HITACHI RAS-35FH6 User Manual

5 (2)

ENGLISH

SPLIT TYPE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

MODEL

RAS-18FH6/RAC-18YH6

RAS-25FH6/RAC-25YH6

RAS-35FH6/RAC-35YH6

OUTDOOR UNIT

RAC-18YH6 RAC-25YH6

RAC-35YH6

INDOOR UNIT

RAS-18FH6 RAS-25FH6 RAS-35FH6

Instruction manual Page 1~20 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.

Bedlenungsanleitung Seite 21~40 Bitte lesen Sie diese Bedienungsanleitung aufmerksam durch, um durch richtige Bedienung jahrelangen und störungsfreien Betrieb zu gewährleisten.

Mode d’emploi Page 41~60

Des performances optimales et un fonctionnement à long terme seront assurés en appliquant les présentes instructions après avoir entièrement lu ce mode d’emploi.

Manuale di istruzioni Pag. 61~80

Per garantire la migliore prestazione e la più lunga durataleggere attentamente e al completo le seguanti istruzioni

Manual de instrucciones Página 81~100 Para obtener el mejor funcionamiento y asegurar años de uso libre de problemas, lea cuidadosamente este manual de instrucciones.

Manual de instruções Página 101~120 A fim de obter um bom funcionamento e de garantir uma utilização sem falhas durante muitos anos, é favor ler este manual de instruções completamente.

√‰ËÁ›Â˜ ¯Ú‹Û˘ ™ВП›‰· 121~140 °И· ЩЛУ О·П‡ЩВЪЛ · fi‰ФЫЛ ЩФ˘ ОПИМ·ЩИЫЩИОФ‡ О·И БИ· ЩЛУ М·ОЪФ ЪfiıВЫМЛ ¯Ъ‹ЫЛ ЩФ˘ ¯ˆЪ›˜ЪФ‚П‹М·Щ·, ‰И·‚¿ЫЩВ ЪФЫВОЩИО¿ ·˘Щ¤˜ ЩИ˜ Ф‰ЛБ›В˜ ¯Ъ‹ЫЛ˜.

– 1 –

SAFETY PRECAUTION

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.

The signs indicate the following meanings. (The following are examples of signs.)

This sign in the figure indicates prohibition.

Indicates the instructions that must be followed.

 

 

• Please keep this manual after reading.

 

 

PRECAUTIONS DURING INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not reconstruct the unit.

 

 

 

 

 

Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by

 

 

 

 

 

yourself.

PROHIBITION

 

Please ask your sales agent or qualified technician for the installation of your

 

 

 

 

 

unit.

 

 

 

WARNING

 

Water leakage, short circuit or fire may occur if you install the unit by yourself.

 

 

 

Please use earth line.

 

 

 

 

 

 

 

 

 

Do not place the earth line near water or gas pipes, lightning-conductor, or the

 

 

 

 

 

earth line of telephone. Improper installation of earth line may cause electric

 

 

 

 

 

 

 

 

CONNECT EARTH LINE

 

 

shock.

 

 

 

 

Be sure to use the specified piping set for R410A. Otherwise, this may result in

 

 

 

 

 

broken copper pipes or faults.

 

 

 

 

A circuit breaker should be installed depending on the mounting site of the unit.

 

 

 

 

 

Without a circuit breaker, the danger of electric shock exists.

 

 

 

 

 

Do not install the unit near a location where there is flammable gas.

 

 

 

 

 

The outdoor unit may catch fire if flammable gas leaks around it. Piping shall be

PROHIBITION

 

 

suitable supported with a maximum spacing of 1m between the supports.

 

 

 

CAUTION

Please ensure smooth flow of water when installing the drain hose. If any failure

 

 

 

 

 

is found in the drain path, water drops from the indoor and outdoor units, causing

 

 

 

 

 

wet household effects.

 

 

 

Make sure that a single phase 230V power source is used.

The use of other power sources may cause electrical components to overheat

and lead to fire.

PROHIBITION

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

• Should abnormal situation arise (like burning smell), please stop operating the unit and remove plug from the socket or turn off the circuit breaker. Contact your

agent. Fault, short circuit or fire may occur if you continue to operate the unit “OFF” under abnormal situation.

Please contact your agent for maintenance.

Improper self maintenance may cause electric shock and fire.

Please contact your agent if you need to remove and reinstall the unit.

Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.

• Avoid an extended period of direct air flow for your health.

 

 

PROHIBITION

WARNING

Do not connect the power calbe with an extension cable or do not plug too many

 

 

leads of the other electric appliance into the socket where this cable is plugged.

 

 

In addition, wire the cable with some allowances to prevent the cable from stretching.

 

 

Not doing so will cause an electrical shock, heat generation or fire.

PROHIBITION

Do not bundle the power cable, pull it, put something on it, heat it, process it, or

 

 

put it between things. Breakage of the power cable may result.

 

 

Use of a damaged cable may cause an electrical shock or a fire.

PROHIBITION

 

 

 

• Do not put objects like thin rods into the panel of blower and suction side

 

because the high-speed fan inside may cause danger.

 

 

PROHIBITION

 

– 2 –

PRECAUTIONS DURING OPERATION

• Do not use any conductor as fuse wire, this could cause fatal accident.

PROHIBITION

• During thunder storm, disconnect the plug top or turn off the circuit breaker.

WARNING “OFF”

• Spray cans and other combustibles should not be located within a meter of the air

 

outlets of both indoor and outdoor units.

 

As a spray can’s internal pressure can be increased by hot air, a rupture may result.

PROHIBITION

The product shall be operated under the manufacturer specification and not for any other intended use.

PROHIBITION

• Do not attempt to operate the unit with wet hands, this could cause fatal accident.

DON’T WET

When operating the unit with burning equipments, regularly ventilate

 

 

the room to avoid oxygen insufficiency.

STRICTLY OBSERVE

 

 

 

PRECAUTIONS

 

Do not direct the cool air coming out from the air-conditioner panel to

 

PROHIBITION

face household heating apparatus as this may affect the working of

 

apparatus such as the electric kettle, oven etc.

 

Please ensure that outdoor mounting frame is always stable, firm and

 

 

without defect. If not, the outdoor unit may collapse and cause danger.

PROHIBITION

 

 

 

 

Do not wash the unit with water or place a water container such as a

 

 

vase on the indoor unit.

 

 

PROHIBITION

Electrical leakage could be present and cause electric shock.

Do not place plants or animals directly under the air flow as it is bad for the plants or

 

animals.

 

PROHIBITION

 

 

 

• Do not climb on the outdoor unit or put objects on it.

 

PROHIBITION

 

CAUTION

 

• When operating the unit with the door and windows opened, (the room humidity

 

is always above 80%) and with the air deflector facing down or moving automati-

 

cally for a long period of time, water will condense on the air deflector and drips

PROHIBITION

down occasionally. This will wet your furniture. Therefore, do not operate under

 

such condition for a long time.

 

If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and

PROHIBITION etc.), the preset room temperature cannot be achieved.

• This appliance especially indoor unit cleaning must be performed by authorized

personnel only. Consult your sales agent.

 

Using a commercially available detergent or similar can damage the plastic parts

PROHIBITION

or clog the drain pipe, causing water to drip with potential electric shock hazard.

 

• Do not touch the air outlet, bottom surface and aluminum fin of the outdoor unit.

You may get hurt.

DON’T TOUCH

• Do not touch the refrigerant pipe and connecting valve. Burns may result.

DON’T TOUCH

This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use this appliance safely.

Young children should be supervised to ensure that they do not play with the appliance.

3 –

ENGLISH

NAMES AND FUNCTIONS OF EACH PART

INDOOR UNIT

 

Air filter

 

 

To prevent dust from coming into the indoor unit.

 

(Refer page 16)

 

Front panel

 

 

Indoor unit indicators

 

Light indicator showing the operating condition.

 

(Refer page 5)

 

 

Horizontal deflector Vertical deflector

 

(Air Outlet)

 

 

(Refer page 15)

 

Remote controller

 

Send out operation signal to the indoor unit. So as

 

to operate the whole unit.

 

(Refer page 6)

 

OUTDOOR UNIT

 

RAC-18YH6

Air outlet

Drain hose

When “heating” operation is

RAC-25YH6

Drains the dehumidified water from the indoor unit to the

performed, cool air blows and

outdoor during “cooling” or “dehumidifying” operation.

 

when “cooling” or “dehumidifying”

 

Piping and Wiring

 

operation is performed, warm air

 

blows.

Air inlets (Rear and left sides)

 

Drain port

 

 

 

 

 

 

(Bottom)

Earth terminal

 

 

 

 

(Lower section of the side)

 

 

 

RAC-35YH6

Air outlet

 

 

Drain hose

 

When “heating” operation is

Drains the dehumidified water from the indoor unit to the

 

 

performed, cool air blows and

outdoor during “cooling” or “dehumidifying” operation.

 

when “cooling” or “dehumidifying”

Piping and Wiring

 

 

operation is performed, warm air

 

 

blows.

 

 

Air inlets (Rear and left sides)

 

 

 

 

About the outdoor unit:

 

 

 

 

 

When “Stop” is selected during operation

 

 

 

 

 

of the indoor unit, the fan of the outdoor

 

 

 

 

 

unit continues turning for 10 to 60

 

 

 

 

 

seconds to cool the electric parts down.

 

 

 

 

• In heating operation, condensate or

 

 

 

 

 

water due to defrosting will flow.

 

Drain port

 

 

 

Do not cover the drain port of the outdoor

 

 

 

 

unit because such water may freeze in

 

(Bottom)

Earth terminal

the chilly area.

 

 

(Lower section of the side)

When the outdoor unit is hung on the

 

 

ceiling, install the bush and drain pipe

 

 

 

 

 

MODEL NAME AND DIMENSIONS

 

 

on the drain port and drain water.

 

 

 

 

 

MODEL

 

WIDTH (mm)

HEIGHT (mm)

DEPTH (mm)

RAS-18FH6, RAS-25FH6, RAS-35FH6

780

 

280

220

RAC-18YH6, RAC-25YH6

700

 

505

258

 

RAC-35YH6

 

750

 

548

288

– 4 –

NAMES AND FUNCTIONS OF EACH PART

INDOOR UNIT INDICATIONS

 

FILTER LAMP (Green)

 

When the device is operated for a total of about 200

 

hours, the FILTER lamp lights indicates that it is time

POWER SWITCH

to clean the filter.The lamp goes out when the

“ (AUTO SWING)” button is pressed while the

 

 

operation is stopped.

 

OPERATION LAMP (Yellow)

 

This lamp lights during operation.

 

The OPERATION LAMP flashes in the following

 

cases during heating.

 

(1)

During preheating

 

 

For about 2-3 minutes after starting up.

 

(2)

During defrosting

 

 

Defrosting will be performed about once an hour

 

 

when frost forms on the heat exchanger of the

 

 

outdoor unit, for 5-10 minutes each time.

 

TIMER LAMP (Orange)

 

This lamp lights when the timer is working.

TEMPORARY SWITCH

Use this switch to start and stop when the remote controller does not work.

This temporary operation will be at the most recent setting made. (The unit will immediately go into automatic operation once power is switched on.)

CAUTION

Turn off the circuit breaker or pull out the power plug if the unit is not be operated for a long period.

If the power stays on and the unit is not operated, power is slightly consumed in the control circuit. The power is saved by turning off the power switch (or the circuit breaker when the power is supplied from the outdoor unit).

Attaching the air cleansing and deodorizing filters (Accessories) to the filter frame.

Attach the air cleansing and deodorizing filters to the frame by

 

 

gently compress its both sides and release after insertion into

 

 

filter frame.

 

The cooling capacity is slightly weakened and the cooling speed

 

 

becomes slower when the air cleansing and deodorizing filters

 

 

are used.

Frame

Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum cleaner or water rinse under running tap water. When you want to renew it, please ask your sales agent. Optional air cleansing and deodorizing filters(SPX-CFH11).

ENGLISH

– 5 –

HITACHI RAS-35FH6 User Manual

NAMES AND FUNCTIONS OF EACH PART

REMOTE CONTROLLER

This controls the operation of the indoor unit.

The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter, in some cases, the control signal may not be received.

This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.

Handle the remote controller with care.

Dropping it or getting it wet may compromise its signal transmission capability.

After new batteries are inserted into the remote controller, the unit will initially require approximately 10 seconds to respond to commands and operate.

Signal emitting window/transmission sign

Point this window toward the indoor unit when controlling it. The transmission sign blinks when a signal is sent.

Display

This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.

START/STOP button

Press this button to start operation. Press it again to stop operation.

AUTO SWING button

Controls the angle of the horizontal air deflector.

FAN SPEED selector

This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW) to (SILENT). (This button allows selecting the optimal or preferred fan speed for each operation mode.)

SLEEP button

Use this button to set the sleep timer.

TEMPERATURE buttons

Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)

TIME button

Use this button to set and check the time and date.

RESET button

Press this button after the batteries are replaced or when some irregular operation is found.

FUNCTION selector

Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to (COOL) and to (FAN) cyclically.

FAN SPEED selector

AUTO SWING button

TIMER control

Use these buttons to set the timer.

OFF-TIMER button Select the turn OFF time. ● ON-TIMER button Select the turn ON time. ● RESERVE button Time setting reservation. ● CANCEL button Cancel time reservation.

Precautions for Use

• Do not put the remote controller in the following places.

• In direct sunlight

• In the vicinity of a heater.

• Handle the remote controller carefully. Do not drop it on the floor, and protect it from water.

• Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again).

This is to protect the device and does not indicate a failure.

• If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection.

– 6 –

Loading...
+ 14 hidden pages