Danfoss TT2.5F Standard Data sheet

5 (2)
Danfoss TT2.5F Standard Data sheet

TT2.5F

Standard Compressor

R134a

115V 60Hz

General

Code number

 

 

 

 

102G3248

 

 

Approvals

 

 

 

 

UL984

 

 

Compressors on pallet

 

 

 

 

125

 

 

Application

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

MBP

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Evaporating temperature

 

°F

 

 

 

-13 to 23

Voltage range

 

V

 

 

 

103 - 127

Max. condensing temperature continuous (short)

°F

 

 

 

140 (158)

Max. winding temperature continuous (short)

°F

 

 

 

257 (257)

Cooling requirements

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Application

 

 

LBP

MBP

HBP

 

LBP

MBP

HBP

90°F

 

 

 

S

100°F

 

 

 

S

110°F

 

 

 

S

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

RSIR

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

 

 

 

5.1

 

Cut in Current, HST | LST

 

A

 

 

 

 

14.0

 

Resistance, main | start winding (77°F)

 

8.1

 

 

 

4.9

 

Design

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

0.16

 

 

Oil quantity (type)

 

fl.oz.

 

6.1 (polyolester)

 

Maximum refrigerant charge

 

oz.

 

 

14.0

 

 

Free gas volume in compressor

 

fl.oz.

 

 

54.2

 

 

Weight without electrical equipment

lbs.

 

 

14.7

 

 

Dimensions

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

6.22

 

 

 

 

 

B

 

5.98

 

 

 

 

 

B1

 

 

 

 

 

 

 

B2

 

 

 

 

Suction connector

location, I.D. in. | angle

C

0.252-0.259 | 30°

 

 

material | comment

Cu-plated steel | Rubber plug

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 31.5°

 

 

material | comment

Cu-plated steel | Rubber plug

Discharge connector

location, I.D. in. | angle

E

0.189-0.193 | 28°

 

 

material | comment

Cu-plated steel | Rubber plug

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

material | comment

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

June 2012

Manufactured by Secop for Danfoss - DEHC.ED.401.Q7.22 / 520N1363

1/2