USER'S GUIDE
Vaisala Humidity and Temperature Probe
HMP60 and HMP110
M211060EN-A
PUBLISHED BY |
|
|
|
Vaisala Oyj |
Phone (int.): |
+358 |
9 8949 1 |
P.O. Box 26 |
Fax: |
+358 |
9 8949 2227 |
FI-00421 Helsinki |
|
|
|
Finland |
|
|
|
Visit our Internet pages at www.vaisala.com
© Vaisala 2010
No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder.
The contents are subject to change without prior notice.
Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
________________________________________________________________________________
Table of Contents |
|
CHAPTER 1 |
|
GENERAL INFORMATION............................................................................ |
7 |
About This Manual ................................................................... |
7 |
Contents of This Manual ....................................................... |
7 |
Version Information ............................................................... |
8 |
Related Manuals ................................................................... |
8 |
Documentation Conventions................................................. |
8 |
Safety......................................................................................... |
9 |
ESD Protection ......................................................................... |
9 |
Recycling ................................................................................ |
10 |
Regulatory Compliances ....................................................... |
10 |
Patent Notice .......................................................................... |
10 |
Trademarks ............................................................................. |
11 |
License Agreement ................................................................ |
11 |
Warranty.................................................................................. |
11 |
CHAPTER 2 |
|
PRODUCT OVERVIEW................................................................................ |
13 |
Introduction to HMP60 and HMP110 .................................... |
13 |
Basic Features and Options.................................................. |
14 |
Filter Options....................................................................... |
15 |
Installation Accessories (Optional) ...................................... |
16 |
Probe Mounting Clamp ....................................................... |
16 |
Probe Mounting Flange....................................................... |
16 |
Loop Power Converter ........................................................ |
17 |
Cables ................................................................................. |
18 |
CHAPTER 3 |
|
INSTALLATION............................................................................................ |
19 |
Dimensions ............................................................................. |
19 |
Mounting the Probe................................................................ |
20 |
Wiring ...................................................................................... |
21 |
Wiring with the Loop Power Converter ............................... |
22 |
Power Supply Requirements............................................... |
23 |
Recommendations ......................................................... |
23 |
CHAPTER 4 |
|
OPERATION................................................................................................. |
25 |
Getting Started ....................................................................... |
25 |
Serial Line Communication................................................... |
25 |
Connecting to the Serial Interface....................................... |
25 |
Installing the Driver for the USB Cable ............................... |
27 |
Terminal Application Settings for Probes in RS-485 Mode. 28 |
VAISALA ________________________________________________________________________ 1
User's Guide ______________________________________________________________________
Terminal Application Settings for Probes in Analog Mode.. |
30 |
List of Serial Commands ....................................................... |
31 |
Device Information and Status.............................................. |
32 |
View Device Information...................................................... |
32 |
View Calibration Information ............................................... |
33 |
View Order Code................................................................. |
33 |
View Serial Number............................................................. |
33 |
View Software Version ........................................................ |
34 |
Serial Line Output Commands.............................................. |
34 |
Start Measurement Output .................................................. |
34 |
Stop Measurement Output .................................................. |
34 |
Output the Measurement Message Once ........................... |
35 |
Configuring Serial Line Operation........................................ |
35 |
Set Serial Line Settings ....................................................... |
35 |
Set Serial Interface Mode.................................................... |
36 |
Set Output Interval............................................................... |
37 |
Set Measurement Filtering .................................................. |
37 |
Set Probe Address .............................................................. |
38 |
Set Serial Interface Delay.................................................... |
38 |
Set Measurement Units....................................................... |
39 |
Calibration Commands .......................................................... |
39 |
Calibrate Humidity Measurement ........................................ |
39 |
Clear Adjustment of RH Measurement................................ |
40 |
Calibrate Temperature Measurement ................................. |
40 |
Clear Adjustment of T Measurement................................... |
41 |
View User Adjustment Parameters ..................................... |
41 |
Other Commands ................................................................... |
42 |
Display Command List ........................................................ |
42 |
Display the Currently Active Errors ..................................... |
42 |
Connect to the Probe in POLL Mode .................................. |
42 |
Close the Connection in POLL Mode.................................. |
42 |
Reset the Probe................................................................... |
43 |
Restore Factory Settings..................................................... |
43 |
CHAPTER 5 |
|
MAINTENANCE............................................................................................ |
45 |
Periodic Maintenance............................................................. |
45 |
Cleaning .............................................................................. |
45 |
Changing the Filter .............................................................. |
46 |
Calibration Procedure ............................................................ |
46 |
Adjustment Procedure (HMP110).......................................... |
47 |
One-point Adjustment of RH Measurement (HMP110)....... |
47 |
Two-point Adjustment of RH Measurement (HMP110)....... |
48 |
One-point Adjustment of T Measurement (HMP110).......... |
50 |
Repair Maintenance................................................................ |
52 |
Changing the INTERCAP Sensor (HMP60)........................ |
52 |
Changing the HUMICAP 180R Sensor (HMP110).............. |
53 |
CHAPTER 6 |
|
TROUBLESHOOTING.................................................................................. |
55 |
Solving Typical Problems...................................................... |
55 |
Technical Support .................................................................. |
56 |
2 ___________________________________________________________________ M211060EN-A
________________________________________________________________________________
CHAPTER 7 |
|
TECHNICAL DATA ...................................................................................... |
57 |
Specifications ......................................................................... |
57 |
Performance (HMP60) ........................................................ |
57 |
Relative Humidity ........................................................... |
57 |
Temperature................................................................... |
57 |
Dewpoint ........................................................................ |
57 |
Performance (HMP110) ...................................................... |
58 |
Relative Humidity ........................................................... |
58 |
Temperature................................................................... |
58 |
Dewpoint ........................................................................ |
58 |
Operating Environment ....................................................... |
59 |
Inputs and Outputs.............................................................. |
59 |
Mechanics ........................................................................... |
59 |
Options and Accessories ...................................................... |
60 |
VAISALA ________________________________________________________________________ 3
User's Guide ______________________________________________________________________
This page intentionally left blank.
4 ___________________________________________________________________ M211060EN-A
________________________________________________________________________________
List of Figures |
|
|
Figure 1 |
HMP60 (left) and HMP110 (right)............................................. |
13 |
Figure 2 |
Filter Options ............................................................................ |
15 |
Figure 3 |
Probe Mounting Clamp in Use ................................................. |
16 |
Figure 4 |
Probe Mounting Flange............................................................ |
16 |
Figure 5 |
Loop Power Converter ............................................................. |
17 |
Figure 6 |
Cable with Threaded Connector .............................................. |
18 |
Figure 7 |
USB Serial Interface Cable ...................................................... |
18 |
Figure 8 |
HMP60 and HMP110 Dimensions ........................................... |
19 |
Figure 9 |
Installation with Plastic M12 Nuts, Dimensions........................ |
19 |
Figure 10 |
Wiring of Analog Output ........................................................... |
21 |
Figure 11 |
Wiring of Digital Output ............................................................ |
21 |
Figure 12 |
Wiring with the Loop Power Converter Module........................ |
22 |
Figure 13 |
PuTTY Terminal Application .................................................... |
29 |
Figure 14 |
Changing the Sensor................................................................ |
52 |
List of Tables |
|
|
Table 1 |
Manual Revisions ....................................................................... |
8 |
Table 2 |
Related Manuals ........................................................................ |
8 |
Table 3 |
Quantities Measured by the HMP60 and HMP110 .................. |
14 |
Table 4 |
Filter Properties ........................................................................ |
15 |
Table 5 |
Pinout of the Probe Connector................................................. |
21 |
Table 6 |
Default Serial Communication Settings.................................... |
26 |
Table 7 |
List of Serial Commands .......................................................... |
31 |
Table 8 |
Additional Commands for Probes with RS-485 Output............ |
31 |
Table 9 |
Troubleshooting Table.............................................................. |
55 |
Table 10 |
HMP60 Options and Accessories ............................................ |
60 |
Table 11 |
HMP110 Options and Accessories .......................................... |
60 |
VAISALA ________________________________________________________________________ 5
User's Guide ______________________________________________________________________
This page intentionally left blank.
6 ___________________________________________________________________ M211060EN-A
Chapter 1 ________________________________________________________ General Information
CHAPTER 1
This chapter provides general notes for the manual and the product.
This manual provides information for installing, operating, and maintaining Vaisala Humidity and Temperature Probe HMP60 and HMP110.
This manual consists of the following chapters:
-Chapter 1, General Information, provides general notes for the manual and the product.
-Chapter 2, Product Overview, introduces the product features and options.
-Chapter 3, Installation, provides you with information that is intended to help you install HMP60 and HMP110.
-Chapter 4, Operation, contains information that is needed to operate HMP60 and HMP110.
-Chapter 5, Maintenance, provides information that is needed in basic maintenance of HMP60 and HMP110.
-Chapter 6, Troubleshooting, describes common problems, their probable causes and remedies, and contact information for technical support.
-Chapter 7, Technical Data, provides the technical data of the HMP60 and HMP110.
VAISALA ________________________________________________________________________ 7
User's Guide ______________________________________________________________________
Table 1 |
Manual Revisions |
|
|
|
|
Manual Code |
|
Description |
M211060EN-A |
|
March 2010. This manual. First version. |
|
|
Table 2 |
Related Manuals |
|
|
|
|
|
|
|
|
|
|
|
|
Manual Code |
|
Manual Name |
|
|
|
|
M211059EN |
|
HMP60 and HMP110 Quick Guide |
|
|
|
|
M211106EN |
|
Loop Power Converter Quick Reference guide |
|
|
|
|
Documentation Conventions |
|
|
||
|
|
Throughout the manual, important safety considerations are highlighted |
|
|
||
|
|
as follows: |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
||
|
WARNING |
Warning alerts you to a serious hazard. If you do not read and follow |
|
|
||
|
|
instructions very carefully at this point, there is a risk of injury or even |
|
|
death.
CAUTION |
Caution warns you of a potential hazard. If you do not read and follow |
|
instructions carefully at this point, the product could be damaged or |
|
important data could be lost. |
|
|
NOTE |
Note highlights important information on using the product. |
|
|
8 ___________________________________________________________________ M211060EN-A
Chapter 1 ________________________________________________________ General Information
|
|
|
The product delivered to you has been tested for safety and approved as |
|
|
|
shipped from the factory. Note the following precautions: |
|
|
|
|
|
|
WARNING |
Ground the product, and verify outdoor installation grounding |
|
|
|
periodically to minimize shock hazard. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION |
Do not modify the unit. Improper modification can damage the product |
|
|
|
or lead to malfunction. |
|
|
|
|
Electrostatic Discharge (ESD) can cause immediate or latent damage to electronic circuits. Vaisala products are adequately protected against ESD for their intended use. It is possible to damage the product, however, by delivering electrostatic discharges when touching, removing, or inserting any objects inside the equipment housing.
To make sure you are not delivering high static voltages yourself:
-Handle ESD sensitive components on a properly grounded and protected ESD workbench.
-When an ESD workbench is not available, ground yourself to the equipment chassis with a wrist strap and a resistive connection cord.
-If you are unable to take either of the above precautions, touch a conductive part of the equipment chassis with your other hand before touching ESD sensitive components.
-Always hold component boards by the edges and avoid touching the component contacts.
VAISALA ________________________________________________________________________ 9
User's Guide ______________________________________________________________________
Recycle all applicable material.
Dispose of batteries and the unit according to statutory regulations. Do not dispose of with regular household refuse.
The HMP60 and HMP110 are in conformity with the provisions of the following EU directive(s):
ROHS Directive (2002/95/EEC)
WEEE Directive (2002/96/EEC)
EMC Directive (2004/108/EC)
The electromagnetic compatibility of the HMP60 and HMP110 has been tested according to the following product family standards:
EN 61326-1:2006 Electrical equipment for measurement, control and laboratory use - EMC requirements - Basic immunity test requirements.
EN 55022:2006 + Am 1:2007 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement.
Class B.
The HMP60 and HMP110 are protected by the following patents and patent applications and their corresponding national rights:
Finnish patent 98861, French patent 6650303, German patent 69418174, Japanese patent 3585973, UK patent 0665303, U.S. patent 5607564.
10 __________________________________________________________________ M211060EN-A
Chapter 1 ________________________________________________________ General Information
Vaisala INTERCAP® and Vaisala HUMICAP® are registered trademarks of Vaisala Oyj.
Windows® is a registered trademark of Microsoft Corporation in the
United States and/or other countries.
All rights to any software are held by Vaisala or third parties. The customer is allowed to use the software only to the extent that is provided by the applicable supply contract or Software License Agreement.
For certain products Vaisala normally gives a limited one-year warranty. Visit our Internet pages for more information and our standard warranty terms and conditions: www.vaisala.com/services/warranty.html.
Please observe that any such warranty may not be valid in case of damage due to normal wear and tear, exceptional operating conditions, negligent handling or installation, or unauthorized modifications. Please see the applicable supply contract or Conditions of Sale for details of the warranty for each product.
VAISALA _______________________________________________________________________ 11
User's Guide ______________________________________________________________________
This page intentionally left blank.
12 __________________________________________________________________ M211060EN-A
Chapter 2 __________________________________________________________ Product Overview
CHAPTER 2
This chapter introduces the product features and options.
Vaisala Humidity and Temperature Probes HMP60 and HMP110 are simple and cost-effective humidity transmitters suitable for volume applications, integration into other manufacturers’ equipment, incubators, glove boxes, greenhouses, fermentation chambers, and data loggers.
HMP60 uses the interchangeable Vaisala INTERCAP® sensor. No recalibration is required after sensor replacement.
HMP110 uses the Vaisala HUMICAP 180R® sensor for increased accuracy. The HMP110 requires calibration after sensor replacement. This can be done on the serial line using the optional Vaisala USB cable.
0912-101
Figure 1 HMP60 (left) and HMP110 (right)
VAISALA _______________________________________________________________________ 13
User's Guide ______________________________________________________________________
Table 3 Quantities Measured by the HMP60 and HMP110
Quantity |
Abbreviation |
Metric Unit |
Non Metric Unit |
Relative humidity |
RH |
%RH |
%RH |
Dewpoint/Frostpoint |
Td/f |
ºC |
ºF |
temperature* |
|
|
|
Temperature |
T |
ºC |
ºF |
* When the dewpoint is below 0 °C, the probe outputs frostpoint for Td
-Analog output mode: two analog output channels, selectable from 0 ... 1 V / 0 ... 2.5 V / 0 ... 5 V / 1 ... 5 V
-RS-485 output mode
-Small size
-Low power consumption
-IP65 aluminum body
-Options and accessories:
-Filter options: plastic grid filter, membrane filter, and stainless steel sintered filter
-One channel loop power converter 4 ... 20 mA (separate module, compatible with humidity accuracy only)
-Shielded 0.3 m and 3.0 m connection cables with threaded connector for probe connection, open end wires on the other end
-Plastic M12 installation nuts
14 __________________________________________________________________ M211060EN-A
Chapter 2 __________________________________________________________ Product Overview
The available filters for HMP60 and HMP110 are shown in Figure 2 below. For order codes, see section Options and Accessories on page 60.
|
|
|
|
1001-008 |
Figure 2 |
Filter Options |
|
|
|
Table 4 |
Filter Properties |
|
|
|
|
|
|
|
|
No. |
Filter |
|
Diameter |
Pore Size |
1 |
Plastic grid filter (fastest response time) |
12 mm |
- |
|
2 |
Membrane filter |
12 mm |
0.2 µm |
|
3 |
Stainless steel sintered filter |
12 mm |
38 µm |
VAISALA _______________________________________________________________________ 15
User's Guide ______________________________________________________________________
The optional mounting clamp makes it easy to install the probe on the wall of the measurement environment. The probe can be detached for calibration simply by loosening the lower screw.
1001-138
Figure 3 Probe Mounting Clamp in Use
The probe mounting flange is a silicone flange can be used to hold the probe in a through-wall installation. The flange is a general purpose mounting accessory for Ø 12mm probes, and comes with a sealing plug for coaxial cables that is not needed when the flange is used with HMP60 and HMP110.
0911-109
Figure 4 Probe Mounting Flange
16 __________________________________________________________________ M211060EN-A
Chapter 2 __________________________________________________________ Product Overview
The loop power converter is an open frame module that converts one 0 ... 2.5 VDC voltage output to a 4 ... 20 mA current output. To use the loop power converter module, the probe:
-must be in the analog output mode
-the desired quantity must be on channel 1
-channel 1 must be scaled to 0 ... 2.5 V
Wiring instructions are provided in section Wiring with the Loop Power Converter on page 22.
1001-001
Figure 5 Loop Power Converter
VAISALA _______________________________________________________________________ 17
User's Guide ______________________________________________________________________
The probe cables have a standard M8 connector. Also other compatible M8 series cables can be used.
0910-135
Figure 6 Cable with Threaded Connector
The USB Serial Interface Cable uses a snap-on connector. The USB cable is intended for maintenance purposes only, not permanent installation.
0809-002
Figure 7 USB Serial Interface Cable
18 __________________________________________________________________ M211060EN-A