S E R V I C E |
Whirlpool Europe |
AMB 857 |
Customer Services |
Service Manual
Air Conditioner
Split Type
AMB 857
Model |
AMB 857 |
|
Version |
8528 857 10000 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 |
|
Circuit diagram |
5 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 04.03.2002 |
Subject to modification |
Document-No.: 4812 721 19913 |
|
04.03.2002 / Page 2 |
AMB 857 |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 721 19913 |
8528 857 10000 |
Customer Service |
||
|
|
|
|
|
Technical data
Factory Code |
AS-09HR4FD |
|
Operation type |
|
|
Cooling / Heating |
|
|
Dimensions |
|
|
Indoor - unit |
|
|
Height |
800 |
mm |
Width |
270 |
mm |
Depth |
168 |
mm |
Outdoor - unit |
|
|
Height |
755 |
mm |
Width |
530 |
mm |
Depth |
252 |
mm |
Weight |
|
|
Indoor - unit |
9 |
kg / net |
Outdoor - unit |
40 |
kg / net |
Electrical connection |
|
|
Voltage |
220 - 240 V |
|
Frequency |
50 |
Hz |
Rated Current (Cooling) |
4.1 |
A |
Rated Current (Heating) |
4.2 |
A |
Energy Efficiency Rate (BTU/Watt hr) |
|
|
Cooling |
10.23 |
|
Heating |
10.56 |
|
Compressor (cooling) |
|
|
Type |
PH 160 |
|
Refrigerant |
|
|
Type |
R 22 |
|
Quantity |
860 |
g |
Cooling Capacity |
|
|
|
2635 |
Watt |
|
9000 |
BTU / h |
Heating Capacity |
|
|
|
2782 |
Watt |
|
9500 |
BTU / h |
Airflow / Evaporator Airvolume |
|
|
|
420 |
m3 / h |
Dehumidifying Capacity |
|
|
|
0.9 |
l / h |
Noise Level |
|
|
Indoor - unit |
27 - 33 |
dB(A) |
Outdoor - unit |
50 |
dB(A) |