MCO-80IC
Reach-In CO2
Incubator
Features:
•The industry’s most complete cell culture solution for large volume applications.
•Exceptionally low CO2 consumption with fast CO2 recovery following door openings.
Panasonic… the new name for SANYO
www.panasonic.com/biomedical
MCO-80IC
Reach-In CO2 Incubator
Panasonic’s large capacity, reach-in CO2 incubator has the capacity and flexibility to grow with your culturing needs while providing a precise and repeatable temperature, humidity and CO2 environment.
The MCO-80IC is ideal for culturing large volumes of biological samples, performing short-term studies, and working with large volume cell culture apparatus. It includes Panasonic’s exclusive incubator technologies such as inCu-saFe® interiors, UV decontamination option, infrared (IR) CO2 sensor with P.I.D. control, and features exceptionally low CO2 gas consumption.
Superior CO2 and
Temperature Control
•IR CO2 sensor with P.I.D. microprocessor control and forced air circulation
system delivers fast CO2 recovery characteristics.
•Exceptionally low CO2 gas consumption rates, less than half of similar competitive units.
•P.I.D. temperature control with deviation of ±0.1°C.
|
|
|
|
Heater On |
||||||
|
|
|
|
Indicator |
||||||
|
|
|
|
|||||||
UV Decontamination – |
|
|
|
CO2 Inject Indicator |
||||||
|
|
|
|
|
Setpoint – Set Temperature and CO2 |
|||||
Light Indicator |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Calibration - Calibrate chamber |
Open Door Indicator |
|
|
|
|
|
|
|
temperature and CO2 |
||
|
|
|
|
|
|
|
|
|||
Water Reservoir |
|
|
|
|
|
|
|
|
Optional Built-in CO2 |
|
|
|
|
|
|
|
|
|
Tank Switchover System |
||
Level Indicator |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CO2 Display
Secondary Over
Temp. Indicator Alarm, Buzzer
Silence
Scroll Programming Buttons
Over Temp. Safety
Shut off Adjustment
Temperature Display
High Humidity Mode Indicator
Temperature Recovery
37°C
36°C
35°C
34°C
33°C
10 min. |
20 min. |
Panasonic MCO-80IC
Recovery after a 30 second door opening for the Panasonic MCO-80IC.
CO2 recovery after a 60 second door opening |
CO2 recovery after a 60 second door opening |
for the Panasonic MCO-80IC |
for the competitor |
5%
4%
3%
2%
1%
10 min. |
20 min. |
Panasonic MCO-80IC
5% |
|
4% |
|
3% |
|
2% |
|
1% |
|
10 min. |
20 min. |
Competitor |
|
Faster CO2 Recovery and lower CO2 Consumption after 60 second door opening.
2 MCO-80IC Reach-In Incubator www.panasonic.com/biomedical