SPLIT TYPE AIR CONDITIONER
MODEL
RAS-25YHA3/RAC-25YHA3
INDOOR UNIT/OUTDOOR UNIT
INDOOR UNIT
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
OUTDOOR UNIT
RAC-25YHA3
RAS-35YHA4 /RAC-35YHA4
RAC-35YHA4
RAS-25YHA3 RAS-35YHA4
– 2 –
SAFETY PRECAUTION
• Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
• Pay special attention to signs of “
Warning ” and “ Caution ”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
• The signs indicate the following meanings. (The following are examples of signs.)
• Please keep this manual after reading.
This sign in the figure indicates prohibition. Indicates the instructions that must be followed.
WARNING
CAUTION
• Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
• Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
• Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
• Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.
• A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
• Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it. Piping shall be suitable supported with a maximum spacing of 1m between the supports.
• Please ensure smooth flow of water when installing the drain hose. If any failure is found in the drain path, water drops from the indoor and outdoor units, causing wet household effects.
• Make sure that a single phase 240V power source is used. The use of other power sources may cause electrical components to overheat and lead to fire.
PROHIBITION
CONNECT EARTH LINE
PROHIBITION
PROHIBITION
• Should abnormal situation arise (like burning smell), please stop operating the unit and remove plug from the socket or turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
• Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
• Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
WARNING
PRECAUTIONS DURING INSTALLATION
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
“OFF”
PROHIBITION
• Avoid an extended period of direct air flow for your health.
• Do not connect the power calbe with an extension cable or do not plug too many leads of the other electric appliance into the socket where this cable is plugged. In addition, wire the cable with some allowances to prevent the cable from stretching. Not doing so will cause an electrical shock, heat generation or fire.
PROHIBITION
• Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause danger.
• Do not bundle the power cable, pull it, put something on it, heat it, process it, or put it between things. Breakage of the power cable may result. Use of a damaged cable may cause an electrical shock or a fire.
PROHIBITION
PROHIBITION
– 3 –
HSILGNE
WARNING
PRECAUTIONS DURING OPERATION
• Do not use any conductor as fuse wire, this could cause fatal accident.
PROHIBITION
• During thunder storm, disconnect the plug top or turn off the circuit breaker.
• Spray cans and other combustibles should not be located within a meter of the air outlets of both indoor and outdoor units. As a spray can’s internal pressure can be increased by hot air, a rupture may result.
“OFF”
CAUTION
PROHIBITION
• The product shall be operated under the manufacturer specification and not for any other intended use.
PROHIBITION
DON’T WET
• Do not attempt to operate the unit with wet hands, this could cause fatal accident.
STRICTLY OBSERVE
PRECAUTIONS
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
• When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
• Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
• Do not wash the unit with water or place a water container such as a vase on the indoor unit. Electrical leakage could be present and cause electric shock.
• Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
• Do not place plants or animals directly under the air flow as it is bad for the plants or animals.
• Do not climb on the outdoor unit or put objects on it.
PROHIBITION
PROHIBITION
PROHIBITION
DON’T TOUCH
DON’T TOUCH
• When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automati­cally for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
• If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
• This appliance especially indoor unit cleaning must be performed by authorized personnel only. Consult your sales agent. Using a commercially available detergent or similar can damage the plastic parts or clog the drain pipe, causing water to drip with potential electric shock hazard.
• Do not touch the air outlet, bottom surface and aluminum fin of the outdoor unit. You may get hurt.
• Do not touch the refrigerant pipe and connecting valve. Burns may result.
• This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use this appliance safely.
• Young children should be supervised to ensure that they do not play with the appliance.
– 4 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter To prevent dust from coming into the indoor unit.
(Refer page 16)
Front panel
Indoor unit indicators Light indicator showing the operating condition.
(Refer page 5)
Horizontal deflector Vertical deflector (Air Outlet)
(Refer page 15)
Remote controller Send out operation signal to the indoor unit. So as to operate the whole unit.
(Refer page 6)
MODEL NAME AND DIMENSIONS
About the outdoor unit:
• When “Stop” is selected during operation of the indoor unit, the fan of the outdoor unit continues turning for 10 to 60 seconds to cool the electric parts down.
• In heating operation, condensate or water due to defrosting will flow. Do not cover the drain port of the outdoor unit because such water may freeze in the chilly area.
• When the outdoor unit is hung on the ceiling, install the bush and drain pipe on the drain port and drain water.
MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm)
780 280 220
750 548 288RAC-25YHA3
Air outlet When “heating” operation is performed, cool air blows and when “cooling” or “dehumidifying” operation is performed, warm air blows.
Drain hose Drains the dehumidified water from the indoor unit to the outdoor during “cooling” or “dehumidifying” operation.
Piping and Wiring
Air inlets (Rear and left sides)
Drain port
(Bottom)
Earth terminal
(Lower section of the side)
OUTDOOR UNIT
RAS-25YHA3\
RAC-35YHA4
RAS-35YHA4
– 5 –
ENGLISH
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT INDICATIONS
TIMER LAMP (Orange) This lamp lights when the timer is working.
FILTER LAMP (Green) When the device is operated for a total of about 200 hours, the FILTER lamp lights indicates that it is time to clean the filter.The lamp goes out when the “
(AUTO SWING)” button is pressed while the
operation is stopped. OPERATION LAMP (Yellow) This lamp lights during operation. The OPERATION LAMP flashes in the following cases during heating. (1) During preheating
For about 2-3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchanger of the outdoor unit, for 5-10 minutes each time.
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work. This temporary operation will be at the most recent setting made. (The unit will immediately go into automatic operation once power is switched on.)
CAUTION
Turn off the circuit breaker or pull out the power plug if the unit is not be operated for a long period.
If the power stays on and the unit is not operated, power is slightly consumed in the control circuit. The power is saved by turning off the power switch (or the circuit breaker when the power is supplied from the outdoor unit).
Frame
Attaching the air purifying filters (Accessories) to the filter frame.
• Attach the air cleansing and deodorizing filters to the frame by gently compress its both sides and release after insertion into filter frame.
• The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying filters are used.
• Air purifying filters can be used for about 1 year. When you want to renew it, please ask your sales agent. Optional air cleansing and deodorizing filters(SPX-CFH15).
– 6 –
Signal emitting window/transmission sign Point this window toward the indoor unit when controlling it.
The transmission sign blinks when a signal is sent. Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
START/STOP button Press this button to start operation. Press it again to stop operation. AUTO SWING button Controls the angle of the horizontal air deflector. FAN SPEED selector This determines the fan speed. Every time you press this button, the intensity of
circulation will change from
(AUTO) to (HI) to (MED) to (LOW) to (SILENT). (This button allows selecting the optimal or preferred fan speed for each operation mode.)
SLEEP button Use this button to set the sleep timer.
TEMPERATURE buttons Use these buttons to raise or lower the temperature setting. (Keep pressed, and
the value will change more quickly.) TIME button
Use this button to set and check the time and date. RESET button
Press this button after the batteries are replaced or when some irregular operation is found.
FUNCTION selector Use this button to select the operating mode. Every time you press it, the mode
will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to (COOL) and to (FAN) cyclically.
FAN SPEED selector AUTO SWING button TIMER control
Use these buttons to set the timer. OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time. RESERVE button Time setting reservation. CANCEL button Cancel time reservation.
NAMES AND FUNCTIONS OF EACH PART
REMOTE CONTROLLER
• This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter, in some cases, the control signal may not be received. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
• Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission capability.
• After new batteries are inserted into the remote controller, the unit will initially require approximately 10 seconds to respond to commands and operate.
Precautions for Use
• Do not put the remote controller in the following places.
• In direct sunlight
• In the vicinity of a heater.
• Handle the remote controller carefully. Do not drop it on the floor, and protect it from water.
• Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again). This is to protect the device and does not indicate a failure.
• If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection.
– 7 –
HSILGNE
VARIOUS FUNCTIONS
Auto Restart Control
• If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction. (As the operation is not stopped by remote controller.)
• If you intend not to continue the operation when the power is resumed, switch off the power supply. When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction. Note: 1. If you do not require Auto Restart Control, please consult your sales agent.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT or COOL depending on the initial room temperature. The selected mode of operation will change when the room temperature varies.
Press the FUNCTION selector so that the display indicates the
(AUTO) mode of operation.
• When AUTO has been selected, the device will automatically determine the mode of operation, HEAT or COOL depending on the current room temperature.
• When AUTO is first selected, the device will determine the current room temperature and select the proper operation mode accordingly.
• When the air conditioner has adjusted the room's temperature to the near preset temperature, it will begin to monitor operation. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (heating or cooling) to adjust the temperature to the preset temperature. The monitoring operation range is
+
3°C relative to the preset temperature.
• If the mode automatically selected by the unit is not satisfactory, manually change the mode setting (heat, dehumidify, cool or fan).
1
Press the (START/STOP) button. Operation starts with a beep. Press the button again to stop operation.
Press the (FAN SPEED) button to select AUTO, LOW and SILENT.
As the settings are stored in memory in the remote controller, you only have to press the
(START/STOP) button next time.
You can raise or lower the temperature setting as necessary by maximum of 3°C.
Press the temperature button and the temperature setting will change by 1°C each time.
• The preset temperature and the actual room temperature may vary somewhat depending on conditions.
START
STOP
– 8 –
Press the (START/STOP) button. Heating operation starts with a beep. Press the button again to stop operation.
START
STOP
HEATING OPERATION
• Use the device for heating when the outdoor temperature is under 21°C. When it is too warm (over 21°C), the heating function may not work in order to protect the device.
• In order to keep reliability of the device, please use this device above -15°C of the outdoor temperature.
Press the FUNCTION selector so that the display indicates
(HEAT).
1
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO) : The fan speed changes automatically according
to the temperature of the air which blows out.
(HI) : Economical as the room will become warm
quickly. But you may feel a chill at the beginning.
(MED) : Quiet.
(LOW) : More quiet.
(SILENT) : Silent.
2
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).
The temperature setting and the actual room temperature may vary somewhat depending on conditions.
3
As the settings are stored in memory in the remote controller, you only have to press the
(START/STOP) button next time.
Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit, for 5~10 minutes each time.
During defrosting operation, the operation lamp blinks in cycle of 3 seconds on and 0.5 second off.
The maximum time for defrosting is 20 minutes.
(If the piping length used is longer than usual, frost will likely to form.)