Danfoss SWRO Service guide

0 (0)
Danfoss SWRO Service guide

Service Guide

SWRO plants working with

APP pumps and iSave ERDs

Trouble shooting guide

hpp.danfoss.com

Service Guide | APP pump and iSave ERD in SWRO plant

Table of Contents

Table of Contents

 

 

 

 

1.

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. .

.

2

 

2.

Seawater desalination system - terms of understanding . . . . . . . . . . . . . .

.

.

.3

 

3.

What does the APP high-pressure pump do . . . . . . . . . . . . . . . . . . . .

.

.

.4

 

4.

What does the iSave ERD do . . . . . . . . . . . . . . . . . . . . . . . . . . .

. .

.

5

 

5.

What does the LP-out flow control valve do . . . . . . . . . . . . . . . . . . . .

.

.

.6

 

6

Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.

.

.7

 

6.1

Permeate production decrease . . . . . . . . . . . . . . . . . . . . . . . . . .

.

.

.7

 

6.2

Membrane feed pressure decreases / increases . . . . . . . . . . . . . . . . . .

. .

.

8

 

6.3

LP-in seawater flow decreases / increases . . . . . . . . . . . . . . . . . . . . .

.

.

.9

 

6.4

LP-in seawater pressure decreases / increases . . . . . . . . . . . . . . . . . . .

.

.

10

 

6.5

LP-out brine water flow increase . . . . . . . . . . . . . . . . . . . . . . . . .

. .

. 11

 

6.6

High Amp / overload at iSave VFD . . . . . . . . . . . . . . . . . . . . . . . .

. .

.12

 

6.7

High Amp / overload at APP pump VFD . . . . . . . . . . . . . . . . . . . . . .

.

.

13

1. Introduction

This document gives a good understanding how

Information specific on the individual APP and

the SWRO plant works together with APP pump

iSave must be found in the Data sheets or Oper-

 

 

and iSave energy recovery device.

ating guides (IOM).

 

Explain the function of each main product.

 

 

Explain how the SWRO plant reacts when

 

 

 

main products get adjusted.

 

 

Trouble shooting guide with possible causes

 

 

 

and actions.

 

APP pumps

Danfoss APP pumps are positive displacement pumps with axial pistons that move a fixed amount of water in each cycle. Flow is proportional to the number of input shaft revolutions (rpm). Unlike centrifugal pumps, they produce the same flow at a given speed no matter what the discharge pressure is.

The design of the APP pump ensures lubrication of the moving parts by the fluid itself.

iSave energy recovery device

The iSave consists of an isobaric pressure exchanger, a high-pressure positive displacement booster pump and an electric motor.

The isobaric pressure exchangers are based on the technology used in the Danfoss APP pumps, and the high-pressure booster pumps are based on the vane pump principle enabling a very light and compact design.

The design of the iSave ensures lubrication of the moving parts by the fluid itself.

2

AX368834229417en-000201 | 02.2021

Service Guide | APP pump and iSave ERD in SWRO plant

2.Seawater desalination system - terms of understanding

 

 

 

 

RO membrane

Permeate

 

HP feed

 

6 HP membrane feed

 

 

 

 

 

 

 

8

 

HP feed

 

 

HP membrane brine flow

 

4

 

 

 

 

 

7

 

 

 

 

ERD loop flow

 

 

 

 

 

 

 

1

 

 

 

iSave

APP high-pressure pump

5

HP feed

 

 

 

feed

 

iSave

LP-out brine flow

 

 

 

 

2

 

 

 

LP-in feed

3

 

 

 

 

 

 

 

 

 

 

Flow control

 

 

 

 

valve

 

Clean fresh

 

 

 

Brine/Concentrate

 

 

 

9

 

seawater

 

 

 

 

 

 

Feed pump

 

 

Low Pressure seawater feed flow to high-pressure pumpLow Pressure seawater feed flow to iSave ERD (LP-in)

Low Pressure brine flow from iSave ERD (LP-out)High Pressure flow from pump to membrane

High Pressure flow from iSave ERD to membrane (HP-out)High Pressure total flow to membrane (+ )

High Pressure brine flow from membrane (HP-in)Permeate flow from membrane

Brine/concentrate flow

Items

Description

 

 

High Pressure flow from iSave ERD to membrane (HP-out)

 

High Pressure total flow to membrane (+ )

ERD loop flow (membrane cross flow)

High Pressure brine flow from membrane (HP-in)

 

 

 

High Pressure total flow to membrane

Membrane recovery rate - the % recovery is defined as the

ratio of permeate flow rate (8) divided by the membrane

Permeate flow from membrane

feed flow rate (6).

 

 

Example: (100 m3/250 m3) x 100 = 40%

AX368834229417en-000201 | 02.2021

3

Service Guide | APP pump and iSave ERD in SWRO plant

3.What does the APP high-pressure pump do

Flow from the high-pressure pump makes the permeate production.

 

 

 

 

RO membrane

Permeate

 

HP feed

 

6 HP membrane feed

 

 

 

 

 

 

 

8

 

HP feed

 

 

HP membrane brine flow

 

4

 

 

 

 

 

7

 

 

 

 

 

 

 

1

 

 

 

iSave

APP high-pressure pump

5

HP feed

 

 

 

feed

 

iSave

LP-out brine flow

 

 

 

 

2

 

 

 

LP-in feed

3

 

 

 

 

 

 

 

 

 

 

Flow control

 

 

 

 

valve

 

Clean fresh

 

 

 

Brine/Concentrate

 

 

 

9

 

seawater

 

 

 

 

 

 

Feed pump

 

Lorem ipsum

Action

Result

 

 

Increase HP pump speed

Raise system pressure (6) and permeate flow (8)

 

 

Decrease HP pump speed

Lower system pressure (6) and permeate flow (8)

 

 

Changing the HP pump speed

Does not change the ERD loop flow (5 and 7)

 

 

4

AX368834229417en-000201 | 02.2021

Service Guide | APP pump and iSave ERD in SWRO plant

4.What does the iSave The iSave controls the ERD loop flow (5, 6 and 7).

ERD do

The iSave exchanges brine flow with new seawa-

 

ter, transfers the brine pressure into booster

pump and sends new seawater into membrane feed.

 

 

 

 

RO membrane

Permeate

 

HP feed

 

6 HP membrane feed

 

 

 

 

 

 

 

8

 

HP feed

 

 

HP membrane brine flow

 

4

 

 

 

 

 

7

 

 

 

 

ERD loop flow

 

 

 

 

 

 

 

1

 

 

 

iSave

APP high-pressure pump

5

HP feed

 

 

 

feed

 

iSave

LP-out brine flow

 

 

 

 

2

 

 

 

LP-in feed

3

 

 

 

 

 

 

 

 

 

 

Flow control

 

 

 

 

valve

 

Clean fresh

 

 

 

Brine/Concentrate

 

 

 

9

 

seawater

 

 

 

 

 

 

Feed pump

 

 

Action

 

Result

 

 

 

 

 

 

Increase iSave speed

 

Higher membrane loop flow (5 and 7) - lowers membrane recovery rate

 

 

 

 

Decrease iSave speed

 

Lower membrane loop flow (5 and 7) - raises membrane recovery rate

 

 

 

 

Changing the iSave speed

 

Does not effect the LP feed flow (2 and 3) and the permeate flow (8)

 

 

 

 

 

 

 

 

 

Section view of iSave

 

 

 

 

 

 

HP-in

 

High-pressure

Pressure exchanger

 

 

booster pump

 

 

 

HP-out

 

 

 

 

 

LP-in

LP-out

 

 

 

 

 

 

AX368834229417en-000201 | 02.2021

5