Whirlpool AMB 864 Service Manual

4 (1)
SERVICE
Model AMB 864 Version 8528 864 10000 Page
Whirlpool Europe Customer Services
AMB 864
Service Manual
Air Conditioner Split Type AMB 864
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 21.03.2003 Subject to modification Document-No.: 4812 731 15374
21.03.2003 / Page 2 AMB 864 Whirlpool Europe Doc. No: 4812 731 15374 8528 864 10000 Customer Service
Technical data
SERVICE
Factory Code AS-12HR4FN
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 770 mm Width 240 mm Depth 179 mm
Outdoor - unit
Height 755 mm Width 530 mm Depth 252 mm
Weight
Indoor - unit 7.5 kg / net Outdoor - unit 42 kg / net
Cooling Capacity
3513 Watt 12000 BTU / h
Heating Capacity
3630 Watt 12400 BTU / h
Airflow / Evaporator Airvolume
460 m3 / h
Dehumidifying Capacity
1,5 l / h
Noise Level
Indoor - unit 33 - 38 dB(A) Outdoor - unit 51 dB(A)
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz Rated Current (Cooling) 5.8 A Rated Current (Heating) 6.5 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 8.6 Heating 8.87
Compressor (cooling)
Type LG QJ222JT23D Capacity (CECOMAF) 3692 W
Refrigerant
Type R 22 Quantity 840 g
Loading...
+ 3 hidden pages