour court-circuiter les barres de détection. Le capteur est protégé contre le contact des doigts; certains matériaux comme des doigts secs ou une résistance de 10 kΩ ne doivent pas afficher de valeur.

Mode Démo :

Le mode Démo (démonstration) fonctionne de deux façons : en mode ­interactif et en boucle automatique.

Le Mode interactif permet au client d'utiliser l'interface sans activer l'électroménager. Le comportement de la machine semble normal. Appuyer sur le bouton de démarrage met l'électroménager en marche. L'affichage compte à rebours seconde par seconde à partir de la durée maximale affichée selon son cycle respectif. L'électroménager s'éteint lorsqu'il atteint « ».

Le mode de boucle automatique s'active si personne n'interagit avec ­l'interface utilisateur pendant 3 minutes ou si le bouton de

démarrage n'a pas été enfoncé. La machine simule l'exécution d'un cycle uniquement­ à l'écran.

Pour lancer le mode Demo :

1Appuyez sur la touche < power > et validez que la console s'allume.

2Avec le cadran rotatif, sélectionnez le cycle < dryer > (séchage)­ :

Dans les 10 secondes, sélectionnez <casual> puis appuyez simultanément et maintenez les touches­ < temp > et < select >. enfoncées pendant 3 secondes. Passer à l'étape 4.

3Avec le bouton-poussoir, sélectionnez le cycle < dryer > (séchage): Dans les 10 secondes, sélectionnez < delicates > puis appuyez simultanément et maintenez les touches­ < temp > et < select > ­enfoncées pendant 3 secondes. Passez à l'étape 4.

4Le message « » clignote 3 fois dans l'écran central.

5Si le message « » n'y apparaît pas, éteignez la machine et répétez­ les étapes précédentes.

REMARQUE

Une fois le mode Démo activé, chaque fois que la machine est allumée, le mode Démo est rappelé automatiquement; cette occurrence est

signalée au démarrage par les lettres « » clignotant 3 fois à l'écran

central. Débrancher l'appareil n'efface pas le mode Démo. Pour plus d'informations, voir « Quitter le mode démo ».

Quitter le mode Démo :

Pour quitter le mode Démo, effectuez la même séquence utilisée pouraccéder le mode Démo.

1Appuyez sur la touche < cycles > pour faire avancer la sélection du cycle­ vers Délicats.

2 Appuyez sur < start > ; appuyez ensuite sur <cancel> .

3 Appuyez sur touche < power > pour éteindre ­l'électroménager.

4Appuyez sur< power > pour allumer l'électroménager­. L'affichage numérique de l'appareil clignote « » 3 fois.

5 Appuyez et maintenez les touches < temp > et <select> enfoncées simultanément. L'électroménager émet un bip, l'affichage numérique s'allume et s'éteint. L'appareil émet alors un bip avec la séquence de mise en marche normale.

Vous pouvez également effectuer une réinitialisation aux paramètres par défaut de l'usine. Voir ci-dessous.

Réinitialisation aux paramètres par défaut de l'usine :

1Appuyez sur la touche < power > et validez que la console s'allume.

2Attendez au moins 10 secondes, puis appuyez simultanément sur les touches < dryness > et < options > enfoncées pendant 3 secondes. Le signal sonore indique que les réglages­ ont été réinitialisés.

Rappel du dernier code d'erreur :

1Appuyez sur la touche < power > et validez que la console s'allume.

2Attendez au moins 10 secondes, puis appuyez simultanément sur les touches < temp > et < select > enfoncées pendant 3 secondes.

3L'écran affiche le dernier code d'erreur en mémoire.

4Effacez l'affichage et revenez à un fonctionnement normal en appuyant­ sur n'importe quel bouton ou en appuyant sur la touche­ < power >.

Loading...