1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most

outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling. The 6” downrod (supplied) must be used for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This fan is suitable for use with solid-state speed controls.

WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UC7067RC, manufactured by Rhine Electric Co., Ltd.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

2

BP7307 Larissa KF220 1/9/06 8:36 AM Page 3

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver One wire stripper

One stepladder

Seven wire connectors (supplied) Three 40-watt (maximum) Candelabra

bulbs

Materials

Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

!WARNING

Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 10). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor and housing assembly

b.One coupling cover

c.One ceiling cover

d.Five blade flanges

e.Five fan blades

f.One switch cup assembly

g.One hanger bracket

h.One hanger ball/downrod (18”) assembly

i.One 6” downrod

j.One lower glass

k.One decorative ring/light fitter assembly

l.One decorative cap

m.One finial nut

n.Three downrod scrolls

o.One scroll collar assembly

p.One Fan/Light Wall Control (transmitter and receiver)

3

Emerson KF220GLZ00, KF220AGW00 Manual

BP7307 Larissa KF220 1/9/06 8:36 AM Page 4

q.One loose parts bag containing:

1.Two 1-1/4” threaded studs

2.Two knurled knobs

3.Two lockwashers

4.Seven wire connectors

5.One clevis pin/hairpin clip assembly

6.Eleven 1/4-20 x 13mm oval head screws

7.Sixteen 10-24 x 8mm pan head screws

8.Sixteen flat washers

9.Three 8-32 x 7mm pan head screws

10.Two 1/8-27 nuts

11.One 1/8-27 lockwasher

12.One metal washer

13.One rubber washer

14.One hex wrench

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.

2. Remove the fan motor and housing assembly from the protective plastic bag. Place the fan assembly into the lower foam pad with the bottom of the motor facing up.

The lower foam pad serves as a holder for the fan during the first stages of assembly.

A

D

C B

G

E F

H

I

J

K L

M

N P

O Q

EMERSON

4

BP7307 Larissa KF220 1/9/06 8:36 AM Page 5

Electrical Requirements

Ceiling Fan Procedures

IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Wall Control supplied with the fan, or an optional Emerson Electric SR100 Remote Control.

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse or circuit breaker box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

General

Your Emerson ceiling fan comes supplied with a Fan/Light Wall Control which consists of a wall control (transmitter) and a remote control receiver mounted under the ceiling cover. This system allows you to regulate your ceiling fan speed and light intensity.

NOTE: An optional Emerson Electric SR100 Remote Control may also be used to control your ceiling fan.

How to Assemble Your Ceiling Fan

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

IMPORTANT: Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of Wall Control and Receiver” and “Installation of Wall Control”, page 13. These sections instruct you how to: a) Set the operating frequency of the fan/light wall control and the remote control receiver; and b) Install the fan/light wall control in the wall box. You will then be ready to proceed with the assembly and installation of your ceiling fan, as follows:

1. Mount the fan blades to the blade flanges using three 10-24 x 8mm pan head screws and three flat washers (screws and washers supplied) (Figure 1).

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

5

BP7307 Larissa KF220 1/9/06 8:36 AM Page 6

10-24 X 8mm PAN HEAD SCREW (3)

FLAT WASHER (3)

FAN

BLADE

BLADE FLANGE

Figure 1

2. Remove and discard the four shipping retainers securing the motor hub in the motor housing.

NOTE: Take care not to scratch the fan housing when installing the blade assemblies.

3. Insert an 1/4-20 x 13mm oval head screw (supplied) into each of the two recessed holes in one of the blade flanges.

4. Rotate the motor hub so that two threaded holes line up with the two notches in the switch cup plate (Figure 2). Position the blade flange on the motor hub so that the screws in the blades flange align with the two threaded holes in the motor hub. Loosely tighten the screws at this time. Repeat this procedure for the remaining four blade assemblies.

5. Gently snug all flange screws to the motor hub, working around the hub in a clockwise sequence. Next, securely tighten all flange screws, again working in a clockwise sequence. Failure to follow this procedure could result in fan wobble. This completes the blade installation.

NOTE: If you wish to assemble your ceiling fan without the lower light installed, skip steps 6 and 7, and proceed to install the switch cup assembly in accordance with steps 8 and 9.

6.Remove the plastic plug from the center hole in the switch cup assembly.

Pass the two light fitter wires through the center hole, then screw the switch cup assembly onto the light fitter threaded nipple (Figure 3). Install a lockwasher and 1/8-27 nut (supplied) on the threaded nipple to secure the switch cup assembly to the decorative ring/light fitter assembly

DECORATIVE RING/LIGHT

FITTER ASSEMBLY

 

WHITE WIRE

WHITE WIRE

SWITCH CUP

ASSEMBLY

BLUE

 

WIRE

1/8-27 NUT &

 

LOCKWASHER

BLACK WIRE

LIGHT

 

FITTER

SWITCH CUP PLATE

Figure 3

 

NOTCH

1/4-20 x 13mm OVAL HEAD SCREWS (2) BLADE

FLANGE

MOTOR HUB

7. Connect the white wire from the light fitter to the white wire in the switch cup assembly (Figure 3). Connect the black wire from the light fitter to the blue wire in the switch cup.